Air-O-Swiss AOS 2055 Instructions For Use Manual

Air-O-Swiss AOS 2055 Instructions For Use Manual

Air-o-swiss air cleaner user manual
Hide thumbs Also See for AOS 2055:

Advertisement

PLEASE READ AND SAVE
ALL INSTRUCTIONS!
LISEZ ET CONSERVEZ
TOUTES LES INSTRUCTIONS!
POR FAVOR LEA Y
GUARDE TODAS!
AOS 2055
AOS 2055D

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AOS 2055 and is the answer not in the manual?

Questions and answers

Summary of Contents for Air-O-Swiss AOS 2055

  • Page 1 PLEASE READ AND SAVE ALL INSTRUCTIONS! LISEZ ET CONSERVEZ TOUTES LES INSTRUCTIONS! POR FAVOR LEA Y GUARDE TODAS! AOS 2055 AOS 2055D...
  • Page 3 Instructions for use (5 – 17) Instructions d‘utilisation (18 – 0) Instrucciones para el uso (1 – 4)
  • Page 5 Instructions for use...
  • Page 6: Important Safety Instructions

    PLEASE READ AND SAVE ALL THESE INSTRUCTIONS! Important safety instructions • Prior to using the appliance, read through the in­ structions for complete use and retain in a safe place for later reference. • WARNING – Only use the appliance indoors and within the specified technical data. Improper use can be hazardous for the health and lead to critical injury. • Connect the unit only to alternating current with voltage according to the rating label. • Children cannot recognize the hazards associated with the usage of electrical appliances. For this reason, always supervise children when they are near the humidifier (image 1). • Never use the appliance if there is any damage to the appliance or cable (2), after malfunction, after the appliance has been dropped (3) or damaged in any other way. • Repairs of electrical appliances are only to be made by qualified service engineers (4). Improper repair work can cause considerable danger to the user. • Place the humidifier on a dry, level surface (5). • Do not place the appliance next to heating. • Place appliance where it is not easily knocked over (6). • Always unplug when not in use.
  • Page 8: How It Works

    How it works Your appliance • washes and humidifies the air without using filter mats • works quietly in two operation modes • is manufactured from high­quality, long­life components. • has a large cleansing capacity through pre­ionization. The individual dust particles are ionized (charged) and stick to the humidifier discs. Special humidifying discs rotate in a water bath inside the unit; this cleanses the air passing over them of impurities in a natural way – in the same way that air is washed by the rain in nature. The air humidification takes place according to the self­ regulating principle of cold evaporation. The appliance therefore generates ideal air humidity, without the need for additional control units. A specially tuned anti­bacterial protection system (Ionic Sil­ ver Stick ® ) prevents the formation of germs in the water of the base unit. No chemical additives are therefore required to keep the water clean.
  • Page 9: Description Of The Appliance

    Description of the appliance Air inlet Cover Control panel Air outlet 1 disc pack with 16 humidifying discs Rotary lock Fragrance container and rotary lock opener for humidifying discs Water base Water tank Water tank cap Ionic Silver Stick ® (ISS)
  • Page 10: Putting Into Operation

    Putting into operation The best location for your appliance is: • On the floor, or on a level, dry surface in the room. • Pay proper attention to easy accessibility and sufficient space for servicing and cleaning the unit. • For increased evaporation performance in large rooms, place the appliance near a radiator (warning: a tempe­ rature of 122 °F / 50 °C must not be exceeded). • Read the section “Filling the tank” on how to fill the water tank (20 – 24). • Place the water tank on the lower part (24). • Connect the mains cable to the mains and switch the appliance on using the On/Off switch. • The unit will reach full capacity about 10 – 15 minutes after you switch it on. • Ensure that the mains cable is not trapped (9). Do not switch on the unit if the mains cable is defective (2). Filling the tank Always unplug the unit before removing the wa­ ter tank. Do not operate the appliance when the water tank is empty! Only fill the water tank with fresh, cold tap water. Use other solution at your own risk. We do no accept any liability for possible reductions in performance or damage. Do not put the water tank under pressure, e.g. by filling with carbonated mineral water. Do not add any essential oils or fragrances to the water; the plastic material might then become discoloured and damaged. Close bayonet cap (23) fully to prevent water from leaking out of the tank.
  • Page 11 Water quality maintenance An Ionic Silver Stick (26) keeps the water free of harmful © bacteria. The anti­microbial action of silver is used. The Ionic Silver Stick releases silver ions in the water over a long period (approx. one year). It‘s self­regulating and maintenance­free. Look at picture 26 for the position of the ISS in the base part of the unit. Switch off the unit first.
  • Page 12: Cleaning & Maintenance

    automatically changes to show the current value (CUR­ RENT) (E). Upon reaching the desired relative humidity, the unit automatically switches off (display shows DESIRED and CURRENT) (E). If the desired relative humidity falls, the appliance automatically switches on again. Quick display of current relative humidity When the unit is switched off (mains cable is connected, rotary switch to OFF setting), the current relative humidity can be shown in the display by briefly pressing one of the B buttons. This display automatically disappears after a few seconds. C) Change Ionic Silver Stick ® The letter C in the display indicates that the Ionic Silver Stick (ISS) must be changed. The symbol remains visible ®...
  • Page 14 Cleaning the water tank and base (every 2 weeks) • Lift the water tank out of the unit, open the water tank cap and clean the tank (35 – 37). • Lift the upper part of the unit off the base and remove the Ionic Silver Stick (38). ® • Fill the base with water, for best results use EZCal cu­ stom cleaning agent for AIR­O­SWISS products; Rotate the disk assembly a few times by hand (39). • Empty the water base (40), remove the disc assembly (41) and rinse (42). • Remove deposits from the base using a plastic or wooden brush and a diluted, commercial washing­up detergent (43). Cleaning the humidifying discs (every 4 weeks) A thin film of lime scale on the discs actually increases the humidity output! To clean, unscrew the individual humi­...
  • Page 16: Troubleshooting

    Storing the appliance for extended periods Clean the appliance as described earlier and allow to dry thoroughly. Preferably store the appliance in its original box, in a dry place away from high temperatures. Legal notice The humidifier is UL­listed. Subject to technical change. The instructions for use are protected by copyright © PLASTON AG. Accessories Contact your local retailer or check our website www. air­o­swiss.com for reorder information. Customer Service Customer Service (USA) 1­800­336­0326 Service à la clientèle (é.­U.) 1­800­336­0326 www.air­o­swiss.com Trouble shooting Problem Possible cause Appliance does not work Power plug not inserted No water in the water tank Brushing noise Disc assembly is not correctly inserted in the water base.
  • Page 17 Q. Why do I need a humidifier when I can just open my window? A. The moisture level within the outside air is not high enough to humidify a room. Q. Where should I place my humidifier? A. The unit should be free­standing and not close to a wall, window, door, or thermal bridge so that air may circulate around the unit. 2055 FAQ’s Q. I fill the water tank, and when I place it back on the unit all of the water goes into the base.
  • Page 18 AIR­O­SWISS is a brand name of PLASTON AG, Switzerland.

This manual is also suitable for:

Aos 2055d

Table of Contents

Save PDF