4 Unit installation
3 Remove the clips that lock the valves in place.
a
b
a
a
Pipes for central water loop circuit
b
Pipes for space heating/cooling circuit
4 Uncouple the piping.
5 Remove the lower hydro module cover.
T25
6 Unlink the connectors that run from the hydro module to the
main switch box or other locations. Route the wires through the
grommets of the upper hydro module cover.
Installation manual
8
b
a
b
X803YA
X22Y
7 Remove the upper hydro module cover. You can lift up the
uncoupled piping to access the screws more easily, and to take
off the cover itself.
T25
8 Remove the screw that fixes the hydro module to the bottom
plate.
9 Lift the uncoupled piping and use the handle on the front of the
module to carefully slide the module out of the unit. Make sure
the module remains level and does not tilt forward.
X1YA
X11YB
T25
EWSAH/X06UD