5.
When motorized couplant pump use is complete, close the flow control valve
(rotate clockwise) and turn the power switch OFF.
6.
Depressurize the system before transporting.
a.
Ensure the pump is unplugged from a
power source and the power switch is
OFF.
b.
Disconnect the irrigation kit from the
outlet.
c.
Disconnect the inlet hose (Fig. 5-1) and
insert the inlet hose into the outlet
(Fig. 5-2).
d.
Open the flow control valve until all the
pressure is released from the system.
Chapter 5
MAINTENANCE AND SUPPORT
1.
The motorized couplant pump should be serviced by qualified personnel only.
Always disconnect the power source before servicing.
2.
For technical support, contact JIREH.
Chapter 6
TROUBLESHOOTING
Problem
Possible Cause
The pump does
The flow control valve is not
not discharge
opened, the power switch
fluid
is not turned on, the power
source is disconnected, inlet/
outlet connections are not
attached, inlet filter is not
placed in a fluid.
Pump flow
Hose kinked, hose split, inlet
inconsistent
filter plugged.
Chapter 7
SPARE PARTS
BOM ID Part #
Description
1
CMS038
Inlet Filter
2
LA021
Inlet Hose
3
LA081
Quick Connect Fitting: 7/16 in
4
CMS037
Motorized Pump Inlet Tube
4
1
- Inlet hose spare parts
Fig. 6
1
- Pump Assembly
Fig. 5
Solution
Ensure the flow control valve is rotated
counter-clockwise, the power switch is
turned on, the power cord is plugged into
a live source, inlet/outlet fittings are fully
inserted, inlet filter is submerged in the
fluid reservoir.
Ensure houses are not split or kinked, and
remove/replace the inlet filter.
3
Jireh Industries Ltd.
2
53158 Range Road 224
Ardrossan, Alberta
780.922.4534
jireh.com
2
Canada
T8E 2K4
MOTORIZED
COUPLANT
PUMP
CM0061 Rev 02.4

Advertisement

loading

Summary of Contents for Jireh MOTORIZED COUPLANT PUMP

  • Page 1 When motorized couplant pump use is complete, close the flow control valve (rotate clockwise) and turn the power switch OFF. Depressurize the system before transporting. Ensure the pump is unplugged from a MOTORIZED power source and the power switch is OFF.
  • Page 2 (rotate counter-clockwise) until the desired 2.3. Operating Environment flow is achieved (Fig. 4). The motorized couplant pump is designed for use in an industrial environment that is Close the flow control valve (rotate clockwise) to stop the fluid flow. between -20° C (-4° ...