Air-O-Swiss AOS 7131 Instructions For Use Manual

Air-O-Swiss AOS 7131 Instructions For Use Manual

Air-o-swiss air cleaner user manual
Hide thumbs Also See for AOS 7131:

Advertisement

PLEASE READ AND SAVE
ALL INSTRUCTIONS!
LISEZ ET CONSERVEZ
TOUTES LES INSTRUCTIONS!
POR FAVOR LEA Y
GUARDE TODAS!
AOS 7131

Advertisement

Table of Contents
loading

Summary of Contents for Air-O-Swiss AOS 7131

  • Page 1 PLEASE READ AND SAVE ALL INSTRUCTIONS! LISEZ ET CONSERVEZ TOUTES LES INSTRUCTIONS! POR FAVOR LEA Y GUARDE TODAS! AOS 7131...
  • Page 3: Instructions D'utilisation

    Instructions for use (5 – 16) Instructions d‘utilisation (17 – 28) Instrucciones para el uso (29 – 9)
  • Page 5 Instructions for use...
  • Page 6: Important Safety Instructions

    PLEASE READ AND SAVE ALL THESE INSTRUCTIONS! Important safety instructions • Prior to using the appliance, read through the in­ structions for complete use and retain in a safe place for later reference. • WARNING – Only use the Ultrasonic indoors and within the specified technical data. Improper use can be hazardous for the health and lead to critical injury. • Connect the unit only to alternating current with voltage according to the rating label. • Children cannot recognize the hazards associated with the usage of electrical appliances. For this reason, always supervise children when they are near the humidifier (image 1). • Never use the appliance if there is any damage to the appliance or cable (2), after malfunction, after the appliance has been dropped (3) or damaged in any other way. • Repairs of electrical appliances are only to be made by qualified service engineers (4). Improper repair work can cause considerable danger to the user. • Place the humidifier on a dry, level surface (5). • Do not place the appliance directly on the floor or next to heating.
  • Page 8: General Information

    Foreword Congratulations on your choice of the Ultrasonic AIR­O­SWISS 7131! Did you know that dry room air: • Causes the membranes in your respiratory system to dry out, and also causes chapped lips and stinging eyes? • Encourages infections and illnesses of respiratory system? • Causes weariness, tiredness and poor concentration? • Stresses household pets and house plants? • Encourages the formation of dust and the electrostatic charging of textiles made of synthetic fibers, carpets and plastic flooring? • Damages furnishings made of wood and parquet? • Detunes musical instruments? General information A comfortable atmosphere indoors is reached with a re­ lative humidity level between 40 and 60%. Your humidi­ fier controls automatically the humidity level according to desired setting. If the air is too dry, the humidifier will automatically switch on. As soon as the desired humidity...
  • Page 9: Filling The Tank

