Toshiba AW-G9930S Service Manual page 18

Fully automatic washing machine
Table of Contents

Advertisement

(3) Electrical part failure diagnosis (check with inspection mode)
No.
PART
1
Motor
Water intake valve
Drain valve motor
2
Drain valve motor
(Wind signal)
3
Revolution sensor
4
Water level sensor
5
Lid switch
All manuals and user guides at all-guides.com
~
Inspection mode 1
5
Check voltage at locations to be
tested under standby status.
Do they show 220 V*?
Yes
With machine operated, check voltages at
locations to be tested.
Do they change from AC 220 V*→0 V?
Change
*: It should be each rated voltage.
Inspection mode 6
Check voltage accross CN1 black
and CN3 red under standby status.
Does it show AC 220 V*?
Yes
Check above voltage after wind-up
completion.
Does it change from AC 220 V* to 0 V?
Change
*: It should be each rated voltage.
Inspection mode 7
Check voltage across CN6 pink
and CN6 light green.
Does it show DC 5 V?
Yes
Rotates pulsator with hand and check voltage
across CN1 black and CN4 light green.
Does it change from DC 5 V ← → 0 V or vice versa?
Inspection mode 8
Do all water level indicators turn off
with no water filled on tub?
All turn off
Does water level indicator show a level
with water filled on the tub?
(For water level indication and water
level, refer to below)
Indication is apt to low
Water level indication vs. water level
Water level height
Water level
51 L
approx. 353 mm
41 L
approx. 298 mm
32 L
approx. 228 mm
19 L
approx. 138 mm
10 L
approx. 73 mm
Inspection mode 9
Check voltage across CN6 pink
and CN6 blue.
Does it show DC 5 V?
Yes
Does voltage across CN6 pink and CN6 blue change
from DC 5 V to 0 V when the lid is opened or closed?
Failure diagnosis method
Associated electrical parts may be
No
:
failure, or lead unit connector
disconnected or breakdown.
No change
:
Program timer failure
Inner lock of motor and drain valve
:
etc. or lock of drive assembly.
Drain valve motor internal lead
No
:
breakdown, or lead unit connector
disconnected, or leads breakdown.
No change
:
Drain valve motor failure
Program timer failure
:
No
Program timer failure
:
No change
Change
Sensor case assembly or lead unit
:
connector disconnected, lead
breakdown.
Either one of them
Is 3P connectors of
turns on
water level sensor
:
disconnected?
Indication is
Water level sensor
apt to high
:
part failure or program
timer failure.
Check air tube disengaged, broken
:
down, folded, foreign matter
clogged, water inversion onto air
trap, etc.
220 V
No
Program timer failure
:
Change
Lid switch, or lead unit connector
No change
disconnected, breakdown.
:
– 17 –
Disconnected
Connect
:
Connected
No abnormality