Scholl 27100 Instructions For Use Manual

Heating bridge
Table of Contents

Advertisement

Quick Links

GBA B 1010 0 E
Instructions for Use
Heating bridge
Model-No.
27100, /HS, /D, /D/HS 2, 4
27110, /HS, /D, /D/HS 2, 4
27120, /HS, /D, /D/HS 3, 6
27130, /HS, /D, /D/HS 3, 6
27140, /HS, /D, /D/HS 3, 6
27150, /HS, /D, /D/HS 4, 8
27160, /HS, /D, /D/HS 4, 8
27170, /HS, /D, /D/HS 4, 8
27180, /HS, /D, /D/HS 5, 10
27190, /HS, /D, /D/HS 5, 10
27200, /HS, /D, /D/HS 5, 10
Scholl Apparatebau GmbH & Co. KG
Zinhainer Weg 4
D–56470 Bad Marienberg/Germany
Phone
+0049 (0) 2661 – 9868-10
Fax
+0049 (0) 2661 – 9868-38 (Service)
Internet
www.scholl-gastro.de
E-mail
info@scholl-gastro.de
BA
Last revised 04-2016
1-tier
Radiators Art. No.
B 1010
B 1020
B 1030
B 1040
B 1050
B 1060
B 1070
B 1080
B 1090
B 1100
B 1110
Page 1 of 34
cough
protection
1-tier
2-tier
Art. No.
Art. No.
B 1012
B 1014
B 1022
B 1024
B 1032
B 1034
B 1042
B 1044
B 1052
B 1054
B 1062
B 1064
B 1072
B 1074
B 1082
B 1084
B 1092
B 1094
B 1102
B 1104
B 1112
B 1114
cough
protection
2-tier
Art.No.
B 1016
B 1026
B 1036
B 1046
B 1056
B 1066
B 1076
B 1086
B 1096
B 1106
B 1116
April 15, 2016
Rev. 0

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 27100 and is the answer not in the manual?

Questions and answers

Summary of Contents for Scholl 27100

  • Page 1 1-tier 1-tier 2-tier 2-tier Model-No. Radiators Art. No. Art. No. Art. No. Art.No. 27100, /HS, /D, /D/HS 2, 4 B 1010 B 1012 B 1014 B 1016 27110, /HS, /D, /D/HS 2, 4 B 1020 B 1022 B 1024 B 1026...
  • Page 2: Table Of Contents

    GBA B 1010 0 E ABLE OF CONTENTS Table of contents ............................... 2 Preface ................................4 Conventions ............................... 5 Pictograms – General safety notes ....................5 Pictograms – Warning notes ......................7 Pictograms – Important notes ......................8 Product information ..........................9 Execution ............................
  • Page 3 GBA B 1010 0 E Troubleshooting ............................16 Possible malfunctions ........................17 Data ................................. 18 Technical data ..........................18 8.1.1 Technical data heating bridge 1-tier ..................18 8.1.2 Technical data heating bridge 2-tier ..................19 Dimensioned drawing ........................20 8.2.1 Dimensioned drawing heating bridge 1-tier ................
  • Page 4: Preface

    REFACE Congratulations! In purchasing this new SCHOLL appliance you have chosen a product which meets highest technical stand- ards while providing outstanding convenience in practical use. This appliance has been designed with minimal energy consumption in mind. Used responsibly, it will serve you well in an ecologically sound manner.
  • Page 5: Conventions

    GBA B 1010 0 E ONVENTIONS – G ICTOGRAMS ENERAL SAFETY NOTES Be sure to observe these Instructions for Use as well as the safety notes to prevent injuries or damage to health or property. Do not alter or modify this appliance. Never use a defective appliance.
  • Page 6 GBA B 1010 0 E Do not touch the surfaces of the appliance. The surfaces of this appliance may get hot. Please allow the unit to cool down fully before cleaning or stowing it. Never cover this appliance. Burn injury or fire hazard! Caution: Do look into the light source! Risk of eye damage!
  • Page 7: Pictograms - Warning Notes

