  • Page 1 INSTRUCTIONS FOR INSTALLATION AND USE FLS4G - FRS4G - FLS6G - FRS6G FLRS6G- FLS8G - FRS8G - FLRS8G GAS FRYTOP FOR RESIDENTIAL AND PROFESSIONAL USE...
  • Page 2 14. In case of failure or malfunction, turn the appliance off, close the gas supply valve and do not attempt to carry out any repairs, which must be done exclusively by an authorized service center. Request the use of original spare parts only. Failure to comply with the above recommendations may compromise the appliance’s safety. Officine Gullo...
  • Page 3: Table Of Contents

    WHAT TO DO IN THE EVENT OF A BREAKDOWN ..............13 OBSERVATIONS AND ADVICE ....................14 PROCEDURE TO FOLLOW IF THE APPLIANCE IS NOT GOING TO BE USED FOR SOME TIME ..14 MAINTENANCE (only for qualified personnel) ................14 INSTRUCTIONS FOR DISCHARGING GAS EMISSIONS ............14 Officine Gullo...
  • Page 4: Installation Manual

    INSTALLATION MANUAL Fig. A/1 F...S4G 73 cm 70 cm 3 cm 4 cm (1/2") (1/2") 10 cm 20 cm 67 cm 40 cm G. Gas Connection ISO 7-1 R1/2GM LEGEND Gas connection/Connessione Gas 40 cm Officine Gullo...
  • Page 5 Fig. A/2 F...S6G 73 cm 70 cm 3 cm 4 cm (1/2") (1/2") 10 cm 20 cm 67 cm 60 cm G. Gas Connection ISO 7-1 R1/2GM LEGEND Gas connection/Connessione Gas 60 cm Officine Gullo...
  • Page 6 Fig. A/3 F...S8G 73 cm 70 cm 3 cm 4 cm (1/2") (1/2") 10 cm 20 cm 67 cm 80 cm G. Gas Connection ISO 7-1 R1/2GM LEGEND Gas connection/Connessione Gas 80 cm Officine Gullo...
  • Page 7 Fig. B Knob Pilot Control Panel clamp Lighting spark plug Piezoelectric device Injector Valve 10. Clamp Gas pipes 11. Drip pan Thermocouple Officine Gullo...
  • Page 8: Declaration Of Compliance

    DECLARATION OF COMPLIANCE This appliance is manufactured by OFFICINE GULLO S.r.l Headquarters and factory Via Della Torricella 29, Antella, Bagno a Ripoli 50012 Florence - Italy Tel. +39 055 65 60 3324 +39 055 62 18 07 officinegullo.com | info@officinegullo.com The manufacturer declares that the appliances are compliant with the prescriptions of the EEC norm 2009/142.
  • Page 9: Checking For Adequate Ventilation

    All our appliances undergo careful testing: the type of gas, the operating pressure and the category are indicated on the data plate. Officine Gullo...
  • Page 10: Checking Heat Output

    (see table of “burners” technical data). CHECKING PRIMARY AIR IN MAIN BURNERS All burners are provided with special injectors which do not require regualtion of the primary air. Officine Gullo...
  • Page 11: Table Of Burners Techincal Data

    Examine the flame of the pilot burner; it must lap the thermocouple and be blue, otherwise examine the nozzle of the pilot burner. • Check the lighting and flame of the main burner. • We urge the user to follow the instructions when using the appliance. Officine Gullo...
  • Page 12: Maintenance

    Push and turn the knob into position “0”. This command blocks the gas supply to both the main burner and the pilot burner. DRIP PAN The drip pan must be checked regularly and emptied before getting full. In any event, the pan must be cleaned after switching off the appliance. Officine Gullo...
  • Page 13: Cleaning And Maintenance

    All the brushed steel surfaces should be cleaned using degreasing products or products specifically designed to be used on steel and, where necessary, extra-fine steel wool or extra-thin sandpaper. WHAT TO DO IN THE EVENT OF A BREAKDOWN Turn off the gas tap and notify the after sales service. Officine Gullo...
  • Page 14: Observations And Advice

    Supplying the appliance with gas again must only be possible manually. NATURAL DISCHARGE NATURAL DISCHARGE FORCED DISCHARGE FORCED DISCHARGE Fig.1 Fig.1 Fig.2 Fig.2 1. Extractor hood 1. Extractor hood 1. Extractor hood 1. Extractor hood 2. Interlocking 2. Interlocking Officine Gullo...
  • Page 15 FORCED DISCHARGE Fig. 3 Fig. 4 1) Anti-wind (blow back) chimney 1. Extractor hood 2. Interlocking Type “B11” appliances are supplied upon request with chimney or chimney and anti-wind (blow back) device to be assembled and delivered separately. Officine Gullo...
  • Page 16 international V 1.7 - 11.20 Tel. +39 055 656 0324 | info@officinegullo.com Via Della Torricella 29, Antella, Bagno a Ripoli - 50012 Florence - Italy OFFICINEGULLO.COM...