Conversion Kits:  CK‐23, CK‐24, CK‐25, CK‐26, CK‐27, CK‐28, CK‐29, CK‐30 
 
 
 
WARNING
 
 
This conversion kit shall be installed by a 
 
qualified service agency in accordance with 
 
the manufacturer's instructions and all 
 
applicable codes and requirements of the 
 
authority having jurisdiction. The information 
in these instructions must be followed to 
 
minimize the risk of fire or explosion or to 
 
prevent property damage, personal injury or 
 
death.  The qualified service agency is 
 
responsible for the proper installation of this 
 
kit.  The installation is not proper and 
complete until the operation of the converted 
 
appliance is checked as specified in the 
 
manufacturer's instructions supplied with the 
 
kit. 
 
 
In Canada: 
 
 
 
The conversion shall be carried out in accordance with the requirements of the provincial authorities 
 
having jurisdiction and in accordance with the requirements of the CAN‐B149.1 and CAN1‐B149.2 
Installation Code. 
 
 
 
LA CONVERSION DOIT ÊTRE EFFECTUÉE CONFORMÉMENT AUX EXIGENCES DE L'AUTORITÉ 
 
PROVINCIALE AYANT JURIDICTION ET AUX, CSA‐B149.1, ET CAN‐B149.2.
 
*A qualified service agency is any individual, firm, corporation or company which either in person or 
through a representative is engaged in and is responsible for the connection, utilization, repair or 
servicing of gas utilization equipment or accessories; who is experienced in such work, familiar with all 
precautions required, and has complied with all of the requirements of the authority having jurisdiction. 
 
*Conversion acceptable for install locations 0‐2,000 feet.  See heater installation manual for procedures 
to adjust above 2,000 feet. 
 
NORITZ America Corporation 
11160 Grace Avenue 
Fountain Valley, CA 92708 
866‐766‐7489 
www.noritz.com 
Installation Guide
 
 
Cette trousse de conversion ne doit être 
installée que par le représentant d'un 
organisme qualifié et conformément aux 
instructions du fabricant et à tous les codes et 
exigences pertinents de l'autorité 
compétente. Les instructions de cette 
notice doivent être suivies afin de réduire au 
minimum le risque d'incendie ou d'explosion, 
de dommage matériel, de blessure ou de 
mort. L'organisme qualifié 
est responsable de l'installation adequate de 
cette trousse. L'installation n'est pas adéquate 
ni complète tant que le bon fonctionnement 
de l'appareil converti n'a pas été vérifié selon 
les instructions du fabricant fournies avec la 
trousse. 
1
WARNING
Rev. 08/17 
 
 
CK‐IM‐5 

Advertisement

loading

Summary of Contents for Noritz CK-23

  • Page 1   manufacturer’s instructions supplied with the  de l'appareil converti n'a pas été vérifié selon    kit.  les instructions du fabricant fournies avec la    trousse.    In Canada:        The conversion shall be carried out in accordance with the requirements of the provincial authorities    having jurisdiction and in accordance with the requirements of the CAN‐B149.1 and CAN1‐B149.2  Installation Code.        LA CONVERSION DOIT ÊTRE EFFECTUÉE CONFORMÉMENT AUX EXIGENCES DE L'AUTORITÉ    PROVINCIALE AYANT JURIDICTION ET AUX, CSA‐B149.1, ET CAN‐B149.2.   *A qualified service agency is any individual, firm, corporation or company which either in person or  through a representative is engaged in and is responsible for the connection, utilization, repair or  servicing of gas utilization equipment or accessories; who is experienced in such work, familiar with all  precautions required, and has complied with all of the requirements of the authority having jurisdiction.    *Conversion acceptable for install locations 0‐2,000 feet.  See heater installation manual for procedures  to adjust above 2,000 feet.    NORITZ America Corporation  11160 Grace Avenue  Fountain Valley, CA 92708  866‐766‐7489  www.noritz.com  CK‐IM‐5  Rev. 08/17 ...
  • Page 2 CK‐28 N‐0931M‐DV‐ASME/  Natural Gas to Propane  NC250‐DV‐ASME  NR83‐DVC  CK‐29  NR83DVC(GQ‐2457WS‐FFA US)  Propane to Natural Gas  NR83OD(GQ‐2457WS US)  NR83‐DVC    CK‐30 NR83DVC(GQ‐2457WS‐FFA US)  Natural Gas to Propane  NR83OD(GQ‐2457WS US)    *The model type can be verified from the rating plate located on the front cover or the right  side of case of the unit.    Tools Required:   Noritz Remote Controller   Manometer (Capable of displaying digits in tenths (e.g. 2.4) and up to 20” W.C.)   Philips screwdriver (#2 Recommended)   Gas leakage detector    NOTE: Do not attempt to perform a conversion without access to a manometer and a Noritz  Remote Controller. A digital manometer is recommended.                   ...
  • Page 3: Included Parts