    GBA B 1010 0 E – W ICTOGRAMS ARNING NOTES Cleaning must only be performed by qualified persons who have read and under- stood these Instructions for Use and are familiar with applicable hygiene rules. En- sure that care is exercised during cleaning of the unit. For light cleaning, wipe down the surface with a cloth or soft brush/sponge soaked in warm water which contains a small amount of dishwashing detergent.
  • Page 8: Pictograms - Important Notes

    GBA B 1010 0 E – I ICTOGRAMS MPORTANT NOTES DANGER indicates an immediately threatening hazard. Failure to observe this warning notice will result in severe physical injury or death. WARNING indicates a potentially dangerous situation. Failure to observe this warning notice may result in severe physical injury or death.
  • Page 9: Product Information

    GBA B 1010 0 E RODUCT INFORMATION The heating bridge may only be used to keep dishes short-term warm. XECUTION 2.1.1 E XECUTION HEATING BRIDGE TIER Heating bridge with:  Casing and feet made of chrome nickel steel 18/10  All sizes available as transportable design or for fixed mounting ...
  • Page 10: Information Regarding Compliance With Standards, Laws And Directives

    GBA B 1010 0 E NFORMATION REGARDING COMPLIANCE WITH STANDARDS LAWS AND DIRECTIVES This appliance conforms to the following: Standards, laws, directives 2006/95/EG Low Voltage Directive AFETY This appliance conforms to accepted technical rules and relevant safety codes. However, proper use of the appliance is a prerequisite for effectively preventing damage or accidents.
  • Page 11: Packing, Transport, Intermediate Storage, Scope Of Delivery

    GBA B 1010 0 E ACKING TRANSPORT INTERMEDIATE STORAGE SCOPE OF DELIVERY ACKING The type of packing employed will depend, to a large extent, on the adopted shipping mode and route. Except where otherwise agreed by contract, packing will conform to the "HPE Packing Guideline" defined by the German Federal Association of the Wooden Materials, Pallets and Export Packing Industry and by the German Engineering Federation.
  • Page 12: Installation And Electrical Installation

    GBA B 1010 0 E NSTALLATION AND ELECTRICAL INSTALLATION NSTALLATION Before the installation of the appliance, observe the following:  Inspect the unit for any defect or damage sustained in transit.  Check all screw connections for tightness.  Familiarize yourself with the Instructions for Use and with the conditions for the safe operation of this appliance.
  • Page 13: Operation

    GBA B 1010 0 E PERATION The heating bridge has a separate step switch for each tier. The heat lamps must be switched on/off by the step switch. NTENDED USE Practice:  Switch on the heat lamps with the step switch. ...
  • Page 14: Maintenance

    GBA B 1010 0 E AINTENANCE AINTENANCE AND REPAIR Maintenance and repairs on the appliance must only be carried out by an author- ized professional observing applicable safety regulations. Improperly executed work will put your safety at risk! Before any cleaning, maintenance or repair work is carried out, the appliance must be disconnected from the mains and de-energized.
  • Page 15 GBA B 1010 0 E For light cleaning, wipe down the surface with a cloth or soft brush/sponge soaked in warm water containing a small amount of dishwashing detergent. Follow this up by wiping with clear water until no cleaning agent residue remains on the surface, as the latter might cause discoloration or stains.
  • Page 16: Troubleshooting

    GBA B 1010 0 E ROUBLESHOOTING Repairs must be carried out by an authorized specialist in compliance with applica- ble safety codes and regulations. Improperly executed work will put your safety at risk! Note that some work must only be carried out by an electrical specialist. According to DIN EN 60204-1: 2011-01, specialists are „persons who by reason of their relevant training and experience are capable of recognizing risks and avoiding potential hazards."...
  • Page 17: Possible Malfunctions

