Download Print this page

Universal Innovations PROVENCE User Manual page 2

Flueless gas stove

Advertisement

If you require any further assistance please do not hesitate to contact us directly at the factory.
Test all gas connections for leaks with proprietary leak detection fluid or
soapy water applied with a small paintbrush.
Fit the back panel of the heater by positioning the tabs on the bottom of
the door into the inside of the rim at the bottom of the heater. Then push
the panel flush with the back of the heater and rotate the door catch to the
up position to secure the panel.
An odour at first use is normal. Burn on highest setting in a very well ventilated area for 4 hours to cure synthetic logs.
TECHNICAL & SERVICING INFORMATION
Technical and servicing information:
This appliance is designed for indoor use only, using Butane gas at a supply pressure of 28-
30 millibar and must be serviced by a fully quali ed and competent registered engineer in
accordance with the instructions included.
Please read all accompanying documentation carefully.
Technical Specifi cations:
Overall height:
775 millimetres approximately
Overall width:
460 millimetres approximately
Heat input:
3.4kW (Gross)
Gas consumption:
245 grams per hour at maximum setting
Gas category:
I3B using Butane gas at 28-30mbar
Gas type & Supply pressure: Butane 28-30 mbar
Injector size:
0.9 mm
Cylinder sizes:
11.34kg cylinder (Eire) and 15kg or 7kg cylinder (U.K)
Hose:
Length 40 cm LPG hose compliant to EN 16436-1
Destination Countries:
IE/GB
The product is fully guaranteed for two years regarding proper use.
This guarantee does not a ect your statutory rights. For servicing contact your local gas
supplier. Servicing to be carried out by a quali ed, competent registered gas engineer before
the start of every heating season.
For help on this product and our range of products see our website www.saharabbqs.com or
contact the factory direct on our Helpline 00 353 1 2873797.
Helpline hours are 9am to 5pm Monday to Friday.
We are located at: Universal Innovations Ltd.
Kilcoole Industrial Estate,
Kilcoole,
Co. Wicklow,
Ireland.
ASSEMBLY INSTRUCTIONS - IN 3 EASY STEPS
HELPLINE DUBLIN IRELAND: Ph: 00 353 1 2873797, Email: info@saharabbqs.com
Remove the box containing synthetic logs and cardboard
2797/23
Box containing
sythetic logs
Cardboard Insert
Open the heater door by loosening the thumb screw.
insert from the heater.
Carefully remove the synthetic logs from the box.
Do not:
Attempt to use the heater in high rise flats, basements, bathrooms or bedrooms.
Do not:
Use any other gas except Butane.
Do not:
Attempt to clean the heater until it is turned off and fully cooled.
Do not:
Use naked flame to detect suspected gas leaks.
Do not:
Allow children or pets to play near the heater.
Do not:
Twist the flexible gas hose.
Do not:
Touch the glass panel or front and sides of the unit while the heater is operating. Allow the
unit to cool down for one hour before touching the front or sides.
Do not:
Use in leisure vehicles such as caravans and autocaravans.
Do not:
Position the appliance close to walls, furniture, hangings, net curtains, bed linen and other
inflammable materials as this would result in the risk of fire.
In the event of a gas leak. ie. If you smell gas, turn off the cylinder valve. Disconnect the cylinder, take
it outdoors and contact a competent service technician.
Warning:
Never attempt to light the unit if the hose is loose or damaged in any way. Also never attempt to light
the unit if you have reason to believe that the unit may be leaking gas. In the event of a gas leak turn
off the gas supply at the cylinder and have the unit fully checked by a competent person in accordance
with the instructions enclosed. We recommend servicing at the start of every heating season.
Should you need to change the gas bottle, confirm that the gas supply is turned off at the cylinder and
that there are no sources of ignition near before proceeding.
Do:
Place heater on a flat, level and solid surface at all times.
Do:
Leak test the unit after long periods of storage.
Do:
Wait for 3 minutes before relighting, if the burner flame becomes extinguished during use.
Do:
Ensure that all naked flames are extinguished before fitting a new cylinder.
Do:
Store gas cylinders outdoor, above ground level in a safe and secure environment.
Do:
Make sure that the gas supply at the gas cylinder is turned off after use.
Do:
Ensure that servicing of the unit is carried out by a competent person in accordance with the
instructions enclosed.
Do:
Allow the unit to cool down for one hour before touching the front or sides.
Always:
Follow any safety instructions supplied with gas cylinders.
Always:
Keep unit well away from glass doors and windows to ensure no possibility of heat build up
and damage.
Always:
Service once a year or after a prolonged period of non-use.
Always:
Ensure that there is no blockage of airflow. For example sooting and poor burning can be
caused by dirt, insects, cobwebs, blocking the airflow to/in the burner.
Cleaning:
Abrasive cleaners are not to be used. Clean unit with a damp cloth when fully cooled.
Gas Cylinders:
This unit is designed for use with a 7kg or 15kg (UK) and 11.4kg Butane gas cylinder (Eire).
For help, contact our website www.saharabbqs.com or our factory helpline.
Helpline hours: 9am - 5pm Monday to Friday. Ph: 00 353 1 2873797.
Place the synthetic logs into the heater grate as shown.
Close door and lock with thumb screw. To fit battery,
unscrew ignition button and place battery
inside housing. Refit ignition button securely.
(place battery "+" side up)
SAFETY INSTRUCTIONS
Do Not Bring Goods Back To Place Of Purchase.

Advertisement