Table of Contents Getting Started ..................................3 1.1 About This Guide ..................................... 3 1.2 Factory Defaults ....................................... 3 1.3 Scanner Firmware Version ..................................3 1.4 Cradle Firmware Version ..................................3 Communication Interfaces ............................... 4 2.1 Bluetooth Scanner Setting ................................... 4 2.1.1 Connect with Bluetooth Cradle ..............................
Page 3
4.4 Clear All Prefix and Suffix .................................. 19 Symbologies ..................................20 5.1 General Setting ..................................... 20 5.1.1 Enable/Disable All Symbologies ............................... 20 5.2 Code 128 ......................................... 20 5.3 EAN-8 ........................................21 5.4 EAN-13 ........................................23 5.5 UPC-E ........................................26 5.6 UPC-A ........................................29 5.7 Interleaved 2 Of 5 ....................................
1 Getting Started 1.1 About This Guide This guide provides programming instructions for the SuperLead 2D Barcoder Reader. Users can configure the SuperLead 2D Barcoder Reader by scanning the programming barcodes included in this manual. 1.2 Factory Defaults Scanning the following barcode can restore the engine to the factory defaults.
2 Communication Interfaces 2.1 Bluetooth Scanner Setting Press the sanner`s button for 3s ,then it is powered on. 2.1.1 Connect with Bluetooth Cradle STEP1:Scan the barcode stuck at the bottom of the cradle, wait for connection. 2.1.2 Bluetooth Keyboard STEP1: Scan the barcode below to start a new connection. The scanner will be discoverable in 120s. Bluetooth keyboard STEP2:Set your personal laptop or tablet so it searches for other Bluetooth devices.
2.1.4 Country Keyboard Types Keyboard layouts vary from country to country. The default setting is U.S. keyboard. If your interface is Bluetooth Keyboard, scan the Keyboard Country barcode below to change this layout. US(default) Belgian Finnish_Swedish French German Italian Swiss_German British Danish Novwegian...
2.1.5 Convert Case Scan the appropriate barcode below to convert barcode data to your desired case. No Case Conversion (Default) Convert All To Upper Case Convert All To Lower Case 2.1.6 Input Method When a Bluetooth terminal connect with scanner, its virtual keyboard will disappear at once. You may need to scan the barcodes below to switch input language into English.
2.1.7 Power Setting Power Off 2.1.8 Standby time The scanner will power off if no operation is done within the standby time. 30min Never Power off 10min 2.2 Bluetooth Cradle/Dongle Settings Connect a scanner to Bluetoothcradle or dongle at first and then you can configure the cradle/dongle. 2.2.1 Cradle Factory Defaults Scan the barcode below can restore the cradle to factory defaults.
2.2.2 Baud Rate Baud rate is the number of bits of data transmitted per second. Set the baud rate to match the Host requirements. 2400 4800 9600 19200 38400 57600 115200 (default)...
2.2.3 Data Bit & Parity Check & Stop Bit None Parity /7 Data Bits/1 Stop Bit None Parity /8 Data Bits/1 Stop Bit (default) Even Parity /8 Data Bits/1 Stop Bit None Parity /7 Data Bits/2 Stop Bits Even Parity /7 Data Bits/2 Stop Bits Even Parity /7 Data Bits/1 Stop Bit Odd Parity /7 Data Bits/1 Stop Bit Odd Parity /8 Data Bits/1 Stop Bit...
2.2.4 USB Interface When you connect cradle to the Host via a USB Cable, you can enable the USB HID-KB feature by scanning the barcode below. Then cradle’s transmission will be simulated as keyboard input. The Host receives keystrokes on the virtual keyboard. It works on a Plug and Play basis and no driver is required.
2.2.7 Asynchronous transfer mode Note: Data is stored when Bluetooth disconnected and will upload automatically when reconnect. 2.2.8 Mass storage mode Note: Data is always stored. Upload all stored data Count total amount of uploaded data Clear stored data...
3 General Configuration 3.1 Trigger Mode If the Trigger Mode is enabled, you could activate the scanner by providing an external hardware trigger, or using a serial trigger command. When in manual trigger mode, the scanner scans until a barcode is read, or until the hardware trigger is released.
3.3 Inverse color OFF (Default) Only Inverse ON Inverse And Normal Both ON 3.4 Illumination Manual Trigger Mode Illumination setting for 22XX/24XX/26XX BLE series. Illumination Level 4 (Default) Illumination Level 3 Illumination Level 2 Illumination Level 3...
