Download Print this page

Leakage Test - Sony PS-LX430 Service Manual

Hide thumbs Also See for PS-LX430:

Advertisement

After
correcting
the
original
service
problem,
perform the following safety check before releasing
the set to the customer:
Check the antenna terminals, metal trim, '"'metallized"'
knobs, screws, and all other exposed metal parts for
AC leakage.
Check leakage as described below.
LEAKAGE
TEST
The AC leakage from any exposed metal part to
earth ground and from all exposed metal parts to any
exposed
metal
part having a return
to chassis, must
not
exceed
0.5mA
(500
microampers).
Leakage
current
can
be
measured
by
any
one
of. three
methods.
1.
A
commercial
leakage
tester,
such
as
the
Simpson
229
or RCA
WT-540A.
Follow
the
manufacturers' instructions to use these instru-
ments.
2.
A battery-operated AC milliammeter.
The Data
Precision
245 digital multimeter is suitable for
this job.
3.
Measuring the voltage drop across a resistor by
means
of a VOM
or battery-operated AC volt-
meter.
The
"limit"
indication
is 0.75 V, so
analog
meters
must
have
an
accurate
low-
voltage
scale.
The
Simpson
250
and
Sanwa
SH-63Trd
are examples of a passive VOM
that
is suitable.
Nearly all battery operated
digital
multimeters
that
have
a
2V
AC
range
are
suitable.
(See Fig. A)
To Exposed Metal
Parts on Set
AC
0.15 uF
vo/tmeter
;
(0.75 V)
—= ~~ Earth Ground
Using an AC voltmeter to check AC leakage.
PS-LX430/430€/431/431N/433
CAUTION
ON
INSTALLING
BELT
When installing beit, glossy should be faced outside.
Motor pulley
Glossy side