KV-20EXR20
RM-Y103
SAFETY
CHECK-OUT
(US Model only)
To Exposed Metal
Parts on Set
AC
voltmeter
lime] (0.75)
=
Earth Ground
Fig. A.
Using an AC voltmeter to check AC leakage.
LEAKAGE
TEST
The AC leakage from any exposed metal part to
earth ground and from al} exposed metal parts to any
exposed
metal part having a return to chassis, must
not
exceed
0.5mA
(S00
microampers).
Leakage
current
can
be
measured
by
any
one
of
three
methods.
1.
A
commercial
leakage
tester,
such
as
the
Simpson
229 or RCA
WT-S40A.
Follow the
manufacturers' instructions to use these instru-
ments.
2.
A battery-operated AC milliammeter.
The Data
Precision 245 digital multimeter is suitable for
this job.
3.
Measuring the voltage drop across a resistor by
means
of a VOM or battery-operated AC volt-
meter.
The
'limit'
indication
is 0.75V,
so
analog
meters
must
have
an
accurate
low-
voltage
scale.
The
Simpson
250 and Sanwa
SH-63Trd
are examples of a passive VOM that
is suitable.
Nearly all battery operated
digital
multimeters
that
have
a
2V
AC
range
are
suitable.
(See Fig. A)
Trouble Light
Ohmmeter
= AC Outlet Box
Cold-water Pipe
Fig. B.
Checking for earth ground.