Download Print this page

HP 5245L Service Manual page 9

Electronic counter
Hide thumbs Also See for 5245L:

Advertisement

Model
5245L
Section
I
,Paragraphs
1-1
to
1-10
SECTION
I
CENERAT INFORMATION
I-I.
INTRODUCTION.
L.2.
DESCRIPTION.
1-3.
The
HP
Model 5245L Electronic Counter
is
a
high-frequency general-purpose
electronic courter.
The Model
5245L measures
frequencies
from
0
to
50
Mfu,
periods
from 1
p.
sec
to
10
seconds,
period
averages
from
10
to
1001000
periods, the
ratio
of two
frequencies, andthe
multiplied ratio
of
hvofrequencies.
l-4.
The
HP
Model
5245L
provides these additional
features:
a.
Decade scaling
to
1Og
for
any frequency
to
50
MHz.
b.
Standard
output frequencies
from
0.1
Hz
to
10
MHz
in decade
steps.
c.
Four-line, binary-coded-decimal
output
to
drive
digital recorder
(HP Model
562A), digital
to
analog
converter
(HP
Model 580A/581A), remote readout,
or
data
processirg; equipment (1-2-2-4 code; L-2-4-8
code
available
(see
Section
V).
€.
Display storage
whichpermits readingto bedis-
played
while
new
count
is
made.
d.
Remote
control
by
external
contact
closure avail-
able (see Section
V).
f.
Eight-digit display using rectangular
(narrow)
digitat display
tube
s;
decimal point position
and
meas-
urement units displayed automatically.
g.
Operation with plug-in units which
extend the
basic range
and
performance of the counter.
1-5.
The Model 5245L features solid state
design,
low power consumption, small size
(5-1/4
ineh
panel
height), lightweight
(32
1b), easy
conversionforrack
mounting, and modular
plug-in circuit
boards
for
simplif ied maintenance.
I-6.
INSTRUMENT IDENTIFICATION.
t-7.
EachModel 5245Lis identified bya two-section,
eight-digit
(000-00000)
serial
number on the rear
panel.
The
five-digit
number
is
an identification
number unique
to each
instrument,
and
the
three-digit
number
is
a serial prefix number,
used
to
document
changes.
1-8.
AII
instruments with the same serial
prefix
are
the same. The
group
of
instruments
to
which this
manual
applies directly
is
identified
on
the
title
page.
For older instruments (lower serial numbers),
make
manual changes
listed
in
Section
VL
For newer in-
struments,
having
serial
numbers
higher than
those
listed
on
the
title
page, a Manual
Change
sheet
is in-
cluded,
describing the required changes. The
manual
for
an
instrument having special
electrical
modifica-
tion
will
include an insert sheetdescribing thatmodi-
fication.
If
a
change sheet
or
special information
sheet
is
missing, the information
can
be
supplied by
any
Hewlett-Packard sales and service office listed at the
back of
this
manual.
I.9.
INSTALLATION AND OPERATION,
1-10.
Installation
and operation procedures are
covered in Sections tr and
III
of the Modet 5245L Op-
erating Manual.
An explanation
of the Counterts con-
trols
and connectors and
a
self-check procedure is
included
in SectionVI of
this
manual
(see
Figures 6-1,
6-2,
and
6-3).
02349-1
1-1

Advertisement

loading