@ DOLBY B/C SELECTOR SWITCH
(DOLBY NR B/C)
This deck is equipped both type B and type C Dolby noise reduction
systems. After the DOLBY NR ON/OFF switch is pressed, select
type B or C using this switch. The Dolby indicator corresponding to
the switch position lights.
| & OUTPUT LEVEL VOLUME CONTROLS
(OUTPUT LEVEL)
These controls are for adjusting the deck's output level. When the
controls are turned clockwise, output level is increased. (Refer to
page 13.)
PHONES
...
Adjusts output level at headphones jack.
LINE OUT ... Adjusts output level at LINE OUTPUT (PLAY) ter-
minals on the rear panel.
NOTE:
©
The movement of the level meters is not affected by rotation of
the output level volume controls.
e
/f the output level control is set at the minimum "0" position,
no sound will be heard, even if the amplifier's volume control is
rotated.
e
/f the PHONES volume control is set at the minimum "0" posi-
tion, no sound will be heard from headphones.
€ MONITOR INDICATOR (MONITOR)
This
indicator
shows
the
monitoring
mode
selected
by the
automatic monitoring function.
@ TAPE CAPACITY INDICATOR
This indicator shows the type of tape selected with the TAPE
CAPACITY switch.
© TAPE INDICATORS
(NORM/CrO,/METAL)
This mechanism uses the sensor holes on the cassette to detect the
type of tape being used. It then automatically adjusts the proper
recording bias and equalization for the tape. The type of tape is then
shown on the tape indicator. Refer to page 19 for the different types
of cassette tapes and their hole positions.
NORM: _ This indicator lights when normal tapes are used.
CcrO,:
This indicator lights when CrO, tapes are used.
METAL:
This indicator lights when metal tapes are used.
NOTE:
When using metal tapes without sensor holes, the tape selector
will be set on the CrO, position. In this case, optimum recording
and erasure may not be possible. We thus recommend that you
use metal tapes with sensor holes. Pre-recorded metal tapes can
be played as is on this unit.
BIAS, LEVEL, EQ ADJUSTMENT
IN-
DICATORS
The AUTO BLE performs adjustments in the order bias =» level =
equalizer.
The
BIAS,
LEVEL,
and
EQ indicators light in order
together with the adjustment process. When the equalizer adjust-
ment is completed, the indicators go out.
@ DOLBY INDICATORS (DOLBY NR)
These light when the DOLBY NR switch is set to ON .
[B]: This lights when the B type Dolby noise reduction system is
operating.
[C]: This lights when the C type Dolby noise reduction system is
operating.
@ MULTIPLEX INDICATOR (MPxX)
This indicator lights when the Multiplex filter (MPX FILTER) switch
is pressed ON.
@® BIAS INDICATORS
In accordance with the setting of the bias switches, these indicators
flash during AUTO BLE adjustment, and light steadily when adjust-
ment is completed. (Refer to page 12.) -
@
HEAD CLEANING ACCESS
PORT (Refer
to page 17)
About Transparent Tape Cassettes
This unit is equipped with an automatic loading device which optically
detects the presence of a tape cassette in the cassette holder, thus
causing the cassette door to automatically close.
©
Some tape cassettes are made from a transparent plastic material.
The unit's auto loading device may not operate properly when
these transparent tape cassettes are used.
e
In this event, press the cassette door slightly with your finger, or
use one of the direct operating switches (recording switch or
playback switch) to close the cassette door.