  • Page 1 Metal Work FluxUp MANUALE D’USO Metal Work FluxUp USER MANUAL...
  • Page 2: Installazione

    L’APP Metal Work FluxUp, consente il collegamento via Bluetooth, da smartphone Android e IOS, ai flussimetri Metal Work della serie FLUX 1 e 2, dotati di interfaccia wireless. Tramite Metal Work FluxUp è possibile visualizzare in tempo reale, tutti i dati rilevati da FLUX ed impostare i tutti parametri di funzionamento.
  • Page 3 2.2 UTILIZZO Avviare l’App, al primo avvio effettuare la scansione dei dispositivi, successivamente ad ogni avvio l’APP tenterà di ricollegarsi all’ultimo dispositivo connesso. Se il dispositivo è disponibile, in caso di errore, è necessario premere il pulsante Riprova per riprovare a collegarsi. Per effettuare una nuova scansione, aprire il menù...
  • Page 4 2.3 DASHBOARD Nella pagina Dashboard vengono visualizzati in tempo reale i dati delle misurazioni. Le unità di misura sono impostabili nel menù Impostazioni, indipendentemente da quelle impostate su FLUX. La barra superiore visualizza il nome del dispositivo a cui si è collegati. La barra inferiore visualizza il menu delle funzioni.
  • Page 5 2.5 GRAFICI La pagina Grafici visualizza i grafici dei valori salvati di portata e pressione. Ad ogni connessione vengono richiesti i dati di pressione e portata salvati da FLUX. Per aggiornare il grafico cliccare sul pulsante Ricarica. É possibile selezionare il tempo di visualizzazione del grafico. La visualizzazione è...
  • Page 6 2.6.1 IMPIANTO Consente di impostare il tipo di Gas utilizzato e il coefficiente per il calcolo dell’energia consumata. 2.6.2 I/O Consente di impostare i parametri di funzionamento dell’ingresso digitale e dell’uscita digitale. Versione IO-Link...
  • Page 7 Versione analogica 2.6.3 DISPLAY Consente di impostare: - l’orientamento del Display; - la lingua; - l’unità di misura della portata; - l’unità di misura della pressione; - i valori di cambio colore della visualizzazione della portata.
  • Page 8 2.6.4 WIRELESS Consente di impostare i parametri di connessione alla rete wireless: - Abilita con selezione del server. Per il server METALWORK i parametri sono già impostati. Per il server Custom è necessaria l’impostazione dei seguenti parametri: SSID IP address MQTT 2.6.4.1 SSID - Nome: inserire il nome della rete alla quale collegarsi...
  • Page 9 2.6.4.2 IP - DHCP: l’indirizzo IP viene assegnato dal server DHCP - STATICO: l’indirizzo IP viene assegnato permanentemente Indirizzo IP, impostare l’indirizzo IP del dispositivo nella stessa classe di rete del Gateway di collegamento. Indirizzo, impostare la maschera in funzione dell’intervallo di indirizzi IP all’interno della sottorete.
  • Page 10 2.6.4.4 INFO - MAC WIR: MAC address per il protocollo Wireless - MAC BLU: MAC address per la connessione via FluxUp - SW VER: versione software del software di comunicazione radio - Locazione: impostare il nome del dispositivo, sono consentiti 11 caratteri.
  • Page 11 2.6.6 SERVIZIO Cliccando sul pulsante Azzera consumi, i valori memorizzati di Volume, Energia e Massa vengono azzerati. Cliccando sul pulsante Azzera grafici, i grafici vengono resettati. 2.7 INFO La pagina Info visualizza le informazioni del dispositivo: - lo stato della rete, i parametri della rete (indirizzo IP, GATEWAY, DNS1, DNS2); - la versione del firmware;...
  • Page 12: Collegamento Wireless

    STRUTTURA DEL COLLEGAMENTO CON GATEWAY METAL WORK Il Gateway Metal Work si occupa della raccolta dati, della formattazione e dell’analisi, presentandoli in una pagina Web visualizzabile tramite browser. I dati sono residenti e archiviati nel Gateway, quindi sempre visualizzabili da qualsiasi utente accreditato.
  • Page 13 CARATTERISTICHE DELLA CONNESSIONE WIRELESS Gateway SSID_SECURITY nessuna o WPA/WPA2/WPA3 SSID_NAME max 31 caratteri SSID_KEY max 62 caratteri IP statico / dhcp Broker MQTT ENCRYPTION nessuna, TLS 1.0, 1.1, 1.2 (require_certificate = false) BROKER IP ADDRESS BROKER IP PORT 1883,8883 Autenticazione utente (opzionale): AUTH_NAME max 8 caratteri AUTH_KEY max 8 caratteri Struttura dei dati in formato MQTT (struttura pacchetti dati JSON)
  • Page 14 Esempio Dashboard...
  • Page 15 4. CERTIFICAZIONI Questo dispositivo contiene: FCC ID: XPYNINAW106 IC: 8595A-NINAW106 Il modulo serie NINA-W15 è certificato nei seguenti Paesi/regioni: • Europe (RED) • USA (FCC) • Canada (IC) • Japan (MIC) • Taiwan (NCC) • South Korea (KCC) • Brazil (ANATEL) •...
  • Page 16 NOTE...
  • Page 17 NOTE...
  • Page 18: Installation