4.2 Add Prefix Set Custom Prefix Save Not Save To set a customer prefix, scan the Set Custom Prefix barcode and the numeric barcodes which representing the hexadecimal values of a desired prefix, and then scan the Save barcode. Refer to Appendix 2: ASCII Table for hexadecimal values of characters.
4.3 Add Suffix Set Custom Suffix Save Not Save To set a customer suffix, scan the Set Custom Suffix barcode and the numeric barcodes which representing the hexadecimal values of a desired suffix, and then scan the Save barcode. Refer to Appendix 2: ASCII Table for hexadecimal values of characters.
5 Symbologies 5.1 General Setting 5.1.1 Enable/Disable All Symbologies If the Disable All Symbologies feature is enabled, the engine will not be able to read any non-programming barcodes except “the barcodes. Restore All Factory Defaults” Enable All Symbologies Disable All Symbologies 5.2 Code 128 Enable/Disable Code 128 Enable Code 128 (Default)
Message Length Message length can be set to the maximum value or minimum value. The value between the maximum and the minimum is valid. The maximum value and minimum value can be set using “Programming Command”. Please check the programming command guide for the detail. Code 128 max length command: 020A03.
Page 23
Add-On Code An EAN-8 barcode can be augmented with a two-digit or five-digit add-on code to form a new one. In the examples below, the part surrounded by blue dotted line is an EAN-8 barcode while the part circled by red dotted line is add-on code. Enable 2-Digit Add-On Code Disable 2-Digit Add-On Code (Default) Enable 5-Digit Add-On Code...
Add-On Code Required EAN-8 Add-On Code Required EAN-8 Add-On Code Not Required (Default) ENA/JAN-8 Addenda Separator When this feature is enabled, there is a space between barcode and addenda. When this feature is disabled, there is no space. Enable ENA/JAN-8 Addenda Separator (Default) Disable ENA/JAN-8 Addenda Separator UPC 5.4 EAN-13 Enable/Disable EAN-13...
Page 26
EAN-13 Add-On Code Not Required (Default) ENA/JAN-13 Addenda Separator When this feature is enabled, there is a space between barcode and addenda. When this feature is disabled, there is no space. Enable ENA/JAN-13 Addenda Separator (Default) Disable ENA/JAN-13 Addenda Separator ISBN Translate When enable this feature and is scanned, EAN-13 Book land symbols are translated into their equivalent ISBN number format.
Page 28
UPC-E0 Expand UPC-E0 expand expands the UPC-E code to the 12 digits, UPC-A format. Enable UPC-E0 Expand Disable UPC-E0 Expand (Default) UPC-E0 Addenda Required When required is scanned, the scanner will only read UPC-E barcodes that have addenda. Enable UPC-E0 Required Disable UPC-E0 Required (Default) UPC-E0 Addenda Separator Enable UPC-E0 Separator (Default)
Page 29
UPC-E0 Number System The number system digit of UPC symbol is normally transmitted at the beginning of the scanned data, but the unit can be programmed so it will be not transmitted. Enable UPC-E0 Number System (Default) Disable UPC-E0 Number System UPC-E0 Addenda Enable 2 Digit Addenda Disable 2 Digit Addenda (Default)
5.6 UPC-A Enable/Disable UPC-A Enable UPC-A (Default) Disable UPC-A UPC-A Check Digit Enable UPC-A Check Digit (Default) Disable UPC-A Check Digit UPC-A Addenda Required When required is scanned, the scanner will only read UPC-A barcodes that have addenda. Enable UPC-A Required Disable UPC-A Required (Default)
Page 31
UPC-A Addenda Separator Enable UPC-A Separator (Default) Disable UPC-A Separator UPC-A Number System The number system digit of UPC symbol is normally transmitted at the beginning of the scanned data, but the unit can be programmed so it will be not transmitted. Enable UPC-A Number System (Default) Disable UPC-A Number System...
5.7 Interleaved 2 Of 5 Enable/Disable Interleaved 2 Of 5 Enable Interleaved 2 Of 5 (Default) Disable Interleaved 2 Of 5 Message Length Message length can be set to the maximum value, minimum value. The data between the maximum and the minimum is valid. The maximum value and minimum value can be set using Programming Command.
5.8 Matrix 2 Of 5 Enable/Disable Matrix 2 Of 5 Enable Matrix 2 Of 5 Disable Matrix 2 Of 5 (Default) Message Length Message length can be set to the maximum value, minimum value. The value is valid between the maximum and the minimum.
