5. ASSEMBLY
5.1.
Undo clasps.
5.2.
Lift off the motor head assembly.
5.3.
Remove contents from inside the drum.
5.4.
Turn the drum upside down and insert the castors ensuring they are pushed all the way in.
5.5.
Insert the rear rubber wheels and attach to the rear axle if not already assembled.
5.6.
Insert the cloth filter and bag.
5.7.
For wet vacuum cleaning ensure that the cloth filter is removed.
5.8.
Replace the motor head onto the drum.
5.9.
Align up the motor head with the clasps and snap into place,by applying pressure at the mid point of the clasps.
5.10.
Insert the large end of the hose into the front inlet of the drum and lock in place by turning fully clockwise.
5.11.
Choose the desired nozzle and push it onto the suction tube.
6. DRY VACUUM CLEANING
WARNING! Ensure you read, understand and apply Section 1 'Safety Instructions'.
WARNING! DO NOT vacuum hazardous substances.
6.1.
Ensure the machine is unplugged from the power supply.
6.2.
Ensure cloth filter and cloth bag are fitted.
6.3.
Reposition the head onto the drum, and clip in place.
6.4.
Insert the larger end of the flexible hose into the front inlet on the drum and lock in place. Push the required attachment/suction tube onto
the free end of the hose.
6.5.
Plug in the power supply.
6.6.
Switch to the 'On' (position 'I') from one or both sides.
6.7.
When you have completed vacuuming, press the switch/switches to the 'Off' (position '0').
7. WET VACUUM CLEANING
WARNING! Ensure you read, understand and apply Section 1 'Safety Instructions'. Reminder: Remove plug from power supply before
opening unit.
DO NOT vacuum solvents, explosives, inflammable and/or hazardous liquids such as petrol, oil, spirits, paint, thinners, acids etc.
8
DO NOT use cloth filter or cloth bags when wet vacuuming.
8
7.1.
Ensure the machine is unplugged from the power supply. Make sure the tank is clean and free from dust and dirt.
7.2.
Remove the cloth filter and replace motor head assembly onto the drum.
7.3.
Fit the desired nozzle (to the same flexible hose used in dry cleaning).
7.4.
Ensure the switches are in the 'Off' (position '0') before plugging into the power supply (both switches).
7.5.
Press the switch or switches to the 'On' (position 'I').
NOTE:To vacuum large quantities of liquid, from a sink or tank etc, DO NOT immerse the nozzle completely in the liquid, leave a gap at
the top of the nozzle opening to allow an air inflow. The machine is fitted with a float valve which stops the suction action when the tank
has reached its maximum capacity. The user will notice an increase in motor speed. When this happens, turn off the machine,
disconnect from power supply, remove the motor head assembly from the drum and empty the liquid into a suitable receptacle or
drain. To continue vacuuming, refit the head and proceed. After wet vacuuming, turn the machine off and unplug from power
supply. Empty the drum and clean and dry the inside and outside before storage.
WARNING! Not designed for liquid storage. Always empty liquids after use and before storing.
8. MAINTENANCE
8.1.
GENERAL MAINTENANCE.
Warning! The plug must be removed from the socket before cleaning or maintaining the appliance.
8.1.1.
Disconnect the hose from the drum.
8.1.2.
Undo the clasps and remove motor head assembly from the drum.
8.1.3.
Clear out any dirt or debris from the drum and hose.
8.1.4.
Check that the suction tube operates smoothly and check the power cable to make sure it has not received any damage.
9. TROUBLESHOOTING
Problem
Cleaner will not operate.
Dust comes from the
motor cover.
Reduced efficiency and
increased motor speed/
vibration.
© Jack Sealey Limited
Cause
1. No power supply.
2. Faulty power cable, switch or motor.
3. Drum full of liquid.
1. Cloth filter missing or
damaged.
1. Dust drum full.
2. Filter clogged.
3. Nozzle, hose or drum inlet blocked.
Original Language Version
Solution
1. Check supply.
2. Check and repair or replace faulty item.
3. Empty drum.
1. Fit or replace cloth filter.
1. Empty drum.
2. Clean or replace cloth filter.
3. Check nozzle, hose and drum inlet for blockage/
clear blockage.