OmniOn Power G391 Quick Start Manual

Edge ac short circuit current limiter

Advertisement

Quick Links

QUICK START GUIDE
EDGE AC SHORT CIRCUIT CURRENT LIMITER
G391 – 1600481709A
SAVE THESE INSTRUCTIONS – This document contains
important safety and installation instructions for the
Edge Cabinet input current limiter accessory
Equipment is intended for installation only in restricted
access areas.
Rules and Regulations – Follow all national and local
rules and regulations when making field connections.
This equipment is not suitable for use in locations
where children are likely to be present.
Document - 8600481912P
Page 1
© 2023 OmniOn Power Inc. All rights reserved.
SAUVEGARDEZ CES INSTRUCTIONS – Ce document
contient des instructions de sécurité et d'utilisation
importantes pour l'accessoire limiteur de courant
d'entrée Edge Cabinet
L'équipement est destiné à être installé uniquement
dans des zones à accès restreint.
Règles et règlements – Suivez toutes les règles et
réglementations nationales et locales lorsque vous
établissez des connexions sur le terrain.
Cet équipement ne convient pas à une utilisation dans
des endroits où des enfants sont susceptibles d'être
présents.
Edge current limiter G391_QSG
Rev. 2.1

Advertisement

Table of Contents
loading

Summary of Contents for OmniOn Power G391

  • Page 1 Cet équipement ne convient pas à une utilisation dans des endroits où des enfants sont susceptibles d’être présents. Document - 8600481912P Page 1 © 2023 OmniOn Power Inc. All rights reserved. Edge current limiter G391_QSG Rev. 2.1...
  • Page 2: Table Of Contents

    Figure 9 Wire connections ................................10 Figure 10 Fuse blocks ..................................11 Figure 11 Clear removable panel ..............................11 Figure 12 Cabinet grounding ................................11 Page 2 © 2023 OmniOn Power Inc. All rights reserved. Edge current limiter G391_QSG Rev. 2.1...
  • Page 3: Important Safety Instructions

    à la barre omnibus de mise à la terre de l'armoire principale. Remarque : La mise à la terre correcte de l'alimentation CA doit être vérifiée par un personnel qualifié. • Ne placez pas de matériaux combustibles directement au-dessus ou en dessous de l'équipement. Page 3 © 2023 OmniOn Power Inc. All rights reserved. Edge current limiter G391_QSG Rev. 2.1...
  • Page 4: Precautions

    Personnel with electronic medical devices need to be aware that proximity to DC power and distribution systems, including batteries and cables, typically found in telecommunications utility rooms, can affect medical electronic devices, such as pacemakers. Effects decrease with distance. Page 4 © 2023 OmniOn Power Inc. All rights reserved. Edge current limiter G391_QSG Rev. 2.1...
  • Page 5 CC, y compris les batteries et les câbles, que l'on trouve généralement dans les locaux techniques de télécommunications, peut affecter les appareils électroniques médicaux, tels que les stimulateurs cardiaques. Les effets diminuent avec la distance. Page 5 © 2023 OmniOn Power Inc. All rights reserved. Edge current limiter G391_QSG Rev. 2.1...
  • Page 6: Safety

    The product ID label of the EDGECABG391 model is shown below. It includes the product serial number and input - output specifications of the cabinet. Figure 2 Product ID Label Information Customer Care +1 877 546-3243 Page 6 © 2023 OmniOn Power Inc. All rights reserved. Edge current limiter G391_QSG Rev. 2.1...
  • Page 7: Figure 3 Wiring Diagram

    Wiring diagram Figure 3 wiring diagram Page 7 © 2023 OmniOn Power Inc. All rights reserved. Edge current limiter G391_QSG Rev. 2.1...
  • Page 8: Information - Tools Required

    The top of the Edge cabinet is shown here. The relevant areas are noted: AC input panel which contains two twist-n-lock AC input receptacles for AC input power. Center back panel to be removed and replaced with Edge AC current limiter G391 assembly. Two AC input...
  • Page 9: Step 1. Disassemble Existing Ac Connections

    Remove the 4 screws on the back center panel and then remove the panel. Note: Both the AC input panel and the back center panel will be discarded. Figure 7 Central panel removed Page 9 © 2023 OmniOn Power Inc. All rights reserved. Edge current limiter G391_QSG Rev. 2.1...
  • Page 10: Step 3. Assemble Edgecabg391 To Cabinet

    Note: Cover is hidden in figure 8 and figure 9 to show the screw locations and wiring clearly. During assembly the cover does not need to be removed. Page 10 © 2023 OmniOn Power Inc. All rights reserved. Edge current limiter G391_QSG Rev. 2.1...
  • Page 11: Step 4. Final Assembly

    Attach clear, removable panel to the top cover. Torque to 10in-lb. Figure 11 Clear removable panel Connect ground wire provided in the G391 kit to the ground lug located on the bottom of the base panel assembly. Connect the other end of the ground wire to the cabinet ground bus.
  • Page 12 Description of the change 05-17-2023 Initial release Updated wiring diagram, Updated ordering 06-21-2023 code of fuses in “Check for deliveries” section 11-28-2023 Updated as per OmniOn template Page 12 © 2023 OmniOn Power Inc. All rights reserved. Edge current limiter G391_QSG Rev. 2.1...
  • Page 13 Any notice. OmniOn Power does not accept any responsibility reproduction, disclosure to third parties or utilization of for errors or lack of information in this document and its contents –...

This manual is also suitable for:

1600481709a