    FLUX 1 and 2 series with a wireless interface, from Android smartphone and iOS. With the Metal Work FluxUp App, you can view all data recorded by the FLUX and set all operating parameters in real time.
  • Page 19: Operation

    2.2 OPERATION Run the App and scan the devices the first time it is started. Afterwards, each time it is started, the App will attempt to reconnect to the last connected device. If the device is available, in case of an error, press the Retry button to connect again. To rescan, open the top left menu and select ‘Devices’, All previously associated devices will be displayed.
  • Page 20 2.3 DASHBOARD The dashboard page displays measurement data in real time. The units of measurement can be entered in the Setting menu, irrespective of the units set on the FLUX. The top bar displays the name of the device being connected. The bottom bar displays the function menu.
  • Page 21 2.5 CHARTS The Charts page displays the graphs of saved flow rate and pressure values. Each time a connection is made, the pressure and flow rate data saved by the FLUX are requested. By clicking on the Reload button, the chart will be updated. The selection of the visualization time is possible.
  • Page 22 2.6.1 PLANT Used to set the type of gas used and the coefficient for calculating the energy consumed. 2.6.2 I/O Used to set the operating parameters of the digital input and output. IO-Link version...
  • Page 23 Analogue version 2.6.3 DISPLAY Can be used to set: - display orientation; - language; - flow rate measuring unit; - pressure measuring unit; - flow rate display colour change values.
  • Page 24 2.6.4 WIRELESS Can be used to set wireless network connection parameters: - Enable via server selection For the METALWORK server, the parameters are already set. For the Custom server, the following parameters must be set: SSID IP address MQTT 2.6.4.1 SSID - Name: enter the name of the network you wish to connect to - By clicking on the icon to the right of the Name field, the available networks are displayed...
  • Page 25 2.6.4.2 IP - DHCP: the IP address is assigned by the DHCP server - STATIC: the IP address is assigned permanently IP address, set the IP address of the device in the same network class as the link Gateway. Address mask, Set the mask according to the IP address range in the given subnetwork. IP DNS 1 and 2, Set the DNS server address, visible in the properties of the Wi-Fi network in use.
  • Page 26 2.6.4.4 INFO - MAC WIR: MAC address for the Wireless protocol - MAC BLU: MAC address for connection via the FluxUp - SW VER: software version of the radio communication software - Location: can be used to set the device name, 11 characters are allowed.
  • Page 27 2.6.6 SERVICE By clicking on the Reset consumption button, the stored values of Volume, Energy and Mass are reset to zero. By clicking on the Reset graphs button, the graphs are reset. 2.7 INFO The info page displays device information: - network status, network parameters (IP address, GATEWAY, DNS1, DNS2);...
  • Page 28: Wireless Connection

    LINK STRUCTURE WITH THE METAL WORK GATEWAY The Metal Work Gateway handles the collection, formatting and analysis of data, displaying them in a browser-viewable web page. The data is resident and stored in the Gateway, thus always viewable by any authorised user.
  • Page 29 WIRELESS CONNECTION FEATURES Gateway SSID_SECURITY nessuna o WPA/WPA2/WPA3 SSID_NAME max. 31 characters SSID_KEY max. 62 characters IP static / DHCP Broker MQTT ENCRYPTION none, TLS 1.0, 1.1, 1.2 (require certificate = false) BROKER IP ADDRESS BROKER IP PORT 1883,8883 User authentication (optional): AUTH_NAME max.
  • Page 30 Example: Dashboard...
  • Page 31: Qualification And Approvals

    4. QUALIFICATION AND APPROVALS This device contains FCC ID: XPYNINAW106 IC: 8595A-NINAW106 The NINA-W15 module series is certified for use in the following countries/regions: • Europe (RED) • USA (FCC) • Canada (IC) • Japan (MIC) • Taiwan (NCC) • South Korea (KCC) •...