The content includes of electric connections and operating steps
System user manual
RDV8840G-MOD5
202-203, B-Block,Technology Building, 1057 Nanhai Avenue,Nanshan District,, SHENZHEN, CHINA 1
Web:www.rd-acs.com | TEL/FAX:0755-26066687/26982287
User manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RDV8840G-MOD5 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for RuiDa RDV8840G-MOD5

  • Page 1 Read this manual before operation ➢ The content includes of electric connections and operating steps ➢ System user manual RDV8840G-MOD5 User manual Shenzhen Ruida Technology Co., Ltd Address: 202-203,B-Block,Technology Building, 1057 Nanhai Avenue,Nanshan District,, SHENZHEN, CHINA Tel: 0755--26066687 Fax: 0755--26982287 E-mail: sales@rd-acs.com...
  • Page 2 Ruida Technologies does not assume any direct or indirect liability or loss as follows: ➢ The user is using this manual or this product incorrectly ➢...
  • Page 3 CERTIFICATION STATEMENT CE Certification statement This product has passed the European Union CE (CONFORMITE EUROPEENNE) safety certification, has passed the corresponding conformity assessment procedures and the manufacturer's declaration of conformity, and complies with the relevant EU directives. ROHS Certification statement This product has passed the "Restriction of Hazardous Substances"...
  • Page 4 SAFETY INFORMATION Please make sure that the operation is correct and the method is safe when using the system. Some signs or words will be used to remind you of dangerous matters and some important information. Danger: It indicates a serious danger. In the process of using, if improper operation or wrong usage method may cause serious injury or even death to the personnel, please do not use it easily until the operation method is correct and the usage method is correct.
  • Page 5 After unpacking the goods, please check if the parts are complete. If you find that the parts are missing or the parts are damaged, please contact Ruida immediately. The RDV8840G-MOD5 control system packing list is shown in the following table: (As the product is constantly updated, the accessories that may be received are difference).
  • Page 6: Table Of Contents

    Contents Chapter 1 Overview ........................... 81 1.1 I ..........................92 NTRODUCTION 1.2 C ....................103 ONTROLLER ODEL ESCRIPTION Chapter 2 Install size ..........................114 2.1 M ......................12 OTHERBOARD MOUNT SIZE 2.2 T ...................... 147 OUCH SCREEN MOUNTED SIZE Chapter 3 Physical diagrams and interfaces ................... 169 3.1 H ....................
  • Page 7 Chapter 8 RDCloud Application Description ..................5849 8.1 RDC INTRODUCTION ..................... 5950 LOUD 8.2 P ....................5951 EATURE NTRODUCTION 8.2.1 Sign in to ..........................5951 8.2.2 Register ..........................6152 8.2.3 Reset password ........................6253 8.2.4 User Center ........................... 6354 8.2.5 Device Management ......................6455 8.2.6 Use status ..........................
  • Page 8: Chapter 1 Overview

    Chapter 1 Overview The main contents of this section: Introduction Controller model description Web:www.rd-acs.com | TEL/FAX:0755-26066687/26982287 202-203, B-Block,Technology Building, 1057 Nanhai Avenue,Nanshan District,, SHENZHEN, CHINA 8...
  • Page 9: Introduction

    1.1 Introduction RDV8840G system is a new generation laser control system developed by Ruida Technology, which has better hardware stability, abundant motion control design, and better resistance to high voltage and static interference. For the local area network control machine one-to-many, many-to-one equipment environment development of a new...
  • Page 10: Controller Model Description

