Model:
EMP-W207A7-0024-207
EMP-W207A7-0024-257
Instruction Manual
DMC Co. Ltd.
https://www.dush.co.jp/english/
- 1 -
20A4A4-00002E-1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EMP Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for DMC EMP Series

  • Page 1 EMP Series Teaching Pendant With Linux Embedded Touchscreen Model: EMP-W207A7-0024-207 EMP-W207A7-0024-257 Instruction Manual DMC Co. Ltd. https://www.dush.co.jp/english/ - 1 - 20A4A4-00002E-1...
  • Page 2: Table Of Contents

    Table of Contents Introduction ..................3 Notes ..................3 Precautions for Safe Use ................. 3 Warnings ..................4 Cautions ..................5 Handling of LCD Panels ................ 7 Handling of Touchscreens ..............7 Packaged Contents ................8 Name of Parts ................... 9 External Interface ................
  • Page 3: Introduction

    ◼ DMC shall not be held liable in any way for damages or losses, nor be held responsible for any claims by a third party as a result of using this product.
  • Page 4: Warnings

    Warnings Warning! Warnings for Design Designing switches that might cause human injuries and/or property damages on the touchscreen is strictly prohibited. Unintentional output signals due to malfunction of the main body, units, and/or cables, etc. can cause serious injuries. Please design the system so that switches with major functions are equipped on device other than the EMP.
  • Page 5: Cautions

    Warnings for Wiring For wiring and installation, please refer to the manual and specifications in order to conduct it correctly. Failure to do so may cause fires and/or electric shocks. Before installing the power cable, make sure power is not being supplied from power source. Failure to do so may cause electrical shocks.
  • Page 6 To Avoid Malfunctions Do not press down hard on the display area of the EMP with hard objects. Doing so may break the touchscreen LCD panel and may cause injuries. Also, do not press down on the panel with sharp objects such as mechanical pencils and drivers.
  • Page 7: Handling Of Lcd Panels

    Handling of LCD Panels 1) The LCD contains skin-irritating materials. If liquid materials flow or spill out due to damages and comes in contact with the skin, immediately wash the area under running water for at least 15 minutes and consult a physician. 2) The LCD might have uneven brightness according to the contents being displayed.
  • Page 8: Packaged Contents

    *Maximum number of units that could be stored: 1unit <Note> Although all efforts have been made to ensure the quality and packaging at shipment, should you notice any damage or shortage of parts, please contact your dealer or DMC for additional instructions before use. - 8 - 20A4A4-00002E-1...
  • Page 9: Name Of Parts

    Name of Parts 7W TFT Touchscreen Name Contents Hole for hooks to hang on walls* Bracket for temporarily hanging the EMP on walls Emergency Stop Switch Emergency Stop Switch Contact Output ・Device side output Form B contact x 2 ・Internal use * Form B contact ×...
  • Page 10: External Interface

    External Interface Power/ Communication/ Contact Output I/F Round Connector: HR22-12WTRA-20pc (73) (by HRS) Contact: Gold plated Signal Remarks LAN_RXD+ Ethernet LAN_RXD- LAN_TXD+ LAN_TXD- Not connected S_NC1 Selector contact 1 (Form B contact) S_C1 S_NC2 Selector contact 2 (Form B contact) S_C2 Not connected A_NC1...
  • Page 11: Emergency Stop Switch Output

    Contact Signal Details Emergency Stop Form B contact A_NC1 Contact 1 Contact rating: 1A/DC30V (Resistive load), 1A/DC30V (Inductive load) A_C1 (Reference value Minimum applicable load DC5V 1mA) Emergency Stop Form B contact A_NC2 Contact 2 1A/DC30V (Resistive load), 1A/DC30V (Inductive load) A_C2 (Reference value Minimum applicable load DC5V 1mA) Activating the emergency stop switch will contact output.
  • Page 12: Enable Switch Output

    Contact Signal Details Enable Contact 1 Form A contact [3 position] E_NC1 Contact rating: 1A/DC30V (Resistive load), 0.7A/DC30V (Inductive load) E_C1 (Reference value Minimum applicable load DC5V 1mA) Enable Contact 2 Form A contact [3 Position] E_NC2 Contact rating: 1A/DC30V (Resistive load), 0.7A/DC30V (Inductive load) E_C2 (Reference value Minimum applicable load DC5V 1mA)
  • Page 13: Selector Switch Output

    Contact Signal Details Selector Contact 1 S_NC1 Form B contact Contact rating: 1A/DC30V (Resistive load), 0.7A/DC30V S_C1 (Inductive load) (Reference value Minimum applicable load DC5V 1mA) Selector Contact 2 S_NC2 Form B contact Contact rating: 1A/DC30V (Resistive load), 0.7A/DC30V S_C2 (Inductive load) (Reference value Minimum applicable load DC5V 1mA) Switching the selector switch will contact output.
  • Page 14: Wiring

    Wiring EMP Connection Connecting with external interface. ・Compatible connector: HR22-12WTPA-20SC (by HRS) (Contact: gold plated) *Option cable ‘SWHC-F1-001’ can be used. External Interface SWHC-F1-001 ・When inserting and removing the connector, be sure to turn off the power of the circuit. ・Be sure to engage the screw lock mechanism when using the connector (Tighten the screw securely and completely).
  • Page 15: Calibration

    Calibration Touchscreen Coordinate Calibration If there is a large misalignment between the pressed location and the detected coordination, please conduct calibration. - 15 - 20A4A4-00002E-1...
  • Page 16: Boot-Up

    Boot-up Make sure the power wiring is complete before turning the power ON. After the startup screen appears, the OS will start up. Maintenance Display When the surface or the frame of the display gets dirty, wipe with a soft cloth damped in diluted neutral detergent and wrung tightly.
  • Page 17: Optional Items

    Optional Items ■Development Kit Model Specifications (Configuration) SWDK-103 1 Conversion board with composite cable terminal block 1 set of IS-APP Development Environment ■Option Cable Model Specifications (Configuration) SWHC-F1-001 1 Cable (length: 5m) Separated wire on HOST connection side (with semi-stripped tip) - 17 - 20A4A4-00002E-1...
  • Page 18: Warranty And Repairs

    (1) Only DMC products can be repaired. Options are exempt. (2) Programs and data might be lost during repair. Please be sure to take back-up in advance. DMC will not be held liable for programs or data lost during repair.
  • Page 19: Others

    URL: https: //www.dush.co.jp/english/ This product and document are protected by the copyright law. Photocopying, duplicating, reproducing, and modifying of this product or document in part or by whole is prohibited. Copyright(C) 2023 DMC Co., Ltd. All Rights Reserved - 19 - 20A4A4-00002E-1...