Compliance Information - BRINKS BHS3000C Installation And Programming Instructions

Table of Contents

Advertisement

BHS-3000C Installation and Programming Instructions
Correction
5
Device supervisory
problem.
A wiring
problem exists.
Verify the wire connections.
Replace any defective wires.
Replace device or panel, as
necessary.
6
Siren supervisory
failure.
A wiring
problem exists.
Verify the wire connections.
Replace any defective wires.
Replace siren or panel, as
necessary.
8
Line cut
The
telephone line has
been cut, or service
is interrupted.
Hang up ail telephones. If the
telephone service is
interrupted, instruct the
customer to call the
telephone company.
To identify whether the ninth condition exists, press the OPTIONS
+ 9 keys again. If the zone LED 1 is lit, a Host failure has
occurred.
1
Host failure.
The
control panel could
not complete a call
to the Downloader.
Verify the telephone service
is working. Verify the panel
programming. Verify wiring
connections. Replace any
defective wires. Replace
control panel, if necessary.
2
AC Failure.
The AC
power to the panel is
interrupted.
Check to ensure the panel is
plugged in. Check for broken
or loose wires. Is power out
in the rest of the house? If
not, check the circuit breaker.
If AC is present across terminal
1 and 2, then replace control
panel.
6 Compliance information
6.1 ULICUL Compliance
6.1.1 Residential Listings (US and Canada)_
When installed following the guidelines presented below, the
BHS-3000C system is compliant with these agency listings:
• UL 985 - Household Fire Warning System Units
• UL 1023 - Household Burglar Alarm System Units
• UL 1635 - Digital Alarm Communicator system Units
• UL 1637 - Home Health Care Signaling Equipment
The system also complies with the following Canadian listings:
• CAN/CUL-S545-M89 - Standard for Residential Fire Warning
System Control Units
• UL 1023 - Household Burglar Alarm System Units
6.1.2 Hardware Guidelines_
• Use only UL listed devices.
• Use recognized limited energy cables.
• Do not plug the transformer into a receptacle that is controlled
by a switch. Use an approved transformer from the list below
(according to location of installation):
Note: Part Numbers in italics = w/Ground Terminal
US
(UL Listed)
Canada
(UL/CSA Listed)
Basier
16.5V 25VA
BE116225CAA0002
BE116225AAA0024
16.5V 25VA
BE116225CAA0001
16.5V 40VA
BE156240CAA0007
UltraTech
16.5V 40 V A
IM-16V 40VA
IM-16V 40VA
16.5V 4OVA
E-HWA T16V40
E-HWA T16V40
ELK
16.5V 40VA
TRG1640
Universal
16.5VAC 40VA
UB1640W
16.5VAC 25VA
UB1625B/US2
16.5VAC 25VA
UB1625B/US3
UB1625B/CA3
Revere
16.5VAC 40VA
RT-1640
• Use one of the 12 VDC batteries listed below:
Premier 12VDC 4AH
PT1245
Power Sonic 12VDC 5AH
PS1250
Power Sonic 12VDC 7AH
PS1270
Universal Battery 12VDC 7AH
UB1270
Universal Battery 12VDC 4.5AH
UB1245
Yuasa 12VDC 4AH
NP4-12
Yuasa 12VDC7AH
NP7-12
The backup battery requirements are:
• 24 hour w/ 4 minute alarm time - Residential Fire (US &
Canada), Home Health Care.
• 4 hour w/5-15 minute alarm time - Residential Burglary (US
& Canada) Commercial Burglary and DACT.
• Use Premier or Universal PTS-15 BHSW Range 4-16 Ohm
speaker across the SIREN and Common terminals for
Residential Fire and Burglary applications. For Canadian
Residential Fire, use the Amseco MSB Series 12VDC bell.
• Fire zones must use System Sensor Model 2112ATL smoke
detector, ADEMCO 5808LST wireless smoke detector or
other UL Listed 4-wire Smoke Detector with EOL Relay.
• Use the IntelliSense 9.X 4.7 K EOL resistors for all fire zones.
• Use 4.7K Ohm end-of-line resistors on all burglary zones.
• Do not exceed the maximum combined auxiliary, fire and
keypad current (1.0A for a 25VA or 1.2A with a 40VA
transformer, including alarm outputs).
• Do not exceed the maximum current draw for the Bell output
(1 A). The primary sounding output device should be a siren
for residential systems or a bell for commercial systems.
• Install the keypads within the protected area. If mounted
outside of protected areas, keypads must be set up for
tamper protection.
• Use SIA format with Silent Knight 9800 Receiver.
Note: The Keyfob and Keyfob Receiver have not been
investigated by Underwriters Laboratories, Inc.
6.1.3 Programming Guidelines
To ensure that the BHS-3000C system is compliant with the
Listings in Section 6.1.1, program the system as follows:
• The MOS Suspend mode is not to be used in UL Certified
installations.
• Program each keypad's exit delay to be 60 seconds or less.
(Standard Menu | Set Exit Delay)
• Program each entry delay for 45 seconds or less. (Advanced
Menu | Account | Area | Zone j Vw/Edt Zone | Entry Delay
Time) Program each Entry/Exit Zone individually.
• User Codes must be at least 4 digits long (Advanced Menu j
Account | Vw/Edt Acnt | User Code Length).
• Siren Supervision must be enabled.
• Program all burglary sounding devices to operate for at least 4
minutes. (Advanced Menu | Device | Vw/Edt Device 0 ( Alarm
outputs J Burglary Cutoff) Set Burglary Cutoff Time to a
minimum of 5 minutes for Home Health Care applications.
14