    The following parts are supplied in the  2. Included Parts  conversion kit.  Check for any missing  items before starting the conversion.        Parts  Shape  Quantity            1  Manifold Plate  N‐0931M‐DV/               NR83‐DVC/  NR111‐DV and N‐0931M‐ NR83DVC(GQ‐2457WS‐FFA US)/   DV‐ASME/NC250‐DV‐ASME  NR83OD(GQ‐2457WS US)  NG/LP only   2  O‐Ring          N‐0931M‐DV/             1  Burner Damper  NR83‐DVC/  NR111‐DV and N‐0931M‐ NR83DVC(GQ‐2457WS‐FFA US)/ DV‐ASME/NC250‐DV‐ASME ...
  • Page 4 5) FOR NR83‐DVC AND NR83DVC(GQ‐2457WS‐ FFA US) ONLY:  Detach the Remote Controller  with metal plate by removing the screw. (See  image on the right)      FOR NR83‐DVC, NR83DVC(GQ‐2457WS‐FFA US)  AND NR83OD(GQ‐2457WS US) ONLY:     Locate the five colored wire connectors       (Gray, Black, Orange, Blue, and Red) from the        electrical solenoids on the Manifold Plate.   Disconnect the connector of Manifold Plate.   FOR N‐0931M, NR111, AND NC250 SERIES ONLY:       Locate the six colored wire connectors (Brown, Gray,     Black, Orange, Blue, and Red) from the electrical solenoids  Remote Controller    on the Manifold Plate. Disconnect the connector of   NR83‐DVC/    Manifold Plate.
  • Page 5               Remove    Manifold    Screw O‐Ring   BROWN  GRAY  BLACK ORANGE    Gas Pipe        O‐Ring BLUE    C‐Clamp   WHITE   (BACK) Gas Pipe FIGURE 2      FIGURE 1     9) FOR NR83‐DVC AND NR83DVC(GQ‐2457WS‐FFA US) ONLY:  Remove screw, feed back  pipe, and O‐ring from the gas valve as shown below.  These parts are used on the new ...
  • Page 6 4  3        Burner Damper for NR83 Series      Gas    Model Name  Damper Size Conversion    (EX: 10‐12H = N‐0931M‐DV‐LP) N‐0931M‐DV/NR111‐   NG to LP  10‐12H  DV,                                   Burner Damper   N‐0931M‐DV‐ASME  LP to NG  7‐14O  /NC250‐DV‐ASME for 931 / NR111 / NC250 Series   NR83‐DVC/  NG to LP  17‐11    FIGURE 4  NR83DVC(GQ‐2457WS‐ FFA US)/  LP to NG  17‐12    NR83OD(GQ‐2457WS US)  11) Replace the O‐rings on the Gas Pipe to New  O‐rings included in Conversion Kit. Discard  ...
  • Page 7 13) Make sure that O‐rings are secured properly in place.  Failure to do so will cause gas  leaks, possibly resulting in severe personal injury or death.    14) Once O‐rings are attached, slide the Gas Pipe into the Manifold inlet.  Make sure that  the Gas Pipe is completely inserted into the Manifold inlet in order to prevent any gas  from leaking.    15) Insert Gas Pipe into the gas supply inlet and hold the Manifold Plate in place.    16) Secure the new Manifold Plate to the unit using the screws removed in Step 8.  The  screws need only to be hand tightened and should not be tightened by using a power  drill.  First, insert screws 1‐4 from Figure 1, but do not fully tighten these screws.  Once  all screws are inserted, proceed to completely tighten screws 1‐4.    Note:  When tightening the screws, be certain to not apply excess force as the screws should  turn easily.  If extra force is required, stop, remove the screw and tighten by hand first.  Excess  force can strip out the original holes.      17) Attach C‐Clamp at the bottom of the Gas Pipe (Figure 2).  Failure to do so will cause gas  leaks, possibly resulting in severe personal injury or death.      18) Connect the connector ‐ Manifold Plate (Figure 1).    19) FOR NR83‐DVC AND NR83DVC(GQ‐2457WS‐FFA US) ONLY: Attach the O‐ring, feed back  pipe, and screw on the Gas Valve as shown in Figure 3. Then attach the Remote  Controller with screw.    20) Before replacing the Front Cover, the unit must be adjusted and tested as described in  the next section.    Adjustments:    1) Before electrical power is applied to the unit, install a Remote Controller to the unit if it ...
