Advertisement

Quick Links

HID® Mercury™ MR16out-S3 Processor Installation and Specifications
HID® Mercury™ MR16out-S3 Processor
Installation and Specifications
PLT-05251, A.2
August 2022

Advertisement

Table of Contents
loading

Summary of Contents for HID Mercury MR16out-S3

  • Page 1 HID® Mercury™ MR16out-S3 Processor Installation and Specifications HID® Mercury™ MR16out-S3 Processor Installation and Specifications PLT-05251, A.2 August 2022...
  • Page 2: What's New

    Trademarks HID GLOBAL, HID, the HID Brick logo, and HID Mercury are trademarks or registered trademarks of HID Global, ASSA ABLOY AB, or its affiliate(s) in the US and other countries and may not be used without permission. All other trademarks, service marks, and product or service names are trademarks or registered trademarks of their respective owners.
  • Page 3 Section 01 Overview...
  • Page 4 Powering HID® Mercury™ MR16out-S3 Processor Trusted Identities Installation and Specifications 1.1 MR16out processor The MR16out processor provides a solution to the OEM system integrator for output control. The controller has 16 Form-C contact relays for load switching. Additionally, two digital inputs are provided for tamper and power fault status monitoring.
  • Page 5 Section 02 MR16out wiring and setup...
  • Page 6: Communication Wiring

    Powering HID® Mercury™ MR16out-S3 Processor Trusted Identities Installation and Specifications 2.1 Supplying power to the MR16out The MR16out requires 12 to 24 V DC for power on TB11. Locate power source as close to the unit as possible. Connect power with minimum of 18 AWG wires.
  • Page 7: Relay Outputs

    Powering HID® Mercury™ MR16out-S3 Processor Trusted Identities Installation and Specifications 2.3 Inputs for cabinet tamper/power fault Input CT and input BA are used for monitoring cabinet tamper and power failure with normally closed contacts. These two inputs are for contact closure monitoring only, and do not use EOL resistor(s). If these inputs are not used, install a short piece of wire at the input to indicate a safe condition.
  • Page 8 Powering HID® Mercury™ MR16out-S3 Processor Trusted Identities Installation and Specifications 2.5 DIP switch and jumper usage Switches 1 to 5 select the device address. Switch 6 and 7 select the communication baud rate. Switch 8 enables encrypted communication. All other configuration settings are set via host software.
  • Page 9 Powering HID® Mercury™ MR16out-S3 Processor Trusted Identities Installation and Specifications Selection Address 30 Address 31 115,200 BPS 9,600 BPS 19,200 BPS 38,400 BPS Encrypted communication not required Encrypted communication required 1. Firmware revisions prior to 1.30.1, this setting is 2,400 BPS.
  • Page 10: Status Leds

    Powering HID® Mercury™ MR16out-S3 Processor Trusted Identities Installation and Specifications 2.6 Status LEDs 2.6.1 Power-up All LEDs are OFF. 2.6.2 Initialization Once power is applied, initialization of the module begins. When initialization is completed, LEDs A, B, CT, and BA are briefly sequenced ON then OFF.
  • Page 11 Section 03 Specifications...
  • Page 12 Powering HID® Mercury™ MR16out-S3 Processor Trusted Identities Installation and Specifications Revision D assembly: The MR16out is for use in low voltage, class 2 circuits only. Primary power 12 to 24 V DC ± 10%, 1100 mA maximum Relay contacts Normally open contact (NO) contact: 5 A @ 30 V DC resistive...
  • Page 13: Warranty

    Powering HID® Mercury™ MR16out-S3 Processor Trusted Identities Installation and Specifications 3.1 Warranty Mercury Security warrants the product is free from defects in material and workmanship under normal use and service with proper maintenance for one year from the date of factory shipment. Mercury Security assumes no responsibility for products damaged by improper handling or installation.
  • Page 14: Revision History

    Powering HID® Mercury™ MR16out-S3 Processor Trusted Identities Installation and Specifications Revision history Date Description Revision August 2022 New branding. March 2021 Minor update. October 2020 Initial release. PLT-05251, A.2 August 2022...
  • Page 15 For technical support, please visit: https://support.hidglobal.com © 2022 HID Global Corporation/ASSA ABLOY AB. All rights reserved. PLT-05251, Rev. A.2 Part of ASSA ABLOY Dummy text.

Table of Contents