The SF5000HTVB regulates flow to counter pressure ! WARNING changes on the inlet and outlet of the unit. This is referred to as “pressure independence”.
Any open hydraulic connections will be furnished with plastic blanking plugs. Install the SF5000HTVB so that the flow is in the proper direction. The IN (inlet) and OUT (outlet) connections are It is important not to store the SF5000HTVB with marked respectively.
SkoFlo SF5000PDFMA, however, it must be capable of withstanding the process pressure. Another method of calibrating the SF5000HTVB is with a 3-way valve and a A pulsation dampener is recommended to be installed on line to a calibration beaker. Once the flow rate is set, the...
Surface CIMV, Low Flow, HTV SF5000HTVB 5. General Table 5 – SF5000HTVB Stem Kit Number Guide Spares kits available for typical maintenance items are listed in Table 2. See Tables 3, 4, and 5 for part number guides. Table 2 – SF5000HTVB Spares Kit Part Numbers...
Remove the spring and gate pad assembly – A brass rod can be used to aid pad assembly removal. Figure 2 – SF5000HTVB Cross-Section Remove the valve from the system. If applicable, see Section 13 for information on unpairing the valve from an SF3 Actuator.
Surface CIMV, Low Flow, HTV SF5000HTVB Remove the spiral ring from the piston Apply O-ring lube to the new 2-012 O-ring pick or small screwdriver assembly – and install on the gate pad seal retainer. Remove the cup seal from the piston and Apply O-ring lube to the gate pad shaft.
Apply a small amount of low strength Loctite to the external threads of the stem bushing. 10.8 Screw the stem bushing into the body. Figure 15 – SF5000HTVB Cross-Section Tighten hand tight. Note: the body must be held in a horizontal position during this step 11.1...
Surface CIMV, Low Flow, HTV SF5000HTVB 11.6 Verify that the gate profile is visible in the 11.18 Verify that the gate profile is visible in the gate pad bore and the gate guide ring is not gate pad bore and the gate guide ring is not visible.
Surface CIMV, Low Flow, HTV SF5000HTVB 13. Disconnecting Valve From the SF3 Actuator 14. Reconnecting the SF5000HTVB to the SF3 Actuator 14.1 Apply a thin layer of anti-seize to the valve square. 14.2 Remove the grommet from the actuator bracket.
Surface CIMV, Low Flow, HTV SF5000HTVB 14.14 Tighten the nuts slightly past their previously REQUENTLY SKED UESTIONS marked position. See Figure 22 for details – 2x 9/16” wrench. Table 7 – Frequently Asked Questions ALL CIMVs ! WARNING Question Answer THE SWAGELOK FITTINGS MUST BE TIGHTENED ACCORDING TO SWAGELOK STANDARDS –...
Surface CIMV, Low Flow, HTV SF5000HTVB A – A T PPENDIX YPICAL HEMICAL NJECTION YSTEM NOTES Any number of injection points can be served by a single pump and header system. The only limitation is the flow capability of the pump.
Need help?
Do you have a question about the SF5000HTVB and is the answer not in the manual?
Questions and answers