Download Print this page

Whisper Power 40290316 Installation Manual page 4

Wbm link to nmea 2000

Advertisement

nstallation and setup guide
4
WBM Link to NMEA 2000
4
4.
Connecting the interface box
The WBM Link to NMEA 2000 interface forms a bridge between WBM Link
enabled devices and an NMEA 2000 network. Currently it only supports the
WBM Modular Smart Shunt ba�ery monitor.
The interface presents the following parameters on the NMEA 2000 network.
unting screws
Battery monitor
active shunt
Only the parameters of ba�ery bank 1 are available.
Changing of device- and ba�ery instance is fully supported by this interface,
allowing multiple WBM Modular Smart Shunt on the NMEA 2000 network, with
each WBM Modular Smart Shunt having its own WBM Link to NMEA 2000
interface. A proper NMEA 2000 network management tool is needed to change
device- and ba�ery instance. Such a tool is not provided by us.
QLINK
It is assumed that the user of this device has a good understanding of the NMEA
2000 standard.
5
5.
NMEA 2000 Interface Standard
The NMEA 2000 standard contains the requirements of a serial data
communica ons network to inter-connect marine electronic equipment on
vessels. It is mul -master and self-configuring, and there is no central network
controller. Equipment designed to this standard will have the ability to share data,
including commands and status with other compa ble equipment over a single
channel. It is based on CAN (Controller Area Network). NMEA 2000 is a registered
Trademark of the Na onal Marine Electronics Associa on.
3
Introduction
Connecting the interface box
Voltage
§
Current
§
Amp-Hours removed
§
State-of-Charge
§
Time Remaining
§
Temperature
§
Ba�ery Capacity
§
Ba�ery Type
§
Nominal Voltage
§
NMEA 2000 Interface Standard
NMEA 2000 network
backbone
M12 male cable connector. Insert in
male T-piece connector and gently
turn plastic ring clockwise for locking
M8 female cable connector. Insert in
male chassis connector and gently
turn plastic ring clockwise for locking
LED conditions:
flashing orange
flashing green
flashing red
Additional WBM Link port for connecting other WBM
Link accessories (see notes in chapter 10 for
additional information)
waiting for WBM Link connection
normal operation / data indicator
Communication error
2000 standard
5
N
The NMEA 20
communica o
vessels. It is m
controller. Equ
including com
channel. It is b
Trademark of
6
Su
The following
sent on reque
PGN
Na
59392
ISO
60160
ISO
60416
ISO
60928
ISO
126208
NM
126464
PG
126993
He
126996
Pro
126998
Co
127502
Sw
127506
DC
127508
Ba
127513
Ba
See backside

Advertisement

loading