    1.2 Controller model description RDV8840G-MOD5: RDV: Ruida Technology Vision Series -- 8840: Product model -- G: Standard products MOD5: MOD7: 5 inches resistance Touch screen. 7 inches resistance Touch screen. TC5: 5 inches Capacitive Touch screen. TC7: 7 inches capacitive touch screen Web:www.rd-acs.com | TEL/FAX:0755-26066687/26982287...
  • Page 11 Chapter 2 Installation Dimensions The main contents of this section: Mainboard mounting size Panel mounting size Web:www.rd-acs.com | TEL/FAX:0755-26066687/26982287 202-203, B-Block,Technology Building, 1057 Nanhai Avenue,Nanshan District,, SHENZHEN, CHINA 11...
  • Page 12 2.1 Mainboard mounting size All dimensions are in mm units, accurate to 0.1mm (Four positioning holes symmetrical). Figure 2.1.1 The top Figure 2.1.2 Left side Web:www.rd-acs.com | TEL/FAX:0755-26066687/26982287 202-203, B-Block,Technology Building, 1057 Nanhai Avenue,Nanshan District,, SHENZHEN, CHINA 12...
  • Page 13 Figure 2.1.3 Right side 2.1.4 The Back side Web:www.rd-acs.com | TEL/FAX:0755-26066687/26982287 202-203, B-Block,Technology Building, 1057 Nanhai Avenue,Nanshan District,, SHENZHEN, CHINA 13...
  • Page 14 2.2 Touch screen Mounting size All dimensions are in mm, precise to 0.1mm Figure 2.2.1 Front view Web:www.rd-acs.com | TEL/FAX:0755-26066687/26982287 202-203, B-Block,Technology Building, 1057 Nanhai Avenue,Nanshan District,, SHENZHEN, CHINA 14...
  • Page 15 Figure 2.2.2 Back view Web:www.rd-acs.com | TEL/FAX:0755-26066687/26982287 202-203, B-Block,Technology Building, 1057 Nanhai Avenue,Nanshan District,, SHENZHEN, CHINA 15...
  • Page 16 Chapter 3 Diagram and interface The main contents of this section: System wiring diagram Hardware interface description Motor wiring instructions Laser wiring instructions Web:www.rd-acs.com | TEL/FAX:0755-26066687/26982287 202-203, B-Block,Technology Building, 1057 Nanhai Avenue,Nanshan District,, SHENZHEN, CHINA 16...
  • Page 17: Ardware Interface Diagram

    3.1 Hardware interface diagram Figure 3.1 System wiring diagram 3.2 Main power interface CN4 Signal Definition +24V 24V switch power supply positive (input) 24V GND PGND PGND This control system uses a single 24V power supply, in order to leave a certain amount of margin, it is recommended to choose more than 24V / 2A power supply.
  • Page 18: Limit Switch Interface Cn1

    3.3 Limit switch interface CN1 Signal Definition Description 24V power signal Power signal XLmt- X-axis negative limit Low voltage trigger Ylmt- Y-axis Negative limit Low voltage trigger ZLmt- Z-axis negative limit Low voltage trigger Ulmt- U-axis negative limit Low voltage trigger 1.The switch must select the NPN and the limit polarity can be optional.
  • Page 19 the second foot switch is less than 100 milliseconds from the first, the second movement is considered invalid by the mainboard. input to protect the signal input, and if the Specific machine needs protection in a specific state (e.g. cover protection), protect signal from this pin input. The pin can be enabled and suppressed, when the IN-02 Cover protection...
  • Page 20 Specific output, when enable fan control, it is the fan output control signal, otherwise it is the first pen control signal. When connecting the fan and fan control enable, the fan OUT1 Fan interface switch can be set in each layer, if connect the external relay, the relay coil will be turned on when the fan is turned on, and the relay coil will be...
  • Page 21: Four-Axis Drive Interface Cn5-Cn8

    3.6 Four-axis drive interface CN5-CN8 Signal Definition Description STEP Pulse signal Direction signal Power signal The four motion axis interfaces definition are same. 3.7 Laser control signal interface CN9 Signal Definition Description LP-DO Laser power control PWM output, with LP-AO two choices LP-EN Laser enables IO control...
  • Page 22: Ethernet Interface

    3.9 Ethernet interface Ethernet is an Ethernet interface and is not available. 3.10 USB interface CN13-CN14 is a general USB interface Web:www.rd-acs.com | TEL/FAX:0755-26066687/26982287 202-203, B-Block,Technology Building, 1057 Nanhai Avenue,Nanshan District,, SHENZHEN, CHINA 22...
  • Page 23: Chapter 4 Hmi Features Introduction

    Chapter 4 HMI Introduction The main contents of this section: HMI function Introduction HMI operation Introduction Parameters Description Web:www.rd-acs.com | TEL/FAX:0755-26066687/26982287 202-203, B-Block,Technology Building, 1057 Nanhai Avenue,Nanshan District,, SHENZHEN, CHINA 23...
  • Page 24: Introduction

