Table 2-1. Acceptance Check
Step
Control
Position/Operation
Observe at 50SJ OUT
1
FREQMULT
X 1 (Model 180)
X .1 (Model 180LF)
1 Hz, 10V p-p sine wave (Model 180)
0.1 Hz, 10V p-p sine wave (Model 180LF)
2
FREQ MULT
X 1, X 10, X 100, - - - X 1M
(as applicable)
Frequency increases by a decade for every change of
switch position
3
FREQ MULT
X IK
4
Function
Triangle wave
5
Function
"b
Square wave
6
AMPLITUDE
ccw
Decrease in waveform amplitude
7
DC OFFSET
cw
Positive slew of waveform from full negative offset
8
DC OFFSET
ccw
Negative slew of waveform
g
DC OFFSET
OFF
10
AMPLITUDE
Full cw
11
Dial
Full cw
12
SWEEP WIDTH
Full cw
Frequency of waveform repetitively sweeps
2-2