Rear Panel Controls - Kenwood TS-700SP Operating Manual

2m all mode transceiver
Hide thumbs Also See for TS-700SP:
Table of Contents

Advertisement

KENWOOD
3-3.
REAR
PANEL
CONTROLS
@
ANT TERMINAL
For connection
of an antenna
@
NAME PLATE
TS-700SP
serial number is marked on this plate
@
TRANSISTOR
PROTECTIVE
COVER
The transistors in the AVR
(Automatic Voltage Regulator)
circuit for 11V and 20V lines are protected by this cover.
It
also functions as a heat sink for these transistors
@
TONE
PAD
CONNECTOR
The connection
is shown on page
16 Fig. 9 of the tone pad
instruction
©
RL-MAKE
CONNECTOR
This is a normal
opened
relay contact.
It is grounded
in
transmit
©
KEY JACK
This jack is used for operating the transceiver in CW mode
Connect an external telegraph key.
@
EXT SP TERMINAL
For connection of an external 82 speaker
ALC-INPUT
CONNECTOR
External ALC connector
from a linear amplifier.
10
2A AC 120V
1A AC220V
mavelin
@
AC POWER
SELECT
SWITCH
Set this switch
to your local AC
line voltage.
When
the
switch setting is changed, be sure to replace the fuse with
one of proper valve.
(120V
=
2A. 220V
=
1A).
(9
POWER
CORD
JACK
For connection
of the supplied AC or DC power cord.
() AC FUSE HOLDER
AC primary power fuse.
(120V/2A or 220V/1A.)
(2
EXT VFO CONNECTOR
For connection
of the remote VFO, VFO-700S
(optional).
When the VFO-700S
is not used, be sure to keep the 9-pin
MT plug installed.
If not, the TS-700SP
will not work,
either transmit or receive.
(3 HEAT SINK (For Transmitter Final Stage)
Dissipates heat from the RF power
amplifiers.
(
GROUNDING
To prevent electric shock, TV! and BCI, be sure to wire the
TS-700SP
to a good earth ground.
Use grounding wire as
thick and short as possible.
Bury a ground rod or plate as
deep as possible.
Do not use gas pipes for ground!
C

Advertisement

Table of Contents
loading