6 TECHNICAL SPECIFICATIONS
154 Series, multi-position models
RATING AND PERFORMANCE
Firing rate(USGPH)*
Input (BTU/h)*
Maximum Heating capacity, (BTU/h)*
Heating temperature rise (Degr. F)*
Flue draft with chimney (inch of w.c.)
Overfire pressure with chimney (inch of w.c.)
Flue pressure with direct vent (inch of w.c. - no wind)
Overfire pressure with direct vent (inch of w.c. - no wind)
BECKETT BURNER; NX MODEL (Chimney or DV)
Burner tube insertion length (inches)
Head type
Nozzle (Delavan)
Pump pressure (PSIG)*
Head/Air setting
AFUE % (From CSA B212 standard and Canadian regulation)**
AFUE % (From ASHRAE 103 standard and US regulation)**
RIELLO BURNER; 40-F5 MODEL (Chimney)
Burner tube insertion length (inches)
Nozzle (Delavan)
Pump pressure (PSIG)*
Combustion air adjustment (turbulator/damper)
AFUE % (From CSA B212 standard and Canadian regulation**
AFUE % (From ASHRAE 103 standard and US regulation)**
RIELLO BURNER; 40-BF5 MODEL (Direct vent DV)
Burner tube insertion length (inches)
Nozzle (Delavan)
Pump pressure (PSIG)*
Combustion air adjustment (turbulator/damper)
AFUE % (From CSA B212 standard and Canadian regulation)**
AFUE % (From ASHRAE 103 standard and US regulation)**
ELECTRICAL SYSTEM
Volts - Hertz - Phase
Rated current (Amps)
Minimum ampacity for wire sizing (Amps)
Max. fuse size (Amps)
Control transformer(VA)
External control power available: Heating (VA)
External control power available: Cooling (VA)
BLOWER DATA
Heating blower speed at 0.25" W.C. SP
Heating blower speed at 0.50" W.C. SP
Motor (HP) / number of speeds
Blower size (diam. x width)
GENERAL INFORMATION
Overall dimensions (width x depth x height)
Supply air opening (width x depth)
Return air opening (width x depth)
Filter size
Shipping weight Lbs/Kg
Air conditioning, maximum output (tons) at 0.5" W.C. SP
Table 6 – Technical specifications
* INPUT AND OUTPUT ADJUSTMENT :
- Pump pressure can be adjusted to maintan proper firing rate
- Increase pump pressure if flue gases' temperature is under 400°F
- Adjust the total flue gas temperature between 400°F and 575 °F (330°and 505°F net approx.)
- Adjust fan speed for air temperature rise to be in specified range
** AFUE value established after minimum 20 hours of operation.
UNITS WITH 1.0 HP 4-SP. MOTOR
0.90
1.10
126,000
154,000
107,000
129,000
55 - 75 Degr. F
-0.06 to -0.035
-0.035 to +0.045
+0.05 to +0.16
+0.06 to +0.22
NX50LC
1 3/4"
6 Slots - LC head
0.75 - 60B
0.90 - 60B
145
150
3,5
4
87.0%
85.6%
85.3%
85.1%
F5 WITH ELECTRIC AIR DAMPER
2 3/4"
0.75 - 70A
0.90 - 70A
145
150
1.5 / 2.25
2.5 / 2.75
86.6%
85.3%
86.0%
85.0%
BF5
2 3/4"
0.75 - 70A
0.90 - 70A
145
150
1.0 / 3.75
3.0 / 4.25
86.4%
85.7%
86.1%
85.0%
115 - 60 - 1
16,9
19,5
20
40
40
30
MED-LOW
MED-HIGH
MED-LOW
MED-HIGH
1.0 HP / 4 speeds
12" x 10" (tight housing)
25" x 28 1/2" x 48"
20" x 22"
23" x 23"
24" x 24" x 1"
200 / 90
5.0
13
UNITS WITH 1.0 HP ECM MOTOR
0.90
126,000
107,000
60 - 72 Degr. F
-0.06 to -0.035
-0.035 to +0.045
+0.05 to +0.16
+0.06 to +0.22
NX50LC
1 3/4"
6 Slots - LC head
0.75 - 60B
145
3,5
‡ 87.0%
‡ 85.3%
F5 WITH ELECTRIC AIR DAMPER
2 3/4"
0.75 - 70A
145
1.5 / 2.25
‡ 86.6%
‡ 86.0%
BF5
2 3/4"
0.75 - 70A
145
1.0 / 3.75
‡ 86.4%
‡ 86.1%
115 - 60 - 1
15,7
18,1
20
40
40
30
See the ECM air flow table
1.0 HP / ECM (with inductor)
12" x 10" (tight housing)
25" x 28 1/2" x 48"
20" x 22"
23" x 23"
24" x 24" x 1"
200 / 90
5.0
‡=
1.10
154,000
129,000
0.90 - 60B
150
4
‡ 85.6%
‡ 85.1%
0.90 - 70A
150
2.5 / 2.75
‡ 85.3%
‡ 85.0%
0.90 - 70A
150
3.0 / 4.25
‡ 85.7%
‡ 85.0%