5.9 Industrial 2 Of 5 Enable/Disable Industrial 2 Of 5 Enable Industrial 2 Of 5 Disable Industrial 2 Of 5 (Default) Message Length Message length can be set to the maximum value, minimum value. The value is valid between the maximum and the minimum.
5.10 Code 39 Enable/Disable Code 39 Enable Code 39 (Default) Disable Code 39 Transmit Start/Stop Character Transmit Start/Stop Character Do Not Transmit Start/Stop Character (Default) Code 39 Check Character No Check Char (Default) Validate And Transmit Validate No Transmit...
Page 37
Code 39 Append This function allows the scanner to append several Code 39 barcode data together before transmitting to host. When the scanner encounters a Code 39 barcode with append character (ex. Space character), it buffers the data until it reads a Code 39 barcode which does not have append character.
5.11 Coda Bar Enable/Disable Coda Bar Enable Coda Bar (Default) Disable Coda Bar Message Length Message length can be set to the maximum value, minimum value. The data between the maximum and the minimum is valid. The maximum value and minimum value can be set using Programming command. Please check the programming command guide for the detail.
Page 39
Transmit Start/Stop Character Transmit Start/Stop Character Do Not Transmit Start/Stop Character (Default) Coda bar Check Character No Check Char (Default) Validate And Transmit Validate No Transmit...
5.12 Code 93 Enable/Disable Code 93 Enable Code 93 (Default) Disable Code 93 Message Length Message length can be set to the maximum value, minimum value. The data between the maximum and the minimum is valid. The maximum value and minimum value can be set using Programming command. Please check the programming command guide for the detail.
5.13 GS1-128 Enable/Disable GS1-128 Enable GS1-128 (Default) Disable GS1-128 Message Length Message length can be set to the maximum value, minimum value. The data between the maximum and the minimum is valid. The maximum value and minimum value can be set using Programming command. Please check the programming command guide for the detail.
5.15 PDF 417 Enable/Disable PDF 417 Enable PDF 417 (Default) Disable PDF 417 Enable/Disable Micro PDF 417 Enable Micro PDF 417 Disable Micro PDF 417 (Default) Message Length Message length can be set to the maximum value, minimum value. The data is valid between the maximum and the minimum.
5.16 QR Code Enable/Disable QR Code Enable QR Code (Default) Disable QR Code Message Length Message length can be set to the maximum value, minimum value. The data is valid between the maximum and the minimum is valid. The maximum value and minimum value can be set using Programming command. Please check the programming command guide for the detail.
5.17 Data Matrix Enable/Disable Data Matrix Enable Data Matrix (Default) Disable Data Matrix Message Length Message length can be set to the maximum value, minimum value. The data is valid between the maximum and the minimum. The maximum value and minimum value can be set using Programming command. Please check the programming command guide for the detail.
5.18 Maxi code Enable/Disable Maxi code Enable Maxi Code Disable Maxi Code (Default) Message Length Message length can be set to the maximum value, minimum value. The data is valid between the maximum and the minimum. The maximum value and minimum value can be set using Programming command. Please check the programming command guide for the detail.
5.19 Aztec Enable/Disable Aztec Enable Aztec (Default) Disable Aztec Message Length Message length can be set to the maximum value, minimum value. The data is valid between the maximum and the minimum. The maximum value and minimum value can be set using Programming command. Please check the programming command guide for the detail.
6 Appendix 6.1 Appendix 1: AIM ID Table Symbology AIM ID Remark Standard EAN-13 EAN-13 EAN-13 + 2/5-Digit Add-On Code Standard EAN-8 EAN-8 ]E4… ]E1… EAN-8 + 2-Digit Add-On Code ]E4… ]E2… EAN-8 + 5-Digit Add-On Code Standard UPC-E UPC-E UPC-E + 2/5-Digit Add-On Code Standard UPC-A UPC-A...
Page 49
Standard Codebar Codebar Transmit check digit after parity check Do not transmit check digit after parity check Code 93 Standard Code 93 One check digit MOD11; transmit check digit Two check digits, MOD11/MOD11; transmit check digit Code 11 Do not transmit check digit after parity check No parity check GS1-DataBar (RSS) Standard GS1-DataBar...
Page 50
QR Code 2005,ECI excluded,FNC1 is the 2nd character after the start character QR Code 2005, ECI included, FNC1 is the 2nd character after the start character Reference: ISO/IEC 15424:2008 Information technology – Automatic identification and data capture techniques – Data Carrier Identifiers (including Symbology Identifiers).