    4.1 Introduction RDPAD8840G-MOD5-General -5 inches touch screen panel ("Panel") is a 5 inches touch screen based on the human-machine interface, with friendly UI. Support location and processing status display in real-time, users can clearly understand the current processing situation. Support modifies the file management, user parameters and factory parameters modification, support multi-language.
  • Page 25: Introduction To The Main Interface Features

    ⚫ 16.7Mhue ⚫ MODBUS protocol communication ⚫ buzzer 4.2 Introduction to the main interface features serial Keystrokes function number System Hardware Reset Start work or pause/restart work Stop machining or motor shaft movement Memory file and USB stick file management User parameters, factory parameters, language settings, Point out light Set the anchor point...
  • Page 26 Used to move the X-axis Used to move the X-axis Used to move the Y axis Used to move the Y axis Used to move the Z-axis Used to move the U-axis 4.3 The main interface functions The main interface is displayed when the system power reset is complete. Here's the picture: The current file current file...
  • Page 27: File

    Figure 4.2 Current file name display: Displays the file name of the current processed file. Working status area: Used to display the current working status of the system, respectively, idle, pause, complete, run. The time of processing is shown on the right. Process progress bar: Show the current processing progress, the bottom left of the progress bar shows the percentage of processing progress.
  • Page 28: Menu