    GBA B 1010 0 E OSSIBLE MALFUNCTIONS Malfunction Cause Remedy Heat lamp does not heat Defective plug/electrical cord DANGER! Hazardous electrical voltage. Pull out the mains plug and bar product from further use. To be remedied by an electrical specialist. Heat lamp does not heat IRK-Halogen-infrared-quartz- Exchange IRK-Halogen-infrared-...
  • Page 18: Data

    Heating zones to be switched individually  Height 435 mm Model-No. Art.-No. Length Radiators Voltage Power 27100, /HS B 1010, B 1012 1.000 mm 230 V 800 W 27110, /HS B 1020, B 1022 1.100 mm 230 V 800 W...
  • Page 19: Technical Data Heating Bridge 2-Tier

    Heating zones to be switched individually  Height 800 mm Model-No. Art.-No. Length Radiators Voltage Power 27100/D, /D/HS B 1014, B 1016 1.000 mm 230 V 1.600 W 27110/D, /D/HS B 1024, B 1026 1.100 mm 230 V 1.600 W...
  • Page 20: Dimensioned Drawing

    GBA B 1010 0 E IMENSIONED DRAWING 8.2.1 D IMENSIONED DRAWING HEATING BRIDGE TIER Model-No. Art. No. 27100 B 1010 Page 20 of 34 April 15, 2016 Last revised 04-2016 Rev. 0...
  • Page 21: Dimensioned Drawing Heating Bridge 1-Tier With Cough Protection

    GBA B 1010 0 E 8.2.2 D IMENSIONED DRAWING HEATING BRIDGE TIER WITH COUGH PROTECTION Model-No. Art. No. 27100/HS B 1012 Page 21 of 34 April 15, 2016 Last revised 04-2016 Rev. 0...
  • Page 22: Dimensioned Drawing Heating Bridge 2-Tier

    GBA B 1010 0 E 8.2.3 D IMENSIONED DRAWING HEATING BRIDGE TIER Model-No. Art. No. 27120/D B 1034 Page 22 of 34 April 15, 2016 Last revised 04-2016 Rev. 0...
  • Page 23: Circuit Diagram

    GBA B 1010 0 E IRCUIT DIAGRAM 8.3.1 C IRCUIT DIAGRAM HEATING BRIDGE TIER WITH HEAT LAMPS Model-No. Art. No. 27100, /HS B 1010, B 1012 27110, /HS B 1020, B 1022 Key: Step switch Indicator light E1-E2 IRK-Halogen-infrared-quartz-radiator Page 23 of 34...
  • Page 24: Circuit Diagram Heating Bridge 1-Tier With 3 Heat Lamps

    GBA B 1010 0 E 8.3.2 C IRCUIT DIAGRAM HEATING BRIDGE TIER WITH HEAT LAMPS Model-No. Art. No. 27120, /HS B 1030, B 1032 27130, /HS B 1040, B 1042 27140, /HS B 1050, B 1052 Key: Step switch Indicator light E1-E3 IRK-Halogen-infrared-quartz-radiator Page 24 of 34...
  • Page 25: Circuit Diagram Heating Bridge 1-Tier With 4 Heat Lamps

    GBA B 1010 0 E 8.3.3 C IRCUIT DIAGRAM HEATING BRIDGE TIER WITH HEAT LAMPS Model-No. Art. No. 27150, /HS B 1060, B 1062 27160, /HS B 1070, B 1072 27170, /HS B 1080, B 1082 Key: Step switch Indicator light E1-E4 IRK-Halogen-infrared-quartz-radiator Page 25 of 34...
  • Page 26: Circuit Diagram Heating Bridge 1-Tier With 5 Heat Lamps