  • Page 8 “ON” setting for that item number, and if the Priority lamp is off, the item number is  “OFF”.    5) Change “FC” and “FE” from OFF to ON. The priority light should be flashing on both item  numbers after pressing the “FLOW METER ALARM SET”.    6) Choose the proper conversion setting from the chart and set the “A1” Maintenance  Writer item number according to the chart.    Note: DO NOT change any other item.  This will cause a fault on the unit.    Desired Gas Type  Natural Gas  Propane    ON: “Priority” light is flashing.  OFF: “Priority” light is off.    7) After setting the “A1” item number for the desired gas type, press and hold the “up”  and “down” buttons together for five seconds to confirm the new settings.  The Remote  Controller will sound and the display will go blank when the settings are confirmed.  If  this is not done, the unit will not put the setting changes into effect.      Note:  The setting changes can be cancelled by pressing the Power ON/OFF button  before confirming the settings, or if the unit is left alone for ten minutes without  confirming the settings.  If the default setting needs to be changed again, disconnect the  electrical power to the unit, reconnect it and repeat this procedure.        Testing:    1) Before turning on the gas supply to the unit, verify that the inlet gas supply pressure is  within the following operating ranges:    FOR N‐0931M, NR111, AND NC250 SERIES ONLY:  a. Natural Gas Supply: Min. 5.0 – Max. 10.5 inches W.C.  b.
  • Page 9 2) Next, verify the supply pressure at the unit.  To check  the gas supply pressure to the unit, a tap is provided on  the gas inlet (Figure 7).  Make sure gas supply is turned  off to the unit.  Remove the hex head Philips screw from  the tap.  A 9/32” nut driver is recommended for the  removal of this screw. If a nut driver is not available,  a Philips screwdriver can be used. Gently remove the  screw, so as not to strip out the screw.    3) Connect a manometer to the tap by using a silicone  tube. Turn on gas supply to the unit and confirm the  FIGURE 7  supply pressure.   4) After checking the gas pressure to the unit has been confirmed, turn off the gas supply,  remove the manometer tube and replace the hex head screw.           5) Check the Manifold pressure by using a manometer  (digital manometer is recommended).  In order to  check the gas Manifold pressure, a tap is provided  on the Manifold Plate inside of the unit (Figure 8).   The pressure can be checked either by removing the  hex head Philips screw (1) and connecting a  manometer with a silicon tube, or by removing the  1/8” NPT screw (2) with an Allen wrench and  connecting the appropriate pressure gauge. Be sure  to zero out the manometer before attaching it to  931 / NR111 / NC250 Series      the tap.    6) Turn on the gas supply to the unit.     7) Before operating the unit, check for gas  leaks at the gas inlet fitting and around the ...
  • Page 10 10) Once the heater has ignited and has begun to run  continuously, locate the Manifold adjustment buttons  on the circuit board located in the right side of the unit   (Figure 9).    11) Press and hold the maximum pressure set button.  Verify from the below table that the appropriate  pressure is read from the manometer.  If the pressure  needs adjustment, use the Manifold pressure increase  and decrease buttons to adjust to the correct pressure,  while continuing to hold down the maximum pressure  set button.    12) Press and hold the minimum pressure set button.   Verify from the tables below that the appropriate  pressure is read from the manometer.  If the pressure  needs adjustment, use the Manifold pressure increase  and decrease buttons to adjust to the correct pressure,  while continuing to hold down the minimum pressure  FIGURE 9  set button.    Manifold Gas Pressure Maximum and Minimum Values    Supply Pressure  Manifold Pressure (inch H O) Cover Off  Model Name  Gas Type    (inch H O)  Max Value  Min Value  N‐0931M/NR111‐SV,  NG   7.9  3.46 ...
