SPECIFICATION
selec
FEATURES
Ø
AC 100 - 240 V Wide-range Input.
Ø
Cost optimized without compromising quality or reliability.
0
0
Ø
Full power between - 25 C and + 50 C.
Ø
Compact size.
Plastic case, Ultra slim.
Ø
Support wide range of AC / DC auxiliary supply.
Ø
Ø
Efficiencies up to 82 %.
Ø
Protection against short circuit, overload.
Ø
Cooling by free air convection.
Ø
INTENDED USE
This device is designed for installation in an enclosure and is intended for the
general professional use such as in
instrumentation equipment, office,
i
ndustrial control
and
communication.
Do not use this power supply in equipment where malfunction may cause
severe personal injury or threaten human life.
SAFETY INSTRUCTION
RPS15-05-CE
INPUT SPECIFICATIONS
Bedienungsanleitung
INPUT VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY ( TYP. )
AC CURRENT ( TYP. )
INRUSH CURRENT
( TYP. )
START UP TIME
OUTPUT SPECIFICATIONS
OUTPUT VOLTAGE
OUTPUT CURRENT
RIPPLE AND NOISE
LINE AND LOAD REGULATION
HOLD UP TIME
SERIES OPERATION
Ripple & Noise measured at 20 MHz of bandwidth by using 0.1uf &10uf parallel capacitor.
PROTECTIONS
INPUT FUSED
OUTPUT OVER LOAD
OUTPUT SHORT CIRCUIT
ENVIRONMENT
OPERATING TEMPERATURE
STORAGE TEMPERATURE
COOLING
HUMIDITY
ALTITUDE
VIBRATION
SAFETY & EMC
SAFETY STANDARDS
DIELECTRIC WITHSTAND
VOLTAGE
INSULATION RESISTANCE
CONDUCTED EMISSION
RADIATED EMISSION
EMS IMMUNITY
100 - 240 VAC ( 141 - 340 VDC )
50 / 60 Hz
≥ 76 % @ 230 VAC
0.3 A @ 115 VAC; 0.15 A @ 230 VAC
< 30 Amps; Measured at 264 VAC,
25 C Ambient, Cold Start
0
<
1
Sec, Full Load
4.5 to 5.5 VDC
2.4 A at 5 VDC
< 1.5 % of Vout
± 1 %
30 ms @ 230 VAC & 10 ms @ 115 VAC, Full Load
Possible for up to two power supplies
( with external diode )
1.25 A - 250 VAC Internal
110 % to 150 % of rated output current
Protection type: Hiccup mode; recovers
automatically after fault condition is removed.
Hiccup mode when output is shorted; Recovers
automatically after fault condition is removed.
- 40 C to + 70 C; De-rate linearly above 50 C from
0
0
0
0
0
100 % load at 50 C to 50 % load at 70 C.
Note: Only start up guaranteed at - 40 C with spec
0
deterioration.
0
0
- 40 C to + 85 C
Natural Cooling
5 to 95 % RH, Non Condensing
2000 m
~
Component: 10
500 Hz, 2 G 10 min. / cycle,
period for 60 min. each along X, Y, Z axes.
Designed to meet IEC 62368-1
I/P to O/P: 4000 VAC
100 M min. ( between all outputs and all inputs /
Ω
PE terminals ) at 500 VDC
CISPR32; Class B
CISPR22; Class A
Compliance to IEC61000 -4-4,5,11
DIMENSIONAL DIAGRAM
DIMENSION
17.5 mm x 90 mm x 65 mm ( W x H x D )
WEIGHT
< 100 gms
17.50
4.30
90 90
WIRING DIAGRAM
V+
V-
DC ON
Vo ADJ.
selec
L
N
WIRING INSTRUCTIONS
1. To prevent risk of electric shock, power supply equipment must be
kept OFF while wiring.
2. Terminals and electrically charged parts must not be touched when
the power is ON.
3. Wiring shall be done strictly according to terminal layout provided
in the operating manual.
Doc. name: OP INST RPS15-05-CE OP2057 - V01 ( Page 1 of 2 )
64.35
64.35

Advertisement

loading
Need help?

Need help?

Do you have a question about the RPS15-05-CE and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Selec RPS15-05-CE

  • Page 1 PE terminals ) at 500 VDC in the operating manual. CONDUCTED EMISSION CISPR32; Class B SAFETY INSTRUCTION RADIATED EMISSION CISPR22; Class A Compliance to IEC61000 -4-4,5,11 EMS IMMUNITY Doc. name: OP INST RPS15-05-CE OP2057 - V01 ( Page 1 of 2 )
  • Page 2 Minor electric shock, fire or product failure may occasionally occur. Do not allow any pieces of metal or conductors or any clippings or cuttings resulting from installation work to enter Fig. 3 the product. Doc. name: OP INST RPS15-05-CE OP2057-V01 ( Page 2 of 2 )