EIP F2000P-TH-K02-a(B) User Manual

Humidity & temperature controller – internal sensor

Advertisement

Important safety information Warning

Always turn off power before installing, remove, cleaning controller.
Read all of the information in this manual before installing the controller.
Notice of the supply power voltage of the controller: 110VAC
Do not confuse them and do not install the controller over the voltages range.

Mounting and Wiring Diagram

Find the two ears which are on both sides of the controller, press them to take off the
main part from the base part.
Mount the base part on the wall firstly: Mark the place of
Mount controller on the wall, 1.2-1.3 meter above the floor.
in
a corner, near diffuser, in direct sunlight, or near any
generating fixtures. See Fig 1. There are two dimensions
Connect wires to terminal strip. See the wiring diagrams
connections correct and secure.
Finally install the main part on the base part.

Buttons and LCD Display

turn on/off
down
cool/heat switch

Operation

1. Press the power button for 2 seconds to turn on the controller. The measurement humidity displays on the below line of
LCD and the measurement temperature displays on the upper line of LCD. Also ROOM symbol displays on the left.
2. switch button: Use to select humidity or temperature setting. Press switch to select which value can be set now
(humidity or temperature). When selecting, relevant number is blinking and you may set the value with pressing ▼ or ▲
button.
3. Setting humidity: Measurement range and setting range of humidity is 0~100%RH/0~100%RH. Press ▼ or ▲ button
for humidity setting and each press will change 0.1%RH. Continuously press ▼ or ▲ button to adjust the value quickly.
When adjusting, the symbol of humidity number will blink, which means that the setting is not confirmed. After blinking for
6 seconds, the setting is confirmed and then it returns to display measured humidity.
humidifier/dehumidifier on working.
4. Setting temperature: Measurement range and setting range of temperature is 0℃~60℃(32.0~140℉)/5~35℃(41.0~95.0
℉). Press ▼ or ▲ button for temperature setting and each press will change 0.1℃(0.1℉). Continuously press ▼ or ▲
button to adjust the value quickly. When adjusting, the number of temperature blinks, which means that the setting is not
confirmed. After blinking for 6 seconds, the setting is confirmed and then it returns to display measured temperature.
appearing on right of the LCD indicates cooling/heating device on working.
cooling/heating device stops working.
5. set button : Use to select cooling or heating mode for temperature control . In cooling,
Humidity & Temperature Controller – Internal Sensor
humidifying
dehumidifying
setting switch
up
disappearing indicates humidifier/dehumidifier stops working.
ON
Page 1 of 2
Model No. F2000P-TH-K02-a(B)
lock mode
cooling/heating
temperature
ROOM
AUTO
SET
lock mode
humidity
ON
Part No. 3035160
User's Manual
C
Fig.1 base board
110vac
mounting holes.
Do not behind a door,
heat or steam
available.
fig.2. Make sure wiring
Fig.2
lock temp
temp. device on
RH device on
appearing on LCD indicates
disappearing indicates s
symbol appears on the top left

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the F2000P-TH-K02-a(B) and is the answer not in the manual?

Questions and answers

Summary of Contents for EIP F2000P-TH-K02-a(B)

  • Page 1 Part No. 3035160 Model No. F2000P-TH-K02-a(B) Humidity & Temperature Controller – Internal Sensor User’s Manual Important safety information Warning  Always turn off power before installing, remove, cleaning controller.  Read all of the information in this manual before installing the controller. ...
  • Page 2 of LCD. In heating, symbol appears on the top left of LCD. Press set button for 6 seconds until appearing. It indicates that the cooling/heating mode is locked. Now the working mode can not be changed. Lock the set point: Press ▼and ▲ at the same time for about 6 seconds until the symbol appearing on the top right of LCD, which indicates that the set points of humidity and temperature are locked, after that, it’s impossible to adjust humidity or temperature by ▼and ▲button.

Table of Contents