Advertisement

PART NUMBER
SERIAL NUMBER
D10 Inflator
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or
property damage! Retain instructions for future reference.
Safety Guidelines
This manual contains information that is very important to know
and understand. This information is provided for safety and to
prevent equipment problems. To help recognise this information,
observe the following symbols.
Danger indicates an imminently hazardous
situation which if not avoided WILL result
in death or serious injury.
Warning indicates a potentially hazardous
situation which if not avoided, COULD
result in death or serious injury.
Caution indicates a potentially minor or
moderate injury.
Notice indicates important information,
that if not followed, may cause damage to
equipment.
Unpacking
After unpacking the unit, inspect carefully for any damage that
may have occurred during transit.
Do not operate unit if damaged during
shipping, handling or use.
General Safety Information
The operator of this product must take the necessary precautions
to prevent the level of danger indicated by these symbols. The
operator is required to read and understand this instruction
manual and all safety warnings, labels etc.
Any employer allowing the use of this product in their field of work
must distribute this instruction manual to all users. The employer
must also ensure all users read, understand and follow the
instructions as described in the manual, safety warnings, labels,
etc.
76376 Issue 5
Quick Start Manual
www.pclairtechnology.com
Actual decal may vary by individual part number.
Read and understand all safety warnings
and instructions before operating this
product. Failure to read and follow all
safety warnings may result in serious
personnel injury or death. Property
damage and/or product damage may also
occur if all warnings are not followed.
1.
Do not expose the product to flammable gases,
vapours or fumes
2.
Do not store flammable gases in or near this product
3.
Never use flammable or toxic solvents to clean the
product or any of the unit's parts
4.
Never remove or alter any safety warning labels, tags,
etc. located or provided with product.
5.
Follow all directions for maintenance.
The use of other than genuine PCL
replacement parts may result in reduced
equipment performance. Repairs must be
performed by authorised repair personnel,
otherwise the warranty will be void.
Image shown is PCL standard decal.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the D10 and is the answer not in the manual?

Questions and answers

Summary of Contents for pcl D10

  • Page 1 Follow all directions for maintenance. Any employer allowing the use of this product in their field of work The use of other than genuine PCL must distribute this instruction manual to all users. The employer replacement parts may result in reduced must also ensure all users read, understand and follow the equipment performance.
  • Page 2: Installation

    70kpa above the intended maximum inflation range. Note: Key legend above is for standard PCL decal, symbols used may The wall-installed device has to be tightened to the wall by vary by individual part number but functionality remains the same...
  • Page 3: Standard Operation

    Display will show Program model variant '300' ( psi default) or '302' (bar default) Display will show the application, 'Std' After 10 seconds the display will show 'PCL' The unit will then display the set default pressure Do not connect the hose to the tyre during start-up or E5...
  • Page 4 PCL ACCURA D10 Tyre Inflator This page is intentionally left blank www.pclairtechnology.com...
  • Page 5: Service & Maintenance

    Each person who is involved with installation, start-up, maintenance and the operation of the unit must read and understand the complete operating manual. The PCL tyre inflators are exclusively approved for the dispensing of air/N . Each use which doesn't follow this purpose as well as modifications to the product will be deemed to be improper use.
  • Page 6 PCL ACCURA D10 Tyre Inflator Trouble Shooting Guide/Error Messages Problem Possible Cause Solution No display No power connected Switch power on No inflation process Tyre is below 3 psi Press flat tyre button Faulty connector Replace faulty connector Buzzer does not sound...
  • Page 7 FITNESS FOR A PARTICULAR PURPOSE. Determination of the suitability of the unit for the use contemplated by the customer is the sole responsibility of the customer. PCL shall not, under any circumstances, be liable in contract, tort or otherwise (including negligence and strict liability) for indirect, special, incidental, or consequential damages, and PCL's total liability shall not exceed the net purchase price for the unit.
  • Page 8: Calibration Certificate

    Calibration Certificate Each unit, before release, is checked and calibrated on test equipment that has accuracy traceable to Druck pressure indicator S/N2329290. The Druck unit is referenced to Certificate 0029346 issued by UKAS Laboratory No. 0221. This accuracy exceeds BS EN 12645:1999 (MPE = 0.08 bar). ACTUAL READING SET PRESSURE...

Table of Contents