Scott AIR-PAK 75 Operating & Maintenance Instructions page 38

Pressure-demand self-contained breathing apparatus (scba)
Table of Contents

Advertisement

CYLINDER REPLACEMENT CONTINUED...
Procedure B – WIREFRAME SCBA BACKFRAME
6. disengage the cylinder retention strap by lifting the latch plate up
and away from the backframe.
TRI-SLIDE
BUCKLE
RETENTION
STRAP
CYLINDER RETENTION USED ON WIREFRAME SCBA
7. grasp the cylinder below the band, push the locking tab below the
valve, lift the cylinder free from the bottom hook and remove. See
FIguRE 20
FIGURE 20
LOCKING TAB MECHANISM
WIREFRAME SCBA
8. Replace with a fully charged cylinder and valve assembly of the same
pressure rating. Slide the top of the cylinder upward under the band.
9. Engage the cylinder hanger in the hook at the bottom of the back-
frame.
FOR 4500 PSIg OR 5500 PSIg RESPIRATORS: IF A dIFFEREnT duRA-
TIOn OR dIAmETER CYLIndER IS uSEd, uSE THE TRI-SLIdE BuCKLE
TO AdJuST THE RETEnTIOn STRAP SO THAT IT PRESSES TIgHTLY
AgAInST THE CYLIndER WHEn THE LATCH ASSEmBLY IS FuLLY
EngAgEd. THE uSER SHOuLd nOT BE ABLE TO mOVE RETEnTIOn
STRAP uP And dOWn On THE CYLIndER WITH THEIR FIngERS
WHEn THE LATCH ASSEmBLY IS FuLLY CLOSEd.
10. Secure the cylinder in place by pushing the latch toward the back-
frame to lock the cylinder latch and fully engage the cylinder latch
assembly.
EnSuRE THAT THE CYLIndER IS SECuRELY HELd In PLACE On THE
BACKFRAmE BY THE CYLIndER RETEnTIOn ASSEmBLY. dO nOT
uSE EXCESSIVE FORCE TO LOCK THE LATCH mECHAnISm. IF THE
RETEnTIOn STRAP IS TOO TIgHT OR TOO LOOSE, uSE THE TRI-
SLIdE BuCKLE TO AdJuST THE RETEnTIOn STRAP EngAgEmEnT
LEngTH, THEn RE-ATTEmPT TO EngAgE THE LATCH ASSEmBLY.
P/N 595252-01 Rev. B 5/14
See FIguRE 19.
CYLINDER
LATCH
FIGURE 19
NOTE
NOTE
Continue with Step 11 below.
Page 38 of 48
LOCKING
TAB

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Air-pak

Table of Contents