  • Page 11                                                     13) After the Manifold pressures have been  confirmed, verify that the flame is a steady blue  color using the inspection window (Figure 10).    14) Turn off water and gas to unit. Attach screw  to Manifold tap and turn on gas supply to the  unit.    15) Perform a final gas leak check around the                       FIGURE 10 entire Manifold Plate, especially near the Gas  Pipe and Manifold inlet, using a gas leak  detection device.    16) If the Remote Controller needs to be removed,  disconnect electrical power to heater and  proceed to remove controller connections.                             ...
  • Page 12 Apply conversion labels:    1) Close the Front Cover of the unit with 4 screws previously removed.    2) Locate the 2 conversion stickers in English supplied in the conversion kit.  *For units  certified for use in Canada locate the 2 conversion stickers in French.      3) Place the sticker indicating the new inlet and Manifold pressures directly above the  rating sticker so as not to cover any existing markings as indicated by “A” in Figure 11.  *For units certified for use in Canada place French sticker with new pressures next to  English sticker.     4) Fill out the required information on the remaining sticker indicating the date, gas type,  kit number, and name of the company performing the conversion.  Place this sticker on  the front cover as indicated by “B” in Figure 11.  Do not to cover any existing markings.  *For units certified for use in Canada place French sticker with agency information  next to English sticker.                                (N‐0931M/NR111‐SV & ASME Model)     (N‐0931M‐DV/NR111‐DV & ASME Model)           (N‐0931M‐OD/NR111‐OD)                                  NR83OD(GQ‐2457WS  US) NR83‐DVC  NR83DVC (GQ‐2457WS‐FFA US)  FIGURE 11...
  • Page 13 Installation Checklist:    Parts Replacement:    □ Remove existing Manifold Plate, Burner Damper and O‐rings.  Discard these parts.  □ Replace with new Manifold Plate, Burner Damper and O‐rings.  □ Make sure that Manifold Plate and O‐rings are secured properly in place.    Adjustments:    □ Access Maintenance Writer mode and set the A1 item number to desired gas type.   □ Confirm gas type settings.    Testing:    □ Before opening gas valve to the unit, verify the gas supply pressure is within operating  range of the uint.  □ If gas supply pressure is not within specification, adjust the pressure at the regulator or  install a secondary regulator on the supply line connected to the unit.  □ Remove hex Philips screw from inlet of the unit and confirm gas supply pressure with  manometer. Replace screw after confirmation of gas supply pressure.  □ Remove hex Philips screw or 1/8” NPT screw from gas valve and connect manometer to  Gas Valve.  □ Check for gas leaks around gas inlet fitting and Manifold Plate using a gas leakage  detector.  □ Check and confirm correct Manifold pressures. Make adjustment if necessary. Replace  screw after Manifold pressures have been confirmed.  □ Perform final gas leak check again with gas leakage detector.   ...

This manual is also suitable for:

Ck-24Ck-25Ck-26Ck-27Ck-28Ck-29 ... Show all