    Press the File button on the main interface to enter the file management interface fig 4.4.1 The current page file number, along with the file number and file name, is displayed in this interface, clicking on the icon to turn the page, clicking on the file to select, and press ‘OK’ ,The maximum number of files is 100.
  • Page 29 Figure 4.5 4.5.1 WIFI Press ‘WIFI’, the following dialog box pops up Web:www.rd-acs.com | TEL/FAX:0755-26066687/26982287 202-203, B-Block,Technology Building, 1057 Nanhai Avenue,Nanshan District,, SHENZHEN, CHINA 29...
  • Page 30 Figure 4.5.1 When entering the interface, the card's current IP address will be read, user can modify the host IP address, if the AP mode is off, the modification is successful, if the AP mode is on, it is not allowed to modify. 4.5.2 Language settings Press the ‘Language’...
  • Page 31 Figure 4.5.2 Enter the Language interface, and the gray box represents the language currently in using. Select the language, press ‘OK’ to confirm. 4.5.3 Backup Parameter Pressing the ‘Backup Prm’, the following dialog box pops up: Web:www.rd-acs.com | TEL/FAX:0755-26066687/26982287 202-203, B-Block,Technology Building, 1057 Nanhai Avenue,Nanshan District,, SHENZHEN, CHINA 31...
  • Page 32 Figure 4.5.3 Press ‘backup prm’ to backup the manufacturer parameters and user parameters in the board. 4.5.4 Restore parameters Press the "Restore prm", and the following dialog box pops up: Web:www.rd-acs.com | TEL/FAX:0755-26066687/26982287 202-203, B-Block,Technology Building, 1057 Nanhai Avenue,Nanshan District,, SHENZHEN, CHINA 32...
  • Page 33 Figure 4.5.4 Click to confirm that the factory parameters and user parameters in the memory chip of the control card are backed up for restoration. 4.5.5 System information Pressing the ‘System Info’ , the following dialog box pops up: Web:www.rd-acs.com | TEL/FAX:0755-26066687/26982287 202-203, B-Block,Technology Building, 1057 Nanhai Avenue,Nanshan District,, SHENZHEN, CHINA 33...
  • Page 34 Figure 4.5.5 Here will display the version number of the control card. 4.5.6Jog setting Press ‘Jog setting’ , the following dialog box pops up: Web:www.rd-acs.com | TEL/FAX:0755-26066687/26982287 202-203, B-Block,Technology Building, 1057 Nanhai Avenue,Nanshan District,, SHENZHEN, CHINA 34...
  • Page 35 Figure 4.5.6 Definition Description When the Jog mode is Continuous, the step distance does not work, when press the arrow button, the axis moves, when release, the axis Jog mode stops moving. When the mode is in ‘step’, the corresponding motion axis can move one of ‘step len’...
  • Page 36 4.5.7 Laser setting Press ‘Laser setting’, the following dialog box pops up: Figure 4.5.7 Definition Description When the laser mode is in ‘CW’, the laser time parameter does not work, at this time press the "pulse”, the laser on in continuation, until Laser mode release the "pulse".When the laser mode is in "pulse", Then press ‘Pulse’, the laser on automatically until the laser time was set.
  • Page 37 4.5.8 Diagnose Press ‘Diagnose’, the following dialog box pops up: Figure 4.5.7 From the "diagnosis" interface, display the hardware IO port information of the system, enter the interface to read the system hardware information, wherein, X-/Y-/Z-/U- for each axis limit signal input, the output 2/3/4/5 corresponding to the mainboard on the Out2/ Out3/ Out4/ Out5.
  • Page 38 4.6 Keyboard Lock Figure 4.6.1 When press ‘Key lock’, input the lock password, press ‘ok’, there will be the locked main interface. When you enter the locked main interface, parameters such as: "Current process file," "Process progress," "Processing time” can display, user should unlock then can operation. If the password is wrong, back to the locked main interface. Web:www.rd-acs.com | TEL/FAX:0755-26066687/26982287 202-203, B-Block,Technology Building, 1057 Nanhai Avenue,Nanshan District,, SHENZHEN, CHINA 38...
  • Page 39 Chapter 5 System debugging The main contents of this section: XY axis motion testing instructions Laser testing instructions Processing testing Web:www.rd-acs.com | TEL/FAX:0755-26066687/26982287 202-203, B-Block,Technology Building, 1057 Nanhai Avenue,Nanshan District,, SHENZHEN, CHINA 39...
  • Page 40 5.1 X, Y-axis debugging Be careful when user the first time to running the system, here is the steps: Before connecting the motor driver, set the user parameters, vendor parameters of the mainboard from software correctly, especially the work speed, motor step length, offset etc. to keep safety. Check the logic voltage of the limit switch from touch screen ‘diagnostic’...
  • Page 41 manufacturer parameters in the software. If all of the above procedures are correct, next tests can be performed. 5.3 Cutting testing Before cutting test, make sure that the wiring is correct and that the controller parameters are set correctly, that the X, Y-axis motion and laser testing is normal and the system have been reset successfully.
  • Page 42 Set the layer parameters correctly Scale On the right side of the software interface, press the ‘go scale ‘button and the laser head moves along the maximum rectangular boundary of the machined graphic. This feature allows you to understand the actual processing, and if the panel prompts the border to cross the line, it means that the cutting head movement will exceed the rectangle range, so stop to running ensure the safety.
  • Page 43 Web:www.rd-acs.com | TEL/FAX:0755-26066687/26982287 202-203, B-Block,Technology Building, 1057 Nanhai Avenue,Nanshan District,, SHENZHEN, CHINA 43...
