BHS-3000C Installation and Programming Instructions
• If siren is not used, disable supervision (Advanced j Device
Menu | Control Panel j Vw Edit | Alarm outputs j Supervised)
• Entry delay must not exceed 45 seconds. (Advanced Menu
| Account | Area | Zone j Vw/Edt Zone | Entry Delay Time)
Program each Entry/Exit Zone individually.
6.3.4 Related Installation and Wiring Method References
• Commercial Burg. - UL 681 ~ Installation and Classification
of Burglar and Holdup alarm systems.
• Commercial Burg. - UL611 - Standard for Central-Station
Burglar-Alarm systems.
• Residential Burg. - UL 1641 - Installation and Classification
of Residential Burglar Alarm Systems
• NFPA 70-1996
6.3.5 SIA Programmingllnstallation Guidelines
BHS-3000C, which is marked with the integral UL/SIA label,
complies with the Control Panel Standard ANSI/SIA CP-01-2000:
Features for False Alarm Reduction.
The panels come defaulted in the SIA mode and contain some
programming areas, which are not available in the Brinks Default
mode. Below are the default values.
Advanced Menu j Account Menu J Area Menu | Vw/Edt Area
Cross Zone Time: 20 seconds
Swinger Trips 5: 1
Automatic Swinger Reset5: Disabled
Restoral Minutes 5: Default is 5 minutes
Advanced Menu | Account Menu | Area Menu j Zone Menu J
Vw/Edt Zone
Cross Zone Enable: Disabled
Swinger Bypass 5: Enabled for Non-Fire zones, disabled for Fire
zones.
Fire Verification Enable: Disabled.
Dialer Delay Enable: Enabled for Non-Fire zones, Disabled for
Fire zones
Standard Menu
Exit Time: 60 seconds (Residential), 120 seconds (Commercial)
Entry Time: 30 seconds
Advanced Menu | Account Menu | Vw/Edt Acnt
Exit Time Restart: Enabled
Automatic Motion Off (Auto stay arm on unvacated premise
feature): Enabled (System automatically arms with Motions Off if
no Exit/Entry zone is opened during the Exit Delay countdown.)
Alarm Cancel: Enabled
Dialer Delay (Abort Window): 30 seconds
Double Dispatch: Enabled (Requires the user to press the Fire,
Medical, or Panic emergency key twice within three seconds to'
trigger a soft zone alarm.)
Advanced | Comm Menu | Vw/Edt Comm
Exit Error Event Report: Enabled
Recent Closing Event Report: Enabled
Standard Menu \ Zone/Panics
Duress (Code) Zone 101 - Disabled
Standard Menu { User Codes
Duress Code 95 - Blank
Standard Menu | Dial Prefix
Area Blank - used to enter call waiting digits/characters
Additional Notes and Cautions:
1.
The aggregate of the Entry Delay and Abort Window (Dialer
Delay) shall not be programmed to exceed one minute.
2.
Caution: A call waiting cancel on a non-call waiting line will
prevent successful connection to the central station.
3.
The panel will not allow Duress Codes to be programmed as
an existing code plus one ( + 1).
4.
Recent Closing interval is always enabled.
5.
Automatic Swinger Reset (default disabled) - If enabled,
zones shut down due to swinger bypass will automatically
reset after 48 hours with no trips on any zone. Zones can
also be manually reset.
Swinger Bypass - If enabled, the zone will shut down after
the programmed value in the Swinger Trips area.
6.
Additional keypads may be required so that Exit/Entry
annunciations can be heard within the entire protected area.
7.
System Test is initiated under the installer programming
mode under Test | Installer Test.
8.
If Cross Zoning is enabled, do not Cross Zone Exiti Entry
zone types.
9.
If more than eight (8) zones are being used, use the
Premium (ICON) keypads.
6.4 System Specifications
Alarm output: Internal Siren, 8 Ohms (nominal)
Auxiliary and Fire power: 1.2 A maximum
Control Panel Enclosure (Residential):
Dimensions: 15.0" L x 12.7" W x 3.0" D
38.0 cm L x 32.3 cm W x 7.8 cm D
Weight: 5.77 lbs. / 2.85 kg.
Environmental Range:
Temperature: 0 - 50°C
Relative Humidity: up to 95% non-condensing
Control Panel Enclosure (Commercial):
Dimensions: 18.5" L x 15.0" W x4.4" D
47.0 cm L x 38.0 cm W x 11.2 cm D
Weight: 15.89 lbs. / 7.85 kg.
16
©2003 IntelliSense
IntelliSense is a registered trademark of Honeywell International Inc. -
All other brands mentioned are the trademarks or registered trademarks of their
respective owners. - All Rights Reserved. - Specifications subject to change
without prior notice.
K9309V1 12/03 Rev A

Advertisement

Table of Contents
loading

Table of Contents