Advertisement

Quick Links

Ecological Boilers VIGAS
MANUAL FOR INSTALLATION, ASSEMBLY AND USE
VIGAS 25 TVZ
with control AK 3000
Certificate of warranty
Gasifying boilers VIGAS
WARNING
Never operate boiler without energy or
without cooling fan. ( If boiler is not
cooled, corpus of the boiler can be
damaged )!!!
1
VIMAR 2011

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VIGAS 25 TVZ and is the answer not in the manual?

Questions and answers

Summary of Contents for Vimar VIGAS 25 TVZ

  • Page 1 Gasifying boilers VIGAS Ecological Boilers VIGAS MANUAL FOR INSTALLATION, ASSEMBLY AND USE VIGAS 25 TVZ with control AK 3000 Certificate of warranty WARNING Never operate boiler without energy or without cooling fan. ( If boiler is not cooled, corpus of the boiler can be...
  • Page 2: Table Of Contents

    Gasifying boilers VIGAS Content Strana Declaration of conformity ..................... 1. Technical description...................... 2. Technical data......................... 3. Description of AK 3000 control ..................4. VIGAS TVZ boiler in basic configuration................. 5. VIGAS TVZ boiler in configuration with discharge fan........... 6. Temperature of output air setting..................7.
  • Page 3: Declaration Of Conformity

    The validity of this statement is lost when an unauthorized changes are done without permission of VIMAR. Product: Hot – air boiler VIGAS TVZ with AK 3000 control...
  • Page 4: Technical Description

    Gasifying boilers VIGAS 1. TECHNICAL DESCRIPTION Hot-air boilers, VIGAS are designed for combustion of dry wood material, starting from sawdust up to logs in the length according to the dimensions of gasification chamber, maximum 20 cm. Sawdust, chippings, splinters and cuttings must be burn together with logs. Boilers are welded from 4- 6 mm steel sheets.
  • Page 5: Technical Data

    Gasifying boilers VIGAS 2. TECHNICAL DATA Technical data HOT AIR BOILER VIGAS 25 TVZ VIGAS Nominal boiler output Boiler class according to EN 303-5 Fuel Wood heating min. 15 MJ/kg Output capacity 5-28 Fuel consumption with nominal kg/hod output. Efficiency...
  • Page 6 Gasifying boilers VIGAS 2.1 DIMENSION CHART AND THE POSITION OF PROTECTIVE SUPPORT PLATE ON EASILY IGNITABLE FLOOR Pic.2 Pic.1 2.2 BOILER SCHEMATIC Scheme VIGAS 25 TVZ Pic.3 11. Door closing device 22. Exchanger pipes 1. AK 3000 control 12. Fireclay bricks 23.
  • Page 7: Description Of Ak 3000 Control

    Gasifying boilers VIGAS 3. DESCRIPTION OF AK 3000 CONTROL 3.1 Safety Instructions Check protection (cover) metal sheet before plug-in the power wire Avoid any contact of power wire with hot parts of the boiler (f.e. chimney) Make sure, no water is allowed under the upper isolation (risk of short circuit) Do not stress the power wire Always disconnect the power wire when a new electrical components are connecting (f.e.
  • Page 8 Gasifying boilers VIGAS Functionality of each button are composite and their functionality depends accompanying description on display and from manufacture settings. Pic.7 1. Real time indication. 2. Indication of current boiler values. Modification ▲ or 3. Indication od discharge fan, gases thermometer 4.
  • Page 9: Vigas Tvz Boiler In Basic Configuration

    Gasifying boilers VIGAS 4. VIGAS TVZ BOILER IN BASIC CONFIGURATION (without discharge fan ) VIGAS TVZ BOILER OPERATING 4.1 4.1 Boiler activation If boiler is in unactive status with symbol „OFF“, as displayed on the picture, by pressing the central button ENTER the boiler start the operation.
  • Page 10: Vigas Tvz Boiler In Configuration With Discharge Fan

    Gasifying boilers VIGAS 4.5 Disconnection the boiler (Automatically) When temperature drops under the shotdown temperature (see Parameter settings of Vigas TVZ boiler ) boiler is switch-off automatically. „END“ will be indicated on the display. By pressing „ENTER“ boiler will start operating again. 5.
  • Page 11: Temperature Of Output Air Setting

    Gasifying boilers VIGAS Boiler activated – burning mode The burning mode is active after the gases temeprature is higher end) + 20 C. In this mode pump is working pulse (bolier protection against low-temperature corrosion). The pump is working, when symbol flash. Boiler is responsive to indoor thermostat, when indoor thermostat is switched off boiler slowly decreasing its output.
  • Page 12: Parameters Settings For Vigas Tvz Boiler

    Gasifying boilers VIGAS 7. PARAMETERS SETTINGSOF VIGAS TVZ BOILER To call parameters setting hold „ENTER“ button at any boiler status and by pressing ▲ button. Press „ENTER“ again Symbol of the parameters setting will be indicated on the display. By pressing the „ENTER“...
  • Page 13: Hardware And Software Information

