  • Page 1 DSR-100PE SHANGHAI DIGITAL BALANCE ELECTRONIC CO., LTD version2.2 2020.10...
  • Page 2 INTRODUCTION Thank you for purchasing the DSR series label/receipt printing scale from SHANGHAI DIGITAL BALANCE ELECTRONIC CO., LTD The DSR series has many features and design features that facilitate operation and increase customer satisfaction. We believe that all your needs will be fully met. Please read and understand this manual.
  • Page 3 CATALOG 3.4 Document Editing (Mode + 151 ) ..............26 3.5 Product Edit Display Settings (Mode + 180 ) ..........26 Operational Warning..................I 3.6 Shortcut Key Settings ..................28 Precautions....................II 3.6.1 Prouduct Shortcut Editing (Mode + 152 ) ................... 28 1.
  • Page 4 OPERATIONAL WARNING Please follow the instructions below to operate the product to ensure product and personal safety. Before installation, it is important to c h e c k w h e t h e r the power supply Keep your fingers i n d i c a t e d b y t h e dry when inserting brand name matches...
  • Page 5 1. CONVENTIONAL PRECAUTIONS 1.1.1 ELECTRONIC SCALE SPECIFICATIONS Please follow the prompts to extend the life. Please avoid placing the product in the following locations: Maximum range 6 kg 15 kg If the temperature is too high or too low, direct sunlight, wet place; At the shared power supply, excessive vibration, dust, and moisture.
  • Page 6 1. CONVENTIONAL 1. CONVENTIONAL 1.1.2 RECEIPT PAPER SPECIFICATION 1.2.1 GLOBAL VIEW Length (x) range: 25 mm≤x≤200 mm Front view Width (y) range: 25 mm≤y≤58 mm Diameter (R) range: R≤80 mm Default paper width: 56 mm Side view Top view...
  • Page 7 1. CONVENTIONAL 1. CONVENTIONAL 1.3.1 Function keyboard 1.2.2 ROLL TRAY Open graph Shortcut keyboard 1.2.3 INTERFACE USB socket Operating keyboard Network cable jack Cash register slot Serial cable jack 1.2.4 DISPLAY Main/sub screen...
  • Page 8 1. CONVENTIONAL 1. CONVENTIONAL BASIC FUNCTION KEY Used to page up and down. Used to enter general numbers. Used to delete the wrong character entered. Used to add items, text, and left panel shortcuts when editing. Used to add spaces. Used for accumulating multiple transactions.
  • Page 9 2. BASIC OPERATION 2. BASIC OPERATION HORIZONTAL CALIBRATION 2.2.1 POLE MOUNTING Required parts Scale body, display pole, screw one. B a l a n c e instrument ·There are 4 feet in total. Adjusting the height can control the balance of the scale body, thereby reducing weighing errors.
  • Page 10 2. BASIC OPERATION 2. BASIC OPERATION 2.2.2 ROLL PAPER INSTALLATION 2.3.1 ON/OFF OPERATION When the power is turned on, make sure that the power Plug is Plugged into an AC outlet; at Turn on the printer by pulling the Put down the gray square buckle to the same time, make sure that the gray square button upwards;...
  • Page 11 2. BASIC OPERATION 2. BASIC OPERATION 2.3.2 BOOT MAP ZERO OPERATION * Zero: Zero the value before starting weighing to reduce the weighing error, and click to zero when no weight is placed on the weighing pan. TARE OPERATION * Tare: When the net weight of the product is required, the tare key can be used to remove excess weight.
  • Page 12 2. BASIC OPERATION 2. BASIC OPERATION Preset tare 2.7.1 USE [PLU] TO RETRIEVE GOODS Mode Bring out tare goods * Items entered in the scale can be added by "Mode" + "1", "5" and "0". ([Digital + project code key] / shortcut key), such as the item Weighing goods number is 1;...
  • Page 13 2. BASIC OPERATION 2. BASIC OPERATION 2.8.1 Accumulative operation 2.7.2 USE [SHORTCUT] TO RETRIEVE GOODS * Product shortcuts can be added via "Mode" + "1", "5" and "2"; the shortcut *The H key is the accumulation key, which is used for item counting. A keyboard can be set up to 3 layers, double-click or triple-click to get the second or single accumulation key can place orders for up to 50 commodities, and the third layer of quick items.
  • Page 14 2. BASIC OPERATION 2. BASIC OPERATION 2.8.2 CANCEL SINGLE ACCUMULATE DISCOUNT OPERATION * Set discount shortcut keys, you can set shortcut keys through "Mode" button + Cancel accumulation "1", "5", "3" / "1", "5", "4" / "1", "5", "5"; system default print button The code number is "10"...
