Summary of Contents for BURG-WACHTER TSE PRIME SET 5021 PINCODE
Page 1
Electronic door lock PRIME SET 5021 PINCODE SET 5022 FINGERSCAN SET 5013 E-KEY Assembly BURG-WÄCHTER KG and User Manual Altenhofer Weg 15 58300 Wetter Germany BA/MA TSE Set 5021,5022,5013 dp/sds 06 / 2016 www.burg.biz...
Thank you very much for your decision for the TSE Series 5000 electronic On button locking system by BURG-WACHTER. This system has been developed Activation of the keypad for entry of an opening code. and manufactured using the latest technical potential and satisfies high Enter button security requirements.
Page 3
TSE Set 5021 PINCODE TSE Set 5022 FINGERSCAN Technical data The electronic cylinder operates using a fingerscan. In addition, the cylinder The electronic cylinder operates using a 6-digit numeric code. Blocking times After 3 x wrong code is entered 1 minute, can be operated by entering the 6-digit numeric code, or also using the Optionally, the TSE 5103 E-KEY remote key can as well be used.
Description of menu functions Optical signalling Create User with E-Key submenu The optical signal in the form of a LED is incorporated in the knob on the – Activate the keypad using the The functions for the products TSE 5021 and TSE 5022 are described below. inner side of the door.
Page 5
Submenu Delete Submenu TSE Setup Registration of a keypad Using this menu, you can delete a user or an E-KEY. General system settings – Activate the keypad using the – Activate the keypad using the – Then press FUNC, the “Code Change” menu is displayed –...
Page 6
Setting the power saving mode Menu E-KEY synchronisation Info menu – Activate the keypad using the In this menu, the channel of the E-KEY can be adapted to the channel of the The version and serial number of the system are displayed using this –...
TSE E-KEY user instructions E-KEY battery replacement When gluing the holder plate on the colour sight protection film, the above described conditions relating to cleanliness of surfaces and firmness of the The E-KEY is intended as radio transmitter for releasing the cylinder. The 1 Open the housing cover by carefully forcing open the detent lugs.
Battery replacement for the keypad Cleaning instruction – Remove the housing cover on the bottom side by The surface finish of the keypad prevents adherence of impurities. Dust or loosing the 2 screws (Tx 8). dirt can be removed from the surfaces using a damp cloth. No alcohol-based detergents (spirit, SIDOLIN ®...
Page 9
Assembly manual for TSE Cylinder When installing the cylinder, proceed as follows: 5 Shift the inner knob over the shaft until attaining the required 1 Take a rough measurement of the door thickness (incl. fittings) dimension. Please make sure that the clearance between the rotary The installation of the TSE cylinder is described below.
Page 10
Replacement of batteries – knob (inner side) Emergency key function (outer side) Disposal 1 Using the attached hex key, loose the top locking screw on the cylinder Using the mechanical emergency key, you can provide access in case of Dear customer, cover.