Mitsubishi Electric PKA-A24KA8 Service Manual page 46

Table of Contents

Advertisement

13-5-2. PAR-SL101A-E
Fig. 1
Fig. 2
Fig. 3
Fig. 4
TCH115A
1. Going to the function select mode
Press the
button between of 5 seconds.
(Start this operation from the status of remote controller display turned off.)
[CHECK] is lit and "00" blinks. (Fig. 1)
Press the
button to set the "50".
Direct the wireless remote controller toward the receiver of the indoor unit and
press the
button.
2. Setting the unit number
Press the
button to set unit number
Direct the wireless remote controller toward the receiver of the indoor unit and
press the
button.
3. Select a mode
Press the
button to set Mode number
Direct the wireless remote controller toward the receiver of the indoor unit and
press the
button.
Current setting number:
4. Selecting the setting number
Use the
button to change the Setting number
Direct the wireless remote controller toward the receiver of the indoor unit and
press the
button.
5. To select multiple functions continuously
Repeat select
and
to change multiple function settings continuously.
6. Complete function selection
Direct the wireless remote controller toward the sensor of the indoor unit and
press the
button.
Note: Be sure to write down the settings for all functions if any of the initial
settings has been changed after the completion of installation work.
46
. (Fig. 2)
. (Fig. 3)
1=1 beep (1 second)
2=2 beep (1 second each)
3=3 beep (1 second each)
. (Fig. 4)

Hide quick links: