Maintenance - Simpson PRO3800PW Instruction Manual

Professional pressure washer
Table of Contents

Advertisement

WARNING: Risk of burn hazard. When performing maintenance, you may
be exposed to hot surfaces, water pressure or moving parts that can cause
serious injury or death.
WARNING: Risk of fire hazard. Always disconnect, spark plug wire,
let the engine cool and release all water pressure before performing any
maintenance or repair. The engine contains flammable fuel. Do not smoke or
work near open flames while performing maintenance.
To ensure efficient operation and longer life of your pressure washer, a routine
maintenance schedule should be prepared and followed. If the pressure washer is
used in unusual conditions, such as high-temperatures or dusty conditions, more
frequent maintenance checks will be required.
ENGINE
Consult the Engine Owner's Manual for the manufacturer's recommendations
for any and all maintenance. NOTE: The engine drain plug is located at the rear of
the unit.
PUMP (FIG. 15)
NOTE: The Pump was filled with oil at the factory. The preferred oil is SIMPSON
Premium Pump Crankcase Oil. If this oil is not available, an SAE 15W-40 oil may
be used. Change the pump oil after the first 50 hours of operation and every 100
hours thereafter, or every 3 months.
TO CHECK OIL
The oil level should come to the dot in the middle of
the sight glass (AA).
HOW TO CHANGE PUMP OIL
1.
Loosen pump oil fill plug (BB).
2.
Place a container under the pump oil drain plug
(CC).
3.
Remove pump oil drain plug.
4.
After oil is drained, replace pump oil drain plug.
Tighten securely.
5.
For AAA
pumps, refill using SIMPSON
TM
oil is not available, an SAE 15W-40 oil may be used.
For CAT Pumps
6.
Replace pump oil fill plug and tighten securely.
If there is a problem with the pump contact us at www.simpsoncleaning.com
*** CAT PUMPS
CONNECTIONS
Connections on pressure washer hoses, gun and spray wand should be cleaned
regularly and lubricated with light oil or lithium grease to prevent leakage and
damage to the o-rings.
NOZZLE CLEANING (FIG. 16)
If the nozzle becomes clogged with foreign materials, such as dirt, excessive
pressure may develop. If the nozzle becomes partially clogged or restricted, the
pump pressure will pulsate. Clean the nozzle immediately using the nozzle kit
supplied and the following instructions:

MAINTENANCE

***, refill using a non-detergent hydraulic oil (ISO 68).
®
is a registered trademark of Diversified Dynamics Corporation.
®
15
Premium Pump Crankcase Oil. If this
®
18- ENG
®
BB
AA
CC

Advertisement

Table of Contents
loading

Table of Contents