Download Print this page

Invacare 5143B Service Manual

84 inch bed extension

Advertisement

Quick Links

Service Manual
DEALER: Keep this manual. The procedures in this manual MUST
be performed by a qualified technician.
84 inch Bed Extension (5143B)
1 General
Check all parts for shipping damage. In case of damage, DO NOT use. Contact Carrier/Invacare for
further instructions.
To ensure the safe installation of the crossover cable service kit, these instructions must be followed:
1.1
Symbols
Signal words are used in this manual and apply to hazards or unsafe practices which could result in
personal injury or property damage. See the information below for definitions of the signal words.
WARNING
Warning indicates a potentially hazardous situation which, if not avoided, could
result in death or serious injury.
CAUTION
Caution indicates a potentially hazardous situation which, if not avoided, may result
in property damage or minor injury or both.
Gives useful tips, recommendations and information for efficient, trouble-free use.
1.2
Tools Required:
Two 1/2 inch open end wrenches; one vice grip
1.3
Kit includes the following:
7000M465 Extension Weldment L.H., Qty 1; 7000M466 Extension Weldment R.H., Qty 1
7000M469 Pull Tube End Assembly (5143/5143IVC), Qty 1
553000M699 Link Fabric Extension with Open Hooks Attached, Qty 2
53000M701Instruction Sheet, Qty 1
53000M434 Bi-way Locknut, Qty 2
54000M6412 5/16-18 x 1-inch Bolt, Qty 2
51000M135 Helical Spring, Qty 4
1176192 Bed Extender Sub Assembly, Qty 1
Part No 53000M701
1
Get other manuals https://www.bkmanuals.com
84 inch Bed Extension (5143B)

Advertisement

loading

Summary of Contents for Invacare 5143B

  • Page 1 84 inch Bed Extension (5143B) 1 General Check all parts for shipping damage. In case of damage, DO NOT use. Contact Carrier/Invacare for further instructions. To ensure the safe installation of the crossover cable service kit, these instructions must be followed:...
  • Page 2: Intended Use

    Invacare products are specifically designed and manufactured for use in conjunction with Invacare accessories. Accessories designed by other manufacturers have not been tested by Invacare and are not recommended for use with Invacare products. After any adjustments, repair or service and before use, make sure all attaching hardware is tightened securely - otherwise injury or damage may result.
  • Page 3 Attach one helical spring (F) to one end of the link fabric extension (D). Attach the opposite end of the helical spring (F) to one of the four mounting holes in the four-inch extension (A). Part No 53000M701 84 inch Bed Extension (5143B) Get other manuals https://www.bkmanuals.com...
  • Page 4 Attach bed ends to head and foot spring assemblies. 10. Using the existing drive shaft (K), slide the bed extender sub-assembly (L) on either end and attach drive shaft to head and foot boards. 84 inch Bed Extension (5143B) Part No 53000M701 Get other manuals https://www.bkmanuals.com...
  • Page 5: Assembled View

    13. Reconnect pull tube (E) to head spring drive arm using the clevis (G) and cotter (F) pins.  Bed requires an 84-inch mattress. If assistance is required or any problems are encountered during the conversion, contact customer service at 1-800-333-6900 Part No 53000M701 84 inch Bed Extension (5143B) Get other manuals https://www.bkmanuals.com...
  • Page 6 NOTES 84 inch Bed Extension (5143B) Part No 53000M701 Get other manuals https://www.bkmanuals.com...
  • Page 7 NOTES Part No 53000M701 84 inch Bed Extension (5143B) Get other manuals https://www.bkmanuals.com...
  • Page 8 Invacare Corporation © 2011 Invacare Corporation. All rights One Invacare Way reserved. Republication, duplication or Elyria, Ohio USA modification in whole or in part is 44036-2125 prohibited without prior written 440-329-6000 permission from Invacare. Trademarks are 800-333-6900 identified by ™ and ®. All trademarks are...