Maintenance
Filter elements are subject to wear. In order to maintain system efficiency, optimal
performance and best gas quality, these rules of proper maintenance should be followed:
• Replace filter elements P, R, M, S at least once per year or when pressure drop
reaches 350mbar.
• A filter element must be changed after 6 months.
• B filter element can be cleaned with ultrasonic bath or with back flushing. Intervals of
cleaning depend on application. If necessary replace filter element with new one.
The housing O-ring can be damaged during filter element change. To prevent gas leakage
•
and malfunction replace housing O-ring if necessary. For replacement contact
manufacturer.
Damaged components are to be replaced by new ones. If a marked degree of damage is
•
found, the entire filter is to be replaced.
Filter has been designed for a life of 10 years in normal operating environment. After 10
•
years periodical checks of filter integrity are strongly recommended for safe operation.
Carry out a check for leaks once the maintenance work has been finished.
•
Warranty exclusion
The guarantee shall be void if:
• The operating instructions were not followed with respect to initial commissioning
and maintenance.
• The unit was not operated properly and appropriately.
• The unit was operated when it was clearly defective.
• Non-original spare parts or replacement parts were used.
• The unit was not operated within the permissible technical parameters.
• Unauthorised constructional changes were made to the unit or if parts of the unit
that may not be opened were dismantled.