  • Page 44 Chapter 6 Alarm Information Description The main contents of this section: Alarm information description Alarm solutions Web:www.rd-acs.com | TEL/FAX:0755-26066687/26982287 202-203, B-Block,Technology Building, 1057 Nanhai Avenue,Nanshan District,, SHENZHEN, CHINA 44...
  • Page 45 6.1 Alarm information description An alarm may be raised during the operation and the corresponding protective action may be generated to protect the machine. Alarm information includes limit trigger, cover protection, high temperature alarm, smoke alarm, etc. When an error occurs, the error is prompted on the touch screen. If an error occurs, please deal with the error based on the error prompt and then run the system.
  • Page 46 ⚫ The vendor parameters are not set correctly and the XY axis breadth does not match the actual frame of the machine. Set the XY face correctly. 6.5 Mainboard communication failed When communication failures during using, please check: ⚫ The connector between the touch screen and the mainboard is not connected correctly. ⚫...
  • Page 47 Chapter 7 Device Connections The main contents of this section: PC and device connection Connect the device through the router Web:www.rd-acs.com | TEL/FAX:0755-26066687/26982287 202-203, B-Block,Technology Building, 1057 Nanhai Avenue,Nanshan District,, SHENZHEN, CHINA 47...
  • Page 48 7.1 PC and device connection The PC search for wifi from the device, to connect the corresponding device directly. Here requires the PC has the wifi function. 7.1.1 The connection step The specific connection steps are as follows. The device is powered on. Double-click RDWorksV8Lite to start the software as shown below.
  • Page 49 Once the connection is successful, click the on the V8lite software and the following display Device setting box will pop up. Double-click ‘ (default connection IP is 192.168.20.1 when single connecting). Device’ Web:www.rd-acs.com | TEL/FAX:0755-26066687/26982287 202-203, B-Block,Technology Building, 1057 Nanhai Avenue,Nanshan District,, SHENZHEN, CHINA 49...
  • Page 50 Click to pop up the " box to indicate that the software is connected to the device (if "Test" Port Test Success" ,user should be check if the computer and device WIFI is connected successfully and " Port test failure" if IP is entered incorrectly).
  • Page 51 The test device ID is you can see on the page that the device status is connected. "88400GT00128MMJX", When a device is connected to the Internet, when we have the latest version released, we can right-click on the in the lower right corner of the computer and click on online"...
  • Page 52 7.2 Connect the device through the router The steps for connecting the mainboard through the router are as follows: The device is powered on. Double-click RDWorksV8Lite to start the software as shown below. The computer connects the mainboard (each controller has different wifi name, which can be viewed at a label on the mainboard, and the desktop computer needs to connect to the W IFI module to connect) Web:www.rd-acs.com | TEL/FAX:0755-26066687/26982287 202-203, B-Block,Technology Building, 1057 Nanhai Avenue,Nanshan District,, SHENZHEN, CHINA 52...
  • Page 53 After a successful connection, access "192.168.20.1:8080"through browser: Enter the account number and password of outer, and then click Connect Now to connect the device to the router: (Note: If the account number or password entry error, the software cannot communicate with the device.
  • Page 54 At this point, check the computer WIFI, and when the connected "device010"connection disappears, the device is connected to the router. Make the computer connect into WIFI which from the device, as shown below. Once the device enters the router, it can view the :( assigned to the mainboard IP by the router through the touch screen.
  • Page 55 Open the V8Lite software, click "Device setting" and click the "Add" button in the pop-up interface. In the pop-up "Port setting" interface, the IP address is modified to the IP displayed by the touch screen: e.g. 192.168.3.103, as shown below. Web:www.rd-acs.com | TEL/FAX:0755-26066687/26982287 202-203, B-Block,Technology Building, 1057 Nanhai Avenue,Nanshan District,, SHENZHEN, CHINA 55...
  • Page 56 Click "Test" to pop up the "Port Test Success" box to indicate that the software is connected to the device (if the "Port test failure" to check that the computer such as device WIFI is successfully connected and if IP is entered incorrectly). Confirm 10) The computer connects the mainboard (each controller has different wifi name, which can be viewed at a label on the mainboard, and the desktop computer needs to connect to the W IFI module to connect)
  • Page 57 When a device is connected to the Internet, when we have the latest version released, we can right-click on in the lower right corner of the computer and click on online" to see if the device "RDMonitor" "Upgrade devices needs to be upgraded. Web:www.rd-acs.com | TEL/FAX:0755-26066687/26982287 202-203, B-Block,Technology Building, 1057 Nanhai Avenue,Nanshan District,, SHENZHEN, CHINA 57...
  • Page 58 Chapter 8 RDCloud Application Description The main contents of this section: RDCloud Introduction Page Features Introduction Web:www.rd-acs.com | TEL/FAX:0755-26066687/26982287 202-203, B-Block,Technology Building, 1057 Nanhai Avenue,Nanshan District,, SHENZHEN, CHINA 58...
  • Page 59 8.1 RDCloud Introduction RDCloud System Enables devices to access the Internet, and users can see different data from devices on the page. This manual is the details of the user page client-side function. (1) User Center (2) Device management (3) My profile (4)...