    GBA B 1010 0 E 8.3.4 C IRCUIT DIAGRAM HEATING BRIDGE TIER WITH HEAT LAMPS Model-No. Art. No. 27180, /HS B 1090, B 1092 27190, /HS B 1100, B 1102 27200, /HS B 1110, B 1112 Key: Step switch Indicator light E1-E5 IRK-Halogen-infrared-quartz-radiator Page 26 of 34...
  • Page 27: Circuit Diagram Heating Bridge 2-Tier With 4 Heat Lamps

    GBA B 1010 0 E 8.3.5 C IRCUIT DIAGRAM HEATING BRIDGE TIER WITH HEAT LAMPS Model-No. Art. No. 27100/D, /D/HS B 1014, B 1016 27110/D, /D/HS B 1024, B 1026 Key: S1-S2 Step switch H1-H2 Indicator light E1-E4 IRK-Halogen-infrared-quartz-radiator Page 27 of 34...
  • Page 28: Circuit Diagram Heating Bridge 2-Tier With 6 Heat Lamps

    GBA B 1010 0 E 8.3.6 C IRCUIT DIAGRAM HEATING BRIDGE TIER WITH HEAT LAMPS Model-No. Art. No. 27120/D, /D/HS B 1034, B 1036 27130/D, /D/HS B 1044, B 1046 27140/D, /D/HS B 1054, B 1056 Key: S1-S2 Step switch H1-H2 Indicator light E1-E6 IRK-Halogen-infrared-quartz-radiator...
  • Page 29: Circuit Diagram Heating Bridge 2-Tier With 8 Heat Lamps

    GBA B 1010 0 E 8.3.7 C IRCUIT DIAGRAM HEATING BRIDGE TIER WITH HEAT LAMPS Model-No. Art. No. 27150/D, /D/HS B 1064, B 1066 27160/D, /D/HS B 1074, B 1076 27170/D, /D/HS B 1084, B 1086 Key: S1-S2 Step switch H1-H2 Indicator light E1-E8 IRK-Halogen-infrared-quartz-radiator...
  • Page 30: Circuit Diagram Heating Bridge 2-Tier With 10 Heat Lamps

    GBA B 1010 0 E 8.3.8 C IRCUIT DIAGRAM HEATING BRIDGE TIER WITH HEAT LAMPS Model-No. Art. No. 27180/D, /D/HS B 1094, B 1096 27190/D, /D/HS B 1104, B 1106 27200/D, /D/HS B 1114, B 1116 Key: S1-S2 Step switch H1-H2 Indicator light E1-E10 IRK-Halogen-infrared-quartz-radiator Page 30 of 34...
  • Page 31: Spare Parts List

    27200/D, /D/HS 73,80,71 high-temperature single core 1,5mm² green/yellow 73,80,72 high-temperature single core 1,5mm² white/black 73,80,73 high-temperature single core 1,5mm² blue 77,45,10 TSG panel for 27100 77,45,20 TSG panel for 27110 77,45,30 TSG panel for 27120 77,45,40 TSG panel for 27130 77,45,50...
  • Page 32: Disposal And Environmental Notes

    GBA B 1010 0 E ISPOSAL AND NVIRONMENTAL OTES The appliance has been packed before shipping to protect it against damage in transit. After unpacking, please dispose of packing materials in an environmentally sound manner. All packing materials are eco-compatible, 100% recyclable and marked with a sym- bol to that effect.
  • Page 33: Warranty And Service

    GBA B 1010 0 E ARRANTY AND SERVICE 10.1 W ARRANTY CONDITIONS The manufacturer accepts no liability or warranty in the following cases:  failure to observe notes and instructions given in the Instructions for Use;  use of the product in a manner not conforming to its intended use; ...
  • Page 34: Service Address

    7:00 a.m. till 4:00 p.m. Fridays from 7:00 a.m. till 12:15 p.m. Outside these office hours please communicate your requests per e-mail or telefax. Scholl Apparatebau GmbH & Co. KG Zinhainer Weg 4 D-56470 Bad Marienberg/Germany Phone 0049 (0)2661/9868-10...

Table of Contents