 The TX141-Bv2 remote sensor comes packaged with this atomic clock.
 The TX141-Av2 (433MHz) remote sensor is compatible with this atomic clock.

Quick Connect

Explanation: Use the quick connect for an atomic clock and remote sensor that
have been working but lost connection due to interference or low batteries. This is
not the same as a thorough factory reset.
1. Bring the remote sensor and atomic clock together inside and place the units 5-
10 feet apart with nothing between them.
2. Hold the MINUS button for 5 seconds. The remote temperature area will flash.
3. Remove battery cover from the remote sensor and press and release the TX
button to send the signal.
4. Wait for 2 minutes for the remote temperature to appear on the atomic clock.
Factory Restart:
reset.

Remote Temperature Signal Strength

Explanation: The atomic clock will search for the remote temperature remote
sensor for 3 minutes after batteries are installed or when the MINUS button is held
for 3 seconds.
 The antenna symbol will flash during reception.
 The temperature display will be dashes "---".
 If synchronization fails once, the antenna will lose one bar.
 If synchronization fails twice, the antenna will lose two bars.
 If RF (radio frequency) reception fails five times, the antenna symbol will show
without bars.
 The antenna will show a full display with successful RF (radio frequency)
reception.

Dashes show for Remote Temperature

Explanation: Dashes mean the connection is lost between the atomic clock and
the remote sensor.
Batteries
often resolve the connection.
Distance/Resistance
and the atomic clock.
 Turn the atomic clock 90 degrees towards the remote sensor to provide better
reception. This allows more antenna surface to face the remote sensor signal.
 Try the
quick connect

Power Requirements

 2-AA
batteries
power the remote sensor.
 2-AA
batteries
power the clock.
 We recommend Alkaline batteries for the remote sensor.
La Crosse Technology, Ltd. www.lacrossetechnology.com/support
If the above procedure does not work, please try the factory
can cause loss of connection between the remote sensor
or
factory restart.