  • Page 60 Enter the registered email and password such as:croco@nasa.com After all the account numbers and passwords have been entered, click the login button, if the account password verification correct will jump to the user center, if the empty account password login account number or password error, account number does not exist will have the prompt on the page as following figure;...
  • Page 61 8.2.2 Register If no registered account, click Sign up to jump to the registration page, as shown below. Web:www.rd-acs.com | TEL/FAX:0755-26066687/26982287 202-203, B-Block,Technology Building, 1057 Nanhai Avenue,Nanshan District,, SHENZHEN, CHINA 61...
  • Page 62 · The first column: The account number, must be the mailbox. · Second column: Click on the right to send verification code correctly · The third column: enter the nickname correctly · The fourth column: enter the contact phone number correctly ·...
  • Page 63 · The first column: enter the mailbox. · Second column: click on the right to send verification code. · The third column: Enter a new password. · Column 4: New password confirmed. Once all the input meets the requirements, click the registration button and if this account already exists, you will be having prompt, and when the registration is successful, will enter the login page.
  • Page 64 1: My applications, as shown in the image above, the user can add and cancel the application from application center. 2: Application Center, as shown in the following image. 3: User nickname, click to enter my profile, user can modify the personal information. 4: Sign out, click back to the login page;...
  • Page 65 1: On the left is the menu bar, which opens the device monitoring page by default; 2: The device nickname. 3: The connection status of the device, showing network connection info. 4: List of device operations. 5: The device operation list has editing, details and un-binding function; User can edit, un-binding, and view details of the device;...
  • Page 66 6: Add the device button and click to pop out of the following input box: Web:www.rd-acs.com | TEL/FAX:0755-26066687/26982287 202-203, B-Block,Technology Building, 1057 Nanhai Avenue,Nanshan District,, SHENZHEN, CHINA 66...
  • Page 67 Machine name, machine number, property number three items are required; It must be entering the machine number that conforms to the specification, otherwise there will be an error prompt, if the input device does not exist will be an error bullet warning. Note: Device additions must be made the first time when login to the User Center, otherwise no data showing.
  • Page 68 1: This prompt occurs when the device is not connected to the network; 2: Drop-down list to switch the devices bound with this account; 3: Current real-time equipment works information; 4: Device status statistics of the day, click on the 4-module pop up the use of the status table, as shown below, this page can use the drop-down to switch devices, by setting the time period to search for information on all the status of the time period, it can be deleted in bulk, or deleted in a single article.
  • Page 69 5: The timeline of all data for the day, click 4-module pop up the usage status table, as shown below, this page can use the drop-down to switch devices, by setting the time period to search for information on all states of the time period, it can be deleted in bulk, or deleted in a single article.
  • Page 70 The interface functions are as follows: 1: Device drop-down list to switch all devices bound to the account; 2: Search criteria, data within the start time to end time period. 3: Statistics on the number of specific causes of error and the time of the last occurrence. 4: Statistics on the number of specific alarms causes and the time of the last occurrence.
  • Page 71 8.2.8 Downtime information Click on the stop icon in the menu bar on the left and pop up the Downtime info page, as shown below. Web:www.rd-acs.com | TEL/FAX:0755-26066687/26982287 202-203, B-Block,Technology Building, 1057 Nanhai Avenue,Nanshan District,, SHENZHEN, CHINA 71...
  • Page 72 The interface functions are as follows: 1: Device drop-down list to switch all devices bound to the account. 2: Search criteria, data within the start time to end time period. 3: The length of the time column chart of the specific reason for the shutdown; 4: The chart switches with the table, which is as follows: 8.2.9 Production information Click on the production information in the menu bar on the left and pop up the production information page,...
  • Page 73 The interface functions are as follows: 1: Device drop-down list to switch all devices bound to the account; 2: Search criteria, data within the start time to end time period. 3: A column chart of production quantities during the time period; 4: Production duration chart during the time period;...
  • Page 74 8.2.10 Device comparison Click on Device Comparison in the left menu bar to pop up the device Comparison page, where the productivity, number of processes and number of alarms of several machines are displayed in tabular form, allowing user to compare the differences between each machine, as shown below.
  • Page 75 Click on the device name drop down list to select the device to be added, click on unhide to hide the pop-up box and confirm the selection of the device shown to the comparison table. 8.2.11 My profile From my application, click on my profile to view the details of the account and change the password, as shown in the following image.
