Meter Coupling Lever
@
is lever couples with the lens' meter coupling ridge
®
on the aperture ring to perform full-aperture meter-
ing.
Lenses whose aperture ring doesn 't couple with
this lever can not be
used.
For the following lenses,
stop-down exposure measurement must be per-
formed.
For lenses or accessories without automatic
diaphragms
When a PC-Nikkor lens or bellows attachment is
used,
focusing should be done with the lens wide
open while exposure measurement and shooting
must be done with the lens stopped down
.
With
a
PC-Nikkor,
the correct exposure must be determined
on
manual before
shifting
the
lens.
For fixed-aperture
lenses,
photomicro-
graphy,
or astrophotography
Since the aperture
is
fixed when using Reflex-Nikkor
lenses, or in photomicrography or telescopic photog-
raphy, it is impossible to change the exposure by
varying the aperture. So, on auto, take the shot by
simply depressing the shutter release button. On
manual
,
turn the shutter speed/mode
selector
dial
until the correct exposure is obtained. If the
scene
is
too bright to obtain correct
exposure,
use an NO filter.