Ac current sensor & over-current protector (6 pages)
Summary of Contents for Infinite L-com SRAQ-D681-B
Page 1
LASER DUST / PARTICULATE SENSOR MODULE User Guide for SRAQ-D681-B Product Description The SRAQ-D681-B is a particle concentration sensor that uses the principle of laser light scattering (MIE scattering) to determine the number of particulate matter suspended in the air. The sensor can detect and calculate the presence of various sized particles ranging from 0.3 µm to 10 µm in diameter.
Page 2
Technical Parameters Parameter Index Unit Measuring particle diameter 0.3~1.0 1.0~2.5 2.5~10 µm Counting efficiency 50%·0.3 µm 98%@>= 0.5 µm Standard volume Response time ≤10 Working voltage 5 VDC Maximum operating current Standby current ≤200 µA Data interface level L<0.8@3.3 H>2.7@3.3 Working temperature range -20~50 °C...
Page 3
Digital Interface Data interface: 2 pin for the serial data communication interface, the use of universal asynchronous receiver and receiver (UART); 1 pin fo r the control signal interface, the use of high and low level control, all the high average 3.3VTTL level. Interface pin definition: PIN1 DC5V...