OFG5311 Installation Guide V1.0.0 Internal Use Only Product Overview OFG5311tripod turnstile is designed for personnel access control. It can be used with face recognition devices to realize precise access control and supports multiple authentication modes including QR code, face, card, induction, keep open, etc. This product has a simple and elegant design, uses an advanced movement to ensure long-term reliability, and can be widely used in scenarios such as education, parks, and residential compounds.
OFG5311 Installation Guide V1.0.0 Internal Use Only Site Survey Before the site survey, you need to have a comprehensive understanding of the project, including background, scale, quality objectives, cycle, bidding documents, contracts, design plans and drawings. Then you can conduct a survey on site based on the above information, and combine the survey results with the customer’s needs to decide the exact installation location of the device.
OFG5311 Installation Guide V1.0.0 Internal Use Only Site Survey Report After the site survey is complete, you need to make a site survey schematic diagram, including environmental information (installation width, whether a shade, illuminator or logistics lane is required), installation location and direction. With this schematic diagram, you can determine the cable length/type and the number/type of devices required, estimate the number of technicians required, and produce a site survey report.
OFG5311 Installation Guide V1.0.0 Internal Use Only ESD wrist strap or gloves Marker Used to mark mounting holes. Tape measure Used to measure dimensions. Electric hammer drill (16mm drill bit is recommended) Used to drill holes. Hammer Used to hammer expansion screws into the ground.
OFG5311 Installation Guide V1.0.0 Internal Use Only Model Standard Width OFG5311 550mm 1. Install Power Cables Install power cables at the appropriate location according to the design layout of the device. See the table below for power cable specifications. Number of Lanes Power Cable Requirements RVV3*1.5...
OFG5311 Installation Guide V1.0.0 Internal Use Only Cable Wiring Requirements Mark and label the defined cables at both ends before wiring to facilitate future maintenance. Separate the signal cables and power cables to prevent interference from high voltage to signal transmission.
OFG5311 Installation Guide V1.0.0 Internal Use Only 3. Drill holes at the marked points and insert expansion bolts. 4. Align the mounting holes at the bottom of the pedestal with the expansion bolts on the ground, and then tighten the bolts to secure the pedestal.
OFG5311 Installation Guide V1.0.0 Internal Use Only 5.2.2 Control Board Wiring 5.2.3 Remote Control Wiring Take B53 remote control as an example: 1. Connect the 4P terminal to the receiver of the remote control and cut off the 5P terminal.
OFG5311 Installation Guide V1.0.0 Internal Use Only 5.2.4 Face Recognition Terminal Wiring Take ET-S33C as an example: Configuration Parameter Value Function Function Description Default Type Range If a person passes through the gate within Passing the set time, the time will be automatically...
Page 13
OFG5311 Installation Guide V1.0.0 Internal Use Only Used to detect continuous open signals. If the received open signal lasts longer than the set time, the gate will consider it a Keep continuous signal and keep open (F2 0s, keep open...
Need help?
Do you have a question about the OFG5311 and is the answer not in the manual?
Questions and answers