SkoFlo Industries SF5000HTVB Operation And Maintenance Manual

Surface cimv, low flow, htv 5000 psi
Table of Contents

Advertisement

Quick Links

Industries
Surface CIMV, Low Flow, HTV
5000 psi
SF5000HTVB
DOC-04072 Rev A
Operations and
Maintenance Manual
Pioneering an Industry

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SF5000HTVB and is the answer not in the manual?

Questions and answers

Summary of Contents for SkoFlo Industries SF5000HTVB

  • Page 1 Industries Surface CIMV, Low Flow, HTV 5000 psi SF5000HTVB Operations and Maintenance Manual Pioneering an Industry DOC-04072 Rev A...
  • Page 2: Table Of Contents

    Valve Reassembly ............9 Table 1 – Filter Specification ............4 Handle Installation ..........10 Table 2 – SF5000HTVB Spares Kit Part Numbers ....5 Disconnecting Valve From the SF3 Actuator 11 Table 3 – SF5000HTVB Rebuild Kit Number Guide ....5 Reconnecting the SF5000HTVB to the SF3 Actuator ...................
  • Page 3: About Skoflo

    The SF5000HTVB regulates flow to counter pressure ! WARNING changes on the inlet and outlet of the unit. This is referred to as “pressure independence”.
  • Page 4: Hydraulic Ratings

    Any open hydraulic connections will be furnished with plastic blanking plugs. Install the SF5000HTVB so that the flow is in the proper direction. The IN (inlet) and OUT (outlet) connections are It is important not to store the SF5000HTVB with marked respectively.
  • Page 5: Start Up Procedures

    SkoFlo SF5000PDFMA, however, it must be capable of withstanding the process pressure. Another method of calibrating the SF5000HTVB is with a 3-way valve and a A pulsation dampener is recommended to be installed on line to a calibration beaker. Once the flow rate is set, the...
  • Page 6: General

    Surface CIMV, Low Flow, HTV SF5000HTVB 5. General Table 5 – SF5000HTVB Stem Kit Number Guide Spares kits available for typical maintenance items are listed in Table 2. See Tables 3, 4, and 5 for part number guides. Table 2 – SF5000HTVB Spares Kit Part Numbers...
  • Page 7: Disassembling The Sf5000Htvb

    Remove the spring and gate pad assembly – A brass rod can be used to aid pad assembly removal. Figure 2 – SF5000HTVB Cross-Section Remove the valve from the system. If applicable, see Section 13 for information on unpairing the valve from an SF3 Actuator.
  • Page 8: Replacing The Stem Assembly Seals

    Surface CIMV, Low Flow, HTV SF5000HTVB 7. Replacing the Stem Assembly Seals Figure 7 – Stem Assembly Seals Screw the O-ring installation tool onto the PN 31479 stem as shown in Figure 8 – (Actuated) or 31480 (Manual) Figure 5 – Piston Assembly Removal...
  • Page 9: Replacing The Gate Pad And Gate Pad Assembly Seals

    Surface CIMV, Low Flow, HTV SF5000HTVB Remove the spiral ring from the piston Apply O-ring lube to the new 2-012 O-ring pick or small screwdriver assembly – and install on the gate pad seal retainer. Remove the cup seal from the piston and Apply O-ring lube to the gate pad shaft.
  • Page 10: Valve Reassembly

    Apply a small amount of low strength Loctite to the external threads of the stem bushing. 10.8 Screw the stem bushing into the body. Figure 15 – SF5000HTVB Cross-Section Tighten hand tight. Note: the body must be held in a horizontal position during this step 11.1...
  • Page 11: Handle Installation

    Surface CIMV, Low Flow, HTV SF5000HTVB 11.6 Verify that the gate profile is visible in the 11.18 Verify that the gate profile is visible in the gate pad bore and the gate guide ring is not gate pad bore and the gate guide ring is not visible.
  • Page 12: Disconnecting Valve From The Sf3 Actuator

    Surface CIMV, Low Flow, HTV SF5000HTVB 13. Disconnecting Valve From the SF3 Actuator 14. Reconnecting the SF5000HTVB to the SF3 Actuator 14.1 Apply a thin layer of anti-seize to the valve square. 14.2 Remove the grommet from the actuator bracket.
  • Page 13: Frequently Asked Questions

    Surface CIMV, Low Flow, HTV SF5000HTVB 14.14 Tighten the nuts slightly past their previously REQUENTLY SKED UESTIONS marked position. See Figure 22 for details – 2x 9/16” wrench. Table 7 – Frequently Asked Questions ALL CIMVs ! WARNING Question Answer THE SWAGELOK FITTINGS MUST BE TIGHTENED ACCORDING TO SWAGELOK STANDARDS –...
  • Page 14: Troubleshooting

    Surface CIMV, Low Flow, HTV SF5000HTVB ROUBLESHOOTING Figure 23 – Troubleshooting Operations and Maintenance Instructions...
  • Page 15: Appendixa - A Typical Chemical Injection System

    Surface CIMV, Low Flow, HTV SF5000HTVB A – A T PPENDIX YPICAL HEMICAL NJECTION YSTEM NOTES Any number of injection points can be served by a single pump and header system. The only limitation is the flow capability of the pump.
  • Page 16: Appendixb - Sf5000Htvb Ga And Bom Drawings

    Surface CIMV, Low Flow, HTV SF5000HTVB B – SF5000HTVB GA BOM D PPENDIX RAWINGS Operations and Maintenance Instructions...
  • Page 17 Surface CIMV, Low Flow, HTV SF5000HTVB Operations and Maintenance Instructions...
  • Page 18 Surface CIMV, Low Flow, HTV SF5000HTVB Operations and Maintenance Instructions...
  • Page 19 Surface CIMV, Low Flow, HTV SF5000HTVB Operations and Maintenance Instructions...
  • Page 20 Surface CIMV, Low Flow, HTV SF5000HTVB Operations and Maintenance Instructions...
  • Page 21 SkoFlo Industries 14241 NE 200 Street Woodinville, WA 98072 USA Tel 1-425-485-7816 Fax 1-425-368-1696 www.SkoFlo.com DOC-04072 Rev. A...

Table of Contents