Download Print this page

HP 415E Operating And Service Manual page 42

Swr meter
Hide thumbs Also See for 415E:

Advertisement

Model 415E
Section VI
Paragraphs 6-1 to 6-6
SiCTSON VI
REPLACEABLE PARIS
6-1. INTRODUCTION
6-2.
This section contains information for ordering-
replacement parts.
Table 6-1 lists parts in alpha-
numerical order of their reference designators and
indicates the description and hp stock number of each
part, together with any applicable notes.
Table 6-2
lists parts in alpha-numerical order of their hp stock
number and provides the following information on
each part;
a. Description of the part (see list of abbreviations
below).
b. Typical manufacturer of the part in a five-digit
code; see list of manufacturers in Table 6-3.
c. Manufacturer's part number.
d. Total quantity used in the instrument (TQ column).
6-3.
Miscellaneous parts are listed at the end of
Table 6-1.
6-4. ORDERING INFORMATION
6-5.
To obtain replacement parts, address order or
inquiry to your local Hewlett-Packard Field Office
(see lists at rear of this manual for addresses).
Identify parts by their Hewlett- Packard stock numbers.
6-6.
To obtain a part that is not listed, include;
a. Instrument model number.
b. Instrument serial number.
c. Description of the part.
d. Function and location of the part.
A
= assembly
B
=
motor
BT
=
battery
C
=
capacitor
CP
= coupler
CR
= diode
DL
= delay line
DS
= device signaling (lamp)
A
** amperes
A. F. C. = automatic frequency control
AMPL
=
amplifier
B. F. O. = beat frequency oscillator
BE CU
= beryllium copper
BH
=
binder head
BP
=
bandpass
BRS
=
brass
BWO
= backward wave oscillator
CCW
=
counter-ciockwise
CER
=
ceramic
CMO
= cabinet mount only
COEF
= coefficient
COM
= common
COMP
=
composition
CONN
=
connector
CP
= cadmium plate
CRT
= cathode-ray tube
CW
= clockwise
DEPC
= deposited carbon
DR
= drive
ELECT = electrolytic
ENCAP = encapsulated
EXT
= external
F
-• farads
FH
= flat head
FIL H
= fillister head
FXD
= fixed
REFERENCE DESIGNATORS
E
=
mise electronic part
MP
mechanical part
TB
_
terminal board
F
fuse
P
plug
TP
test point
FL
"
filter
Q
transistor
V
=
vacuum, tube, neoi
J
=
jack
R
resistor
bulb, photocell, etc
K
-
relay
RT
thermistor
W
cable
L
-•
inductor
S
switch
X
=
socket
M
meter
T
transformer
Y
*
crystal
ABBREVIATIONS
GE
germanium
N/C
normally closed
RMO
=
rack mount only
GL
=
glass
NE
neon
RMS
root-mean square
GRD
=
ground(ed)
NI PL
=
nickel plate
RWV
a
reverse working
N/O
normally open
voltage
H
= henries
NPO
negative positive zero
S-B
=
slow-blow
HEX
=
hexagonal
(zero temperature
SCR
-
screw
HG
=
mercury
coefficient)
SE
=
selenium
HR
-
hour(s)
NRFR
=
not recommended for
SECT
=
section(s)
field replacement
SEMI CON =
semiconductor
IF
a
iniermediate freq
NSR
not separately
SI
=
silicon
IMPG
impregnated
replaceable
SIL
=
silver
INCD
incandescent
3L
=
slide
IN CL
=
tncluae(s)
OBD
order by description
SPL
=
special
INS
=
insulation(ed)
OH
oval head
SST
=
stainless steel
INT
internal
OX
oxide
SR
=
split ring
STL
=
steel
K
kilo = 1000
P
peak
PC
printed circuit
TA
=
tantalum
LIN
=
linear taper
PF
picofarads = 10"^2
TD
=
time delay
LK WASH
-
lock washer
farads
TGL
=
toggle
LOG
*
logarithmic taper
PH BR2 =
phosphor bronze
TI
=
titanium
LPF
=
low pass filter
PHL
=
Phillips
TOL
=
tolerance
prv
peak inverse voltage
TRIM
=
trimmer
P/O
part of
TWT
=
traveling wave tube
M
=
milli - lO'-5
POLY
=
polystyrene
MEG
=
meg = 106
PORC
=
porcelain
U
=
micro = 10 0
MET FLM =
metal film
POS
position(s)
VAR
=
variable
MET OX
=
metallic oxide
POT
potentiometer
VDCW
=
dc working volts
MFR
=
manufacturer
PP
peak-to-peak
MINAT
=
miniature
PT
point
w/
=
with
MOM
=
momentary
PWV
peak working voltage
w
=
watts
MTG
=
mounting
SECT
=
rectifier
WTV
=
working inverse
MY
=
"mylar"
RF
radio frequency
voltage
,
-9,
RH
round head
WW
=
wi rewound
N
=
nano (10
)
RIV
reverse inverse voltage
W/O
=
without
01194-11
02152-1
6-1

Advertisement