ABC-600
4.0 Channel B Voltage Calibration:
4.1 Set Channel B for the following limits:
Voltage: 600V, 0V
4.2 Set Channel B in Voltage mode at 8V. Adjust R312 (BLOCAL) offset till DMM1 reads 8.0000.010V.
4.3 Connect Remote Voltage Sense connector from the shunt to the Channel B RVS connector on the front panel
of the ABC-600. Turn RVS mode ON.
4.4 Set Channel B in Voltage mode at 8V. Adjust R316 (BREMOTE) offset till DMM1 reads 8.0000.010V.
4.5 Command 600V from ROS. Adjust R55 such that both local and remote readings for 600  0.250V. This may
require going back and forth between local and remote modes.
5.0 Channel A Current Offset Calibration:
5.1 Set channel A and B for the following limits:
Voltage: 600V, 0V
5.2 Put Channel B in voltage mode at 100V and Channel A in current mode at 0A.
5.3 Set the DMM to mV (1mV = 1A for the shunt rating: 500A/500mv)
5.4 Adjust R71 till the DMM connected to the current shunt must reads 0.000.01mVDC.
6.0 Channel B Current Offset Calibration:
6.1 Set channel A and B for the following limits:
Voltage: 600V, 0V
6.2 Put Channel A in voltage mode at 100V and Channel B in current mode at 0A.
6.3 Set the DMM to mV (1mV = 1A for the shunt rating: 500A/500mv)
6.4 Adjust R94 till the DMM connected to the current shunt must reads 0.000.01mVDC.
22394-76_02.docx
Current: +20A, -20A
Current: +200A, -200A
Current: +200A, -200A
Page 16 of 20
Installation Instructions
Power: +1Kw, -1Kw
Power: +75Kw, -75Kw
Power: +75Kw, -75Kw
Webasto Charging Systems, Inc.