EIP F2000P-TH-K02-WT User Manual

Humidity & temperature controller – external sensor

Advertisement

Quick Links

Important safety information Warning
Always turn off power before installing, remove, cleaning controller.
Read all of the information in this manual before installing the controller.
Notice of the supply power voltage of the controller:
Do not confuse them and do not install the controller over the voltages range.

Mounting and Wiring Diagram

Find the two ears which are on both sides of the controller, press them to take off the main part from the base part.
Mount the base part on the wall firstly: Mark the place of mounting holes. Mount controller on the
wall, 1.2-1.3 meter above the floor. Do not behind a door, in a corner, near diffuser, in direct sunlight, or near any heat or
steam generating fixtures. See Fig 1. There are two dimensions available.
Connect wires to terminal strip. See the wiring diagrams fig.2. Make sure wiring connections correct and secure.
Finally install the main part on the base part.

Buttons and LCD Display

turn on/off
down
cool/heat switch

Operation

1. Press the power button for 2 seconds to turn on the controller. The measurement humidity displays on the below line of
LCD and the measurement temperature displays on the upper line of LCD. Also ROOM symbol displays on the left.
2. switch button: Use to select humidity or temperature setting. Press switch to select which value can be set now
(humidity or temperature). When selecting, relevant number is blinking and you may set the value with pressing ▼ or ▲
button.
3. Setting humidity: Measurement range and setting range of humidity is 0~100%RH/0~100%RH. Press ▼ or ▲ button
for humidity setting and each press will change 0.1%RH. Continuously press ▼ or ▲ button to adjust the value quickly.
When adjusting, the symbol of humidity number will blink, which means that the setting is not confirmed. After blinking for
6 seconds, the setting is confirmed and then it returns to display measured humidity.
humidifier/dehumidifier on working.
4.
Setting temperature: Measurement range and setting range of temperature is 0℃~60℃(32.0~140℉)/5~35℃
(41.0~95.0℉). Press ▼ or ▲ button for temperature setting and each press will change 0.1℃(0.1℉). Continuously
Humidity & Temperature Controller – External Sensor
110VAC
Fig.2
humidifying
dehumidifying
setting switch
up
disappearing indicates humidifier/dehumidifier stops working.
ON
Page 1 of 2
Model No. F2000P-TH-K02(-WT)-(B)
lock mode
cooling/heating
temperature
ROOM
AUTO
SET
lock mode
humidity
ON
Part No. 3035162
User's Manual
C
Fig.1 base board
lock temp
temp. device on
RH device on
appearing on LCD indicates

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the F2000P-TH-K02-WT and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for EIP F2000P-TH-K02-WT

  • Page 1 Part No. 3035162 Model No. F2000P-TH-K02(-WT)-(B) Humidity & Temperature Controller – External Sensor User’s Manual Important safety information Warning  Always turn off power before installing, remove, cleaning controller.  Read all of the information in this manual before installing the controller. ...
  • Page 2 press ▼ or ▲ button to adjust the value quickly. When adjusting, the number of temperature blinks, which means that the setting is not confirmed. After blinking for 6 seconds, the setting is confirmed and then it returns to display measured temperature.

This manual is also suitable for:

F2000p-th-k02-b

Table of Contents