SYSTEM CONTROL TIMING CHARTS
Mode SW : LD-SW
LD-SW Position detection
A/D Input voltage Limit
Symbol
(Calculated voltage)
3.76V~4.50V
(4.12V)
EJ
4.51V~5.00V
0.00V~0.25V
(0.00V)
1.06V~1.50V
0.66V~1.05V
(oot)
1.99V~2.60V
ea)
1.51V~1.98V
(204)
3.20V~3.75V
(a)
0.26V~0.65V
(av)
4.51V~5.00V
(5.00V)
2.61V~3.19V
EJ =
RS: Loading FWD (LM-FWD "H", LM-REV "L")
RS =>
EJ: Loading REV (LM-FWD "L', LM-REV "H")
Stop (A) = Loading
Stop (B) = Unloading
Note:
Stop(A) ~ Play / REC
Play / REC ~ Siill / Slow
Still / Slow ~ RS (REW Search)
RS (REW Search)
1-15-1
H9720Tl