Special adjustment for measuring and adjusting CO
The CO
can only be adjusted by a certified gas
2
technician with a calibrated CO
Caution: Converting the gas type can
only be done by a certified gas
technician with a calibrated CO
analyzer. Call CEC for conversion
instructions.
Caution: Adjustments must only be
carried out by authorized service
personnel only.
Caution: The appliance should always
be disconnected from the power supply
before any maintenance is carried out.
9.1
Adjusting the unit
Factory settings of this appliance are listed in table 7.
Further adjustment is only needed if optimal CO
is required in order to assure the minimum possible
CO
emissions. In this case a CO
2
9.1.1
CO
measuring port
2
B Loosen screw 1 (Fig. 44).
B Insert CO
analyzer into measuring port (Fig. 44,
2
pos. 1).
Fig. 44
1
Measuring point
9.1.2
Selecting adjustment mode
B ON/OFF switch in position OFF (0).
6 720 607 072 (16 January)
Special adjustment for measuring and adjusting CO2 levels
analyzer.
2
2
level
2
analyzer is required.
2
CO
adjustment at minimum gas flow (P1) - See
2
table 7.
Factory
setting
Nat. Gas
min. input
P1
9.00 %
min. input
P2
9.00 %
LP Gas
min. input
P1
10.80 %
min. input
P2
10.80 %
* Final reading must be confirmed with the front cover
on, CO
levels increase when the cover is installed.
2
Table 7
B Press "Program" key and turn ON/OFF switch to
position ON.
Fig. 45
LCD shows "P1" and the appliance is ready to be
adjusted.
B Open hot water tap.
The appliance will run constantly at minimum power
output and minimum water flow. This program step can
also be used to measure minimum output and minimum
water flow.
B Turn the screw in order to regulate the air-gas mixture
inside the ventilator until the CO
reached (Fig. 46, pos. 3).
CO
adjustment at maximum gas flow (P2) - See
2
table 7.
B Press
, until "P2" appears.
B Open water tap.
The appliance will run constantly at maximum power
output and maximum water flow. This program step can
also be used to measure maximum output and maximum
water flow.
B Turn the screw in order to regulate the air-gas mixture
inside the ventilator until the CO
reached (Fig. 46, pos. 3).
levels
2
Field settings
acceptable range
Nat. Gas
7.65 % to 10.35 %
8.1 % to 9.9 %
LP Gas
9.18 % to 12.42 %
9.72 % to 11.88 %
level required is
2
level required is
2