  • Page 76 8.2.12 Maintenance management In my application, click maintenance management view the maintenance records of each equipment, if the equipment has a new maintenance, repair, replacement operation, click add button to record the operation of the parts, as shown in the following image: Web:www.rd-acs.com | TEL/FAX:0755-26066687/26982287 202-203, B-Block,Technology Building, 1057 Nanhai Avenue,Nanshan District,, SHENZHEN, CHINA 76...
  • Page 77 The interface functions are as follows: 1: Device drop-down list to switch all devices bound to the account; 2: Search criteria, data within the start time to end time period. 3: The same maintenance operations within a day are shown as one line of data in the table, click on details 5 to see the details, as shown below: Click on the ‘×’...
  • Page 78 Replace: User can do records and make notes for the selecting the part for the device, such as the replacement brand. 8.2.13 Maintenance and repair In my application, click On Repair service, which first appears as all added repair records under this account number, as shown below: When user need to repair, click New Repair,...
  • Page 79 First click on the Select Device drop-down list to select the device to be repaired, the repairer, company, email information is default under the account, it cannot be modified here, in the description box enter the fault-related description, click on the attachment can upload all format files (the file limit in 2MB), after filling in the click on confirm to adding, after the addition successful will automatically generate a unique Repair number .User can check the progress of this report in the status bar.
  • Page 80 attachments user can click Download to download : Remarks: Web:www.rd-acs.com | TEL/FAX:0755-26066687/26982287 202-203, B-Block,Technology Building, 1057 Nanhai Avenue,Nanshan District,, SHENZHEN, CHINA 80...
  • Page 81 Clicking on remarks to reply to this repair, it will be display in the log list. When this repair information is in the processing state, click Complete to convert the repair information to the Completed state after it has been resolved. When a repair information is not needed, you can click Delete to delete this repair information.
  • Page 82 Chapter 9 Detailed description of manufacturer/us er parameters The main contents of this section: Manufacturer parameters User parameters Web:www.rd-acs.com | TEL/FAX:0755-26066687/26982287 202-203, B-Block,Technology Building, 1057 Nanhai Avenue,Nanshan District,, SHENZHEN, CHINA 82...
  • Page 83 9.1 Manufacturer parameters (1) Motor parameters X/Y/Z/U-axis parameters ➢ Directional polarity: Modifying the directional polarity causes the motor to move in the opposite direction. The purpose of modification is to make the axis move towards the home position on reset. If the axis moves away from the home position on reset, the direction polarity of the axis is incorrectly setting and should be modified.
  • Page 84 produce whistling, if too small a setting will result in slow acceleration and reduce the overall running speed of the graph. A typical setting range is 800 to 3000 mm/s2 for axes with high inertia, such as the Y-axis corresponding to the beam, and 8000 to 20000 mm/s2 for axes with low inertia, such as the X-axis corresponding to the trolley.
  • Page 85 be higher than the maximum power value set here, the minimum power value set by the user can not be lower than the minimum power value set here If the laser is used for a period of time, the power is attenuated, then the laser power can be fine-tuned by setting the laser attenuation coefficient, which is 0 in the case of no attenuation.
  • Page 86 9.2 User parameters (1) Cutting parameters (only affects the way the cutting works) ➢ Idle speed: This parameter determines the maximum speed of all lightless straight lines during the machine's motion. ➢ Idle acceleration: The maximum acceleration of the straight lines when laser off. The idle speed and idle acceleration can shorten the working time of the entire graphic, but too large settings may lead to jitter in the trajectory.
  • Page 87 the common mode. ➢ Facula size: This parameter is invalid when the scan mode is selected in common mode, and it works when a special mode is selected. The controller controls this parameter between 50% and 99%. The cutting and scanning process parameters must not exceed the limit parameter values in the axis parameters.
  • Page 88 ➢ Whit (6) Other user parameters ➢ Array processing method: User can choose between bi-directional arrays and uni-directional arrays, which only work for virtual arrays. Bi-directional array: i.e. cutting of the array back and forth in sequence; uni-directional array: always cutting of the array from one direction to the other. When unidirectional arrays are selected, each array unit moves in exactly the same pattern, with identical smoothness of movement, but is slightly more time consuming than bi-directional walk arrays.
  • Page 89 Web:www.rd-acs.com | TEL/FAX:0755-26066687/26982287 202-203, B-Block,Technology Building, 1057 Nanhai Avenue,Nanshan District,, SHENZHEN, CHINA 89...
  • Page 90 Thank you for using Shenzhen Ruida Technology Co., Ltd. products! All parts of this note, the property rights of the works belong to Shenzhen Ruida Technology Co., Ltd., without the permission of the Company, no unit or individual may reproduce, copy or...