How To Check Fault Symptom; Power - Samsung UN HU6900F Series Service Manual

Table of Contents

Advertisement

4. Troubleshooting

4-2. How to Check Fault Symptom

4-2-1. NO Power
Note
Refer to the next page to check the location such a CN201 or IC201 SVC Manual mentioned.
The LEDs on The front panel do not work when connecting The power cord.
Symptom
The SMPS relay does not work when connecting The power cord.
The units appears to be dead.
The IP relay or the LEDs on the front panel does not work when connecting the power cord if the cables are
improperly connected or the Main Board or SMPS is not functioning. In this case, check the following:
Check the internal cable connection status inside the unit.
Major
Check the fuses of each part.
checkpoints
Check the output voltage of SMPS.
Replace the Main Board.
-
Check 'Power input of Main Ass'y' ?
-
-
Diagnostics
-
Check 'Power IC output of Main Ass'y' ?
-
-
-
-
Check Input power of 'T CON Board' ?
-
4-4
All manuals and user guides at all-guidesbox.com
Power indicator LED is on?
Yes
Check the backlight on,
when 24p cable unconnected ?
Yes
Check 'Stand-By 5V' ?
BD213 : A5.3V
Yes
BD206~BD208 : B13VS
BD200~BD205 : B13V
BD228 : B5V
Yes
IC209 : A3.3V
BD2208~BD2212 : B2.5V /
L204 : B5V
BD1900, BD2206 : B3.3V /
BD2203~BD2205 : B1.5V
BD2214~BD2216 : B1.12V
Yes
F1(T-CON) : PANEL_13V_PW
No
Check the power cord connection.
No
No
Replace 24p Power Cable.
Replace Main Power Ass'y.
No
No
Change the Main Ass'y.
Reconnect or Change.
No
the LVDS cable.