The JA-154J MS II Bi-directional four-button key fob
Acoustic indication
Acoustic indication can be completely disabled. Default is enabled.
When any button is pressed it is followed by short acoustic signal
according to the table 2.
Caution: When a reaction for pressing buttons (A+B)
or (C+D) simultaneously is set (for example a panic alarm or
garage door control), it is necessary to mind that the action
is performed first.
The acoustic indication can be disabled by simultaneously pressing
and holding the pair of buttons (A+B) or (C+D) until the yellow LED (1)
starts flashing briefly for the second time, usually in 6 s. When the
yellow LED (1) flashes a second time release the button (B) and press it
again. The acoustic indication is then disabled and confirmed by flashes
of the yellow LED and a one beep. After this confirmation release all
buttons.
The acoustic indication can be enabled by repeating the procedure
above. Activation is confirmed by a double flash of the yellow LED and
a double beep.
LED indication table
Action
Pressing the button is always indicated by a very short flash of the
yellow LED and followed by flashing of the coloured LED according to
the performed action.
The mentioned indication statuses are valid for the remote's default
setting.
Unsetting
Setting
Partial setting
Unsetting after an
Control
alarm
function with
confirmation
Delayed panic
by LED
Setting confirmation
request
Partial setting
confirmation request
Pressing of button with no function
or lost communication
Low battery
Holding the button – Copy PG
Table 2. Remote control indication
If the remote control is out of the RF range
of the radio module or MPR, it doesn´t
indicate status change or signal loss.
JA-154J MS II
Indication
2 s flash of green LED
and 2x short acoustic signals
2 s flash of red LED
and 1x short acoustic signal
2 s flash of yellow LED
and 1x short acoustic signal
2 s flash of green LED
and 3x short acoustic signals
Flashing of red LED
until action is done or its
cancelling
Flashing of red LED
until confirmation (max. 8 s)
Flashing of yellow LED
until confirmation (max. 8 s)
Short flash of yellow LED
1x short acoustic signal
Flashing of yellow LED
3x short acoustic signals
1x short acoustic signals,
red LED lights for whole
period of button being
pressed
2 / 2
Battery replacement
Low battery indication is signalled on the remote control after any
button is pressed. The action assigned to the button is done and the
yellow LED flashes with 3 quick beeps. Low battery information is also
sent to the control panel. The remote still works as usual but the RF
range goes slowly down. Low battery indication is cancelled when
a new battery is inserted.
To change the battery, unscrew the 2 screws from the back plastic;
remove the cover with the metal strut from the housing and remove the
discharged battery. Then press any button a few times to discharge the
rest of the energy from the capacitors and insert a new battery.
Battery replacement DOES NOT RESET the keyfob settings nor
the locks nor the acoustics.
Don´t throw the used battery into the trash but take it to a suitable
recycling station.
Technical specifications
Compatible with:
FW of the JA-11xR radio module LR6x613+
Power – lithium battery
(Power supply C type according to EN 50131-6)
Current consumption:
- Nominal consumption
- Maximal consumption
Low battery voltage detection
Typical battery lifetime
Communication frequency
Maximum radiofrequency output (ERP)
RF range
Dimensions
Weight with no battery
Classification
Environment
Operational temperature range
Humidity
Number of unique production codes
Certification body
Additionaly in compliance with
EN 55032, EN62368-1, EN50581, EN 50131-1, ČSN EN 50131-3,
Can be operated according to
JABLOTRON ALARMS a.s. hereby declares that the JA-154J
MS is in a compliance with the relevant Union harmonisation
legislation:
Directives
2014/30/EU, 2011/65/EU. The original of the conformity
assessment can be found at www.jablotron.com - Section
Downloads.
Note: Although this product does not contain any harmful
materials we suggest you return the product to the dealer or
directly to the producer after use.
EN | English
FW of the control panel LJ(MD)60416+
F-Link 1.4.0+
type CR 2032 (3.0 V/0.2 Ah)
1,1 μA
33 mA
≤ 2.2 V
approx. 2 years (10 activations/day)
868.1 MHz
2 mW
approx 100 m (line of sight)
77 x 36 x 15 mm
Security grade 2/environmental class II
in accordance to EN 50131-1)
indoor general
-10 °C to +40 °C
75 %, no condensation
> 1 million
Trezor Test s.r.o. (no. 3025)
ETSI EN 300 220-1,-2, EN 50130-4
EN 50131-5-3, EN 50131-6
ERC REC 70-03
No:
2014/53/EU,
2014/35/EU,
MMJ25100
35 g

Advertisement