    Gasifying boilers VIGAS 9. HARDWARE AND SOFTWARE INFORMATION To call informations setting hold „ENTER“ button at any boiler status and by pressing button. ▲ buttons choose modul and confirm „ENTER“. Information about the module will be indicated on display. 10. ERROR MESSAGES To call error messages hold „ENTER“...
  • Page 14 Gasifying boilers VIGAS 11.1 Settings for micro SD card AK 3000 control can be extenended by SD modul (Pic.8). Micro SD card of different capacity is plugged into SD module. Micro SD card allows: Pic.8 Loading of back-up software to control unit of the boiler Software back-up to SD card Loading of updated software from SD card to control unit of the boiler...
  • Page 15: Operating Instructions

    Gasifying boilers VIGAS 11.3 Control of service settings Funcionality of each system can be check in service settings by symbols indicated on display. Press „ENTER“ and selected system will be activated. 12. OPERATING INSTRUCTIONS 12.1 Before operation: ▪ to be informed with operating instructions and how to operate the electronic control AK 3000, ▪...
  • Page 16 Gasifying boilers VIGAS 12.3 Keeping operation and output regulation Fuel in boiler is moved spontaneously in the direction to fireproof nozzle. Ash falls through nozzle and deposits in combustion chamber. Boiler output is regulated automatically according to the set temperature of outlet water. If there is mains failure during a longer period of time or if automatic regulation fails, it is not possible to heat .
  • Page 17 Gasifying boilers VIGAS 12.5 Boiler cleaning wood burning optimal minimum Primary air hole temperature of return water is kept, 60°C, gasification chamber, completing combustion space and exchanger are sooted minimally. If wet fuel is used, steam is condensed on the walls of combustion chamber and tar is created on surface.
  • Page 18: Boiler Maintainance And Repairs

    Gasifying boilers VIGAS Air piping cleaning The clearness of boiler piping system is a necessary condition for right burning. If you mainly use sawdust, it is necessary to clean the piping system once per heating season. After putting fan cover (8) picture 3 and sheet cover of piping away, you will get access to two pipes.
  • Page 19: Accesories Assembly

    Min A Min B VIGAS 25 TVZ 160 mm Drawning with dimmensions for V25 and V80 available on www.vimar.sk 14.2 Indoor thermostat Comfort is increased with indoor thermostat connection. Indoor thermostat is connected to mother board AK 3000S. Jumper is on T3 contact, standardly.
  • Page 20: Listo Fo Guarantee And Afterguarantee Services

    15. LIST OF GUARANTEE AND AFTER GUARANTEE SERVICES In order quality and safe operation might be kept, repairs of boiler must be done by authorized specialists VIMAR Vigaš Pavel, Príboj 796, Slovenská Ľupča, tel. 00421 48 41 87 022. tel. 00421 48 41 87 159 mail: vimar@vimar.sk...
  • Page 21: Assembly Instruction

    Gasifying boilers VIGAS 17. ASSEMBLY INSTRUCTION Recommended schema of basic connection with AK 3000 regulation. 1. VIGAS TVZ boiler 2. Discharge fan V25 3. Indoor thermostat 4. Pipe distributor 17.1 Assembly and maintainance instructions Boiler can only be connected to the system whose thermal capacity correspond with boiler output.
  • Page 22 Gasifying boilers VIGAS 17.2 Safety regulations for control and maintenance of VIGAS TVZ boiler electric equipment The boiler operator must follow relevant regulations and standards, as well as the following principles: If boiler is in operation, none of the following may be done with electric equipment: o uncover electronic equipment, e.g.
  • Page 23: Electric Scheme Of Connection Vigas Boilers

    Gasifying boilers VIGAS 18. ELECTRIC SCHEME OF CONNECTION VIGAS TVZ BOILERS Flow diagram of basic connection VIGAS TVZ boiler with AK 3000 1. Discharge fan, power supply 230 VAC / 0,6A 2. Cooling fan, power supply 230 VAC / 370W 3.
  • Page 24: Letter Of Guarantee

    Gasifying boilers VIGAS LETTER OF GUARANTEE Certificate of Quality and Completeness VIGAS TVZ kW Product Serial number : The producer confirms that the boiler comply with the standards, STN EN 61010-1+A2:2000, STN EN 50081-1:1995, STN EN 50082-1:2002, STN EN 61000-3-3:2000, STN EN 61000-3-2:2000+A1+A2:2001. Production inspection date Stamp a signature of producer Date of sale...
  • Page 25: Confirmation Of Vigas Boilers Commissioning

    Gasifying boilers VIGAS Confirmation of VIGAS TVZ boiler commissioning Product VIGAS Production No. / Year of production Date of sale Date of commissioning Stamp and signature of Signature of serviceman Name and adress of user: When commissioning, we did the following: ▪...
  • Page 26 Gasifying boilers VIGAS...
  • Page 27 Gasifying boilers VIGAS Records of electric equipment connection (discharge fan, indoor thermostat, etc. Date Equipment Name of Certificate No. Signature of serviceman serviceman Records of guarantee and after guarantee repairs Date Record od repair Name of Certificate No. Signature of serviceman serviceman Notes...
  • Page 28 VIMAR Vigas Pavel Priboj 796 976 13 Slovenska Lupca SLOVAKIA tel.: 00421 48 4187 022 fax: 00421 48 4187 159 WWW.VIMAR.SK vimar@vimar.sk All technical changes are reserved for VIMAR 2011 ver.1 Pictures are illustrative and might be different from the reality!

Table of Contents