    O/ I Filling the tank Always unplug the unit before removing the water tank. Do not touch the water in the base during operation! Do not operate the humidifier when the water tank is empty! When the water reaches the minimum level, the unit switches off the nebulizer function automatically. The red light comes on indicating tank is empty. • Make sure that no foreign objects are in the water tank. • Take off the water tank cap to fill the tank with water (11). Fill the tank with clean, cold water from the tap (12). Close the cap of the water tank securely, place the water tank and then the cover onto the base (13). The water is now running from the tank into the base. • Do not pour water into the mist outlet of the appliance (14). • Insert the plug into the socket and switch on the appliance using the on/off switch (15). The green light comes on. If you see the red light that displays that the water tank is empty.
  • Page 10 Water quality maintenance An Ionic Silver Stick (16) keeps the water free of harmful © bacteria. The anti­microbial action of silver is used. The Ionic Silver Stick releases silver ions in the water over a long period (approx. one year). It‘s self­regulating and maintenance­free. Look at picture 16 for the position of the ISS in the base part of the unit. Do not touch the water in the base during operation! Switch off the unit first. Contact your local retailer or check our website www.air­o­swiss. com for reorder information. Operation 131 A) On-off switch and regulation of mist output Turning the right­hand rotary switch clockwise switches the appliance on and at the same time regulates the mist...
  • Page 11 Option B: replace the whole cartridge • Remove the cover (Caution: the mist outlet is loose!). Remove the water tank from the base and unscrew the water tank cap (17). • The demineralization cartridge is attached to the inside of the tank cap. Unscrew the cartridge from the cap by turning it counter­clockwise (18). Important: do NOT dispose of the water tank cap! • Throw the whole cartridge into the waste (21). • Unpack the new cartridge (23). • Screw the cartridge on the water tank cap (25). Close tank cap well, place the tank on the lower part and insert mist outlet (26). • Soak the new cartridge for 24h before use! The resin must soak up water to reach full performance! Cut the bag open at the marked point. en en...
  • Page 12 Cleaning/Maintenance Always unplug the unit before removing the water tank. Do not touch the water in the base during operation! • Switch off the appliance and unplug it from the socket before cleaning it (27). • Clean the water tank and the base regularly. Use water only, no detergents (28). • Use decalcification agents to remove deposits from the membrane regularly (29 and 30). For best results use EZCal Custom cleaning agent for AIR­O­SWISS products. • Do not submerge base in water (31)! Attention • Make sure main body is never submerged into water (31)! • Clean the inner parts with a soft cloth. Do not use any solvents or aggressive cleaning agents to clean the appliance (32). • Only use the brush to clean the membrane. This should be done once a week. Only use the soft­bristle portion of the brush. • Change the water in the tank at least once a week if water is standing for more than a week.
  • Page 13: Technical Data

    Storing the appliance for extended periods Clean the appliance as described earlier and allow to dry thoroughly. Preferably store the appliance in its original box, in a dry place away from high temperatures. Legal notice The humidifier is UL­listed. Subject to technical change. The instructions for use are protected by copyright © PLASTON AG. Accessories Contact your local retailer or check our website www. air­o­swiss.com for reorder information. Customer Service Customer Service (USA) 1­800­336­0326 Service à la clientèle (é.­U.) 1­800­336­0326 www.air­o­swiss.com Trouble shooting Problem Possible cause Unit does not operate Power cable not plugged in No water in the tank (Empty­light red) No mist output Desired humidity level lower than actual Residues of dish soap Weak mist output Water temperature too low...
  • Page 14 General Humidifier Questions Q. Why isn’t there enough moisture in my room? A. How often do you run the unit? If the unit is only run at night, then during the day the moisture level will drop if moisture is not constantly added to the air. A. Do you leave your door open or closed when the unit is running? a. By leaving the door open, this allows moisture to leave the room and go into other areas of the house. If you would like the moisture to stay within one specific room you should consider closing the door while the unit is running. b. Wood, leather, carpet, curtains, and other types of fabric soak up a lot of moisture, thus not leaving enough moisture for the air. If the window is left open, then this allows moisture to escape the room. Another factor is a lot of times the unit is placed next to a heating device. The idea is that the air blowing into the room will quik­...
  • Page 15 is used. An indication of when the DMC needs to be changed can be white dust or reduced amount of mist output. Q. Is it ok to use distilled water with the unit? A. Yes, it is fine to use distilled water with the unit. If distilled water is used, it will prolong the life of the DMC. Q. I just replaced the contents of the cartridge and now have granules everywhere. A. First, make sure there are no granules in the middle of the cartridge. Placing granules in the middle of the DMC allows them to escape everywhere. Immedia­ tely turn off the unit, and empty the water out of the base and the water tank. Begin removing all granules from base and water tank. Use brush to clean around membrane. For refilling the DMC, wad a piece of paper or paper towel and place in the middle of the DMC. For placing granules in the cartridge, a suggestion is to use a spoon so that no granules get in the middle of the cartridge.
  • Page 17 AIR-O-SWISS is a brand name of PLASTON AG, Switzerland.

Table of Contents