  • Page 15 3. EDIT SETTINGS 3. EDIT SETTINGS VIEW ALL SETTINGS 3.2.1 SYSTEM TIME View settings system time Mode Tare Mode 100.Sale Report 222.BCD font 354.Current txn. no. 511.Shortcut key set When the scale is shipped from the factory, the time has been set. 512.Battery warning If necessary, it can be changed by 101.Group sale report...
  • Page 16 3. EDIT SETTINGS 3. EDIT SETTINGS 3.2.2.4 LARGE FILE NETWORK SEGMENT LENGTH 3.2.2.7 WLAN IP PORT AND TIMEOUT Mode Mode The large file network segment length The default wireless network port defaults to 4096 bytes. number is 2000. Long press “Mode” + “4” “4” “0” Long press the "mode"...
  • Page 17 3. EDIT SETTINGS 3. EDIT SETTINGS F1F2 is the first two digits of the PRODUCT SETTINGS label barcode and is set by the customer. The barcode format can be entered * Repeated operations for adding and modifying items, this book in 1-14 number, "2F"...
  • Page 18 3. EDIT SETTINGS 3. EDIT SETTINGS The unit price is displayed by DOCUMENT EDITING default in the product editing, and there is no special requirement for no change. The highest retail unit price is not Text Editor Mode displayed by default in the product editing, and generally no special After long press "Mode"...
  • Page 19 3. EDIT SETTINGS 3. EDIT SETTINGS The place of origin is not displayed Click “Print” to enter the next item. by default in the product editing. Enter the shortcut key number to Generally, there is no special be set on the numeric keypad. requirement and no modification is Double-click "Print"...
  • Page 20 3. EDIT SETTINGS 3. EDIT SETTINGS Long press "Mode" + "1", "5" and 3.7.1 LABEL SETTING "4", Set the F key. Click the “Page down” button to Label X coordinate editing 3.7.1.1 Mode set the “F2”, “F3”, “F4” and “F5” shortcut keys in order.
  • Page 21 3. EDIT SETTINGS 3. EDIT SETTINGS The Plu position is 0. Click “Page T h e l a b e l w e i g h t c a n n o t b e down” to view the next item. changed by default.
  • Page 22 3. EDIT SETTINGS 3. EDIT SETTINGS 3.7.3.2 Barcode font settings Mode 3.7.2 RECEIPT SETTING The bar code font size is 2mm by default and can be modified as Receipt print segment settings 3.7.2.1 needed. Mode Print segments up to 12 small items. 0 is the termination. -1 to -6 3.7.3.3 Predefined barcode settings Mode...
  • Page 23 3. EDIT SETTINGS 3. EDIT SETTINGS 3.7.5 TRANSACTION SETTINGS 3.7.4 PRINTER SETTINGS 3.7.5.1 Set transaction record auto clear threshold 3.7.4.1 Printer parameter settings Mode Mode Printer default label paper, if you The transaction record has a need to check the cash, please maximum of 4096 records by switch to receipt paper.
  • Page 24 3. EDIT SETTINGS 3. EDIT SETTINGS 3.7.7 PRINT PLU LIST 3.7.9 TRANSACTION CONTENT SETTINGS Print Plu List Mode Transaction content settings Mode The list of printed products can be By default, transaction content defined by yourself. The minimum does not allow for non-commodity number is 1 and the maximum is transactions, and you can modify it 9999999.
  • Page 25 3. EDIT SETTINGS 3. EDIT SETTINGS 3.7.11 MINIMUM EFFECTIVE WEIGHING 3.7.14 AUTOMATIC PRESET KEY FOR PLU Automatic preset key Minimum effective weighing Mode Mode The preset key assignment needs The default minimum effective to be entered in advance, and the w e i g h i n g w e i g h t f o r t r a d i n g default starting key is the shortcut operations is 40g.
  • Page 26 4. SALES REPORT 5. APPENDIX The default end time of the product SALES REPORT sales report export is the current time, please reset it. Sales Report Mode PRESET CODE COMPARISON TABLE Sales report export default start date is the same day, please reset. Code comparison table Sales report export default start date is 00:00:00, please reset.
  • Page 27 5. APPENDIX 5. APPENDIX 5 ( 50 x 42 ) 6 ( 50 x 42 ) 4 ( 40 x 32 ) SYSTEM ERROR Error code Error number Description Approach The system decides according Boot Error to the situation T h e s y s t e m a u t o m a t i c a l l y Boot Data Error formats the database and restarts The weighing platform removes...
  • Page 28 5. APPENDIX Error number Description Approach PLU Price Overflow Transaction Amount Overflow Hanging Transaction Empty Old Transaction not Exists Transaction Detail Too Many Transaction no Detail Transaction Detail Delete Fail Pay Illegal Pay Detail Too Many Price Illegal Price Change Not Allowed BCD Format Not Exists BCD Data Wrong Weight not Stable...