Changing/Inspecting The Avr - DuroStar XP12000E Service Manual

Table of Contents

Advertisement

TROUBLESHOOTING (CONTINUED)

Changing/Inspecting the AVR

36
The carbon brushes in conjunction with the AVR regulates
power from the generator. If the generator is overheated
or overloaded, the AVR may be damaged and require
replacement.
1.
Remove generator cover
Remove the 2 bolts of the generator cover then pull the cover
off the generator.
2.
Remove AVR bolts
Remove the 2 bolts holding the AVR.
3.
Disconnect AVR wire clip
Disconnect the wire clip.

Advertisement

Table of